JVC GM-F470S, GM-F520S, GM-F420S specifications Setting

Page 19

Setting

Make the settings for the motion sensor on “MOTION SENSOR” of the main menu.

• For the menu operation procedure, see page 12.

NOTE

• While the function is controlled by the motion sensor, only the external control by the MAKE system can

control that function. You cannot use other external control and the buttons on the remote control and the

monitor.

<MAIN MENU>

PICTURE SETTING

SIZE SETTING

SIGNAL SETTING

AUDIO SETTING

FUNCTION SETTING

MOTION SENSOR

LANGUAGE:ENGLISH

AUTO POWER : OFF

VOLUME : ON

VALUE : +20

INPUT SELECT: OFF

INPUT : DVI SWAP DISPLAY: OFF BACK LIGHT : ON

VALUE : +10 SUSTAIN TIME : 40min. reset

ON

OFF

The status of the monitor returns automatically to that before detecting human as the time set on “SUSTAIN

 

TIME” passed without another detection. The monitor turns off when “AUTO POWER” is “ON”.

When “SUSTAIN TIME” is set to “0 min.”, the main unit takes the actions set for about 1 second. You can use

 

the setting for checking the operations and detection area of the motion sensor.

If you set “SUSTAIN TIME” to “0 min.” while “AUTO POWER” is set to “ON”, the monitor repeatedly turns on and off, making further menu operations impossible. In this case, unplug the motion sensor from the monitor, open the menu, and change the setting of “AUTO POWER” to “OFF”.

When you want to check the function of the motion sensor by setting “SUSTAIN TIME” to “0 min.”, it is recommended to select “ON” only for “VOLUME” or “BACK LIGHT”.

The information from the motion sensor can be used on the external control equipment connected through the RS-232C terminal to control the main unit.

Set all “MOTION SENSOR” settings to “OFF” when processing the information from the sensor on the external control equipment. Consult your dealer for more information.

SELECT : 5 ∞ ADJUST : 2 3 EXIT : MENU

Item

To do

 

Setting value

AUTO POWER

To turn on the monitor when the motion sensor detects the

 

ON, OFF

 

motion of human, select “ON.” The monitor automatically

 

 

 

turns off when the sensor detect no human motion for a

 

 

 

certain period of time.

 

 

VOLUME

To change the volume level when the motion sensor detects

 

ON, OFF

 

the motion of human, select “ON.”

 

 

VALUE

Adjust the volume level when “VOLUME” above is “ON.”

 

00 += 30

INPUT SELECT

To change the input when the motion sensor detects the

 

ON, OFF

 

motion of human, select “ON.”

 

 

INPUT

Select the input when “INPUT SELECT” above is “ON.”

 

VIDEO, RGB, DVI

SWAP DISPLAY

To switch the main display and sub display of the Dual

 

ON, OFF

 

Display when the motion sensor detects the motion of

 

 

 

human, select “ON.”

 

 

BACK LIGHT

To change the brightness of the back light when the motion

 

ON, OFF

 

sensor detects the motion of human, select “ON.”

 

 

VALUE

Adjusts the brightness level when “BACK LIGHT” above is

 

–20 += +20

 

“ON.”

 

 

SUSTAIN TIME

Set the duration of the status set above when human is

 

0 min. += 60 min.

 

detected.

 

 

reset

Restore the default setting for the items in “MOTION SENSOR.”

 

19

Image 19
Contents GM-F520S GM-F470S GM-F420S Power Connection Safety PrecautionsHow to replace the fuse Cabinet MaintenanceDear Customer ScreenTo prevent an accidental fall InstallationPrecautions How to attach the standParts Identification Remote controlMonitor Audio 1 OUT ConnectionsAudio 2 OUT Audio output terminals Video input terminalsAudio input terminals Video output terminalsGND Available signalsVideo signals Video RGB DVI-DRGB DVI-D Computer signalsDaily Operations Controlling only the monitor with specified ID Selecting the picture modeDisplaying the current status Activating the Dual DisplaySelect an item by pressing 5 ∞ , then press Menu OperationDisplay the menu Menu Configuration-MAIN Menu Dual Display Color SystemMulti Display Multi SizeMenu Configuration-SET-UP Menu Tuesday Wednesday Subnet Mask Default Gateway DNS ServerPresent Time Program SET Sunday MondayUsing the timer Setting the Security LockOutline of the motion sensor Installation and connectionAngle of the sensor Setting Remote in SEL CNT. RJ45 OUT About the external controlUsing the serial communication Operation How to Use External ControlUsing the MAKE/TRIG. system To assign the functions to the pin terminalsTo join the network Using the LAN systemOperation on the web browser General-Purpose Control Motion Sensor SettingFunction Aspect Direct Selection Full Troubleshooting Following are not malfunctions Symptom Probable cause and corrective actionSetting Please Enter Pass IDTEMP. Over Self-diagnostic indicationIf the trouble still persists, follow the procedure below Self-diagnostic Report SheetGeneral SpecificationsMotion sensor DimensionsInput/output terminals GM-F520SRear view GM-F470SGM-F420S Top view Front viewPage 0209TKH-MW-MT Victor Company of Japan, Limited