To set a channel to a particular range, read the switch positions as UP or DN (down) from left to right in the row beside the range you desire.

For example, the ±5V range is: UP>DN>DN>UP>DN.

3.6 Installing the CIO-DAC## in the Computer

Turn the power off.

Remove the cover of your computer. Please be careful not to dislodge any of the cables installed on the boards in your computer as you slide the cover off.

Locate an empty expansion slot in your computer.

Push the board firmly down into the expansion bus connector. If it is not seated fully it can fail to work and could short circuit the PC bus power onto a PC bus signal. This could damage the motherboard in your PC as well as the CIO-DAC##.

3.7 Cabling to the CIO-DAC##

The CIO-DAC## connector is accessible through the PC/AT expansion bracket. The connector is a standard 37-pin male connector. A mating female connector, such as the C37FF-2, is available from OMEGA.

Several cabling and screw termination options are available from OMEGA.

DFCON-37

D connector, D shell and termination pins to

 

construct your own cable

C37FF-2

2-foot (and longer) ribbon cable with 37 pin D

 

connectors

C37FFS-5

5-foot shielded round cable with molded ends

 

housing 37-pin connectors. Also available in 10-ft.

 

length.

CIO-MINI37

Simple, 40-position 4”X4” screw terminal board

CIO-TERMINAL

Full featured 4 x 16 in. screw terminal board with

 

prototyping and interface circuitry

3.8 Testing the Installation

You can test the installation of the CIO-DAC## using InstaCal. Select the Test option to vary the output voltages and monitor them with a Volt Meter.

6

Image 10
Contents CIO-DAC16 CIO-DAC08 HM CIO-DAC##.lwp Table of Contents This page is blank Software Installation IntroductionInitial Board Setup Hardware InstallationSelecting the Base Address HEX Function Range Wait State Jumper OFFAnalog Output Range Switches Simultaneous Update JumperTesting the Installation Installing the CIO-DAC## in the ComputerCabling to the CIO-DAC## Signal Connection Connector Diagram Connector CIO-DAC16Register Architecture Control & Data RegistersMSB Output Transfer Functions Specifications Analog OutputEnvironmental For your notes EC Declaration of Conformity Omega Engineering Inc One Omega Drive Stamford, Ct 800