JVC GM-F520S Outline of the motion sensor, Installation and connection, Angle of the sensor

Page 18

Using the Motion Sensor

18

 

 

Outline of the motion sensor

By connecting the supplied motion sensor, you can set the monitor to perform the specified operation when the sensor detects the motion of human around the monitor. The status of the monitor returns automatically to that before detecting human if the sensor does not detect any motion for a certain period of time.

The sensor is the pyroelectric infrared-ray-detection type.

Operations controlled by the motion sensor

(1)Turning the monitor on/off When the sensor detects the motion of human around the monitor, the monitor turns on.

(2)Changing the volume level When the sensor detects the motion of human around the volume level changes to the specified level.

(3) Changing the input

When the sensor detects the motion of human around the monitor, the

 

input changes.

(4)Switching the main display When the sensor detects the motion of human around the monitor with

and sub display for Dual the Dual Display activated, the main display and sub display switch.

Display

(5)Changing the backlight When the sensor detects the motion of human around the brightness

brightness

level changes to the specified level.

Example: When the setting (4) above is activated...

Installation and connection

The motion sensor can be attached to either of 24 screw holes on the main unit (5 screw holes on the top and bottom, and 7 on the right and left side). Choose an appropriate position according to the installation place of the monitor. The cable length of the sensor is about 1.5m (5 feet).

CAUTION

• Firmly attach the sensor to prevent the sensor from falling.

GM-F470S/GM-F420S

GM-F520S

Not available when the monitor is

The bottom and the right side have screw holes at the same positions

installed using the supplied stand.

as those on the top and the right side, respectively.

Displaying A on the main window and B on the sub

Detection range of the sensor

about

 

about 80°

 

 

5 m

about 100°

 

 

 

 

 

 

 

 

 

 

A and B switches after detection.

NOTE

The detection area above is reference. The actual detection range may differ depending on temperature, size of the moving human, color of cloth, moving speed and direction, etc.

• The sensor can detects only a moving human in the detection area.

The sensor detects the motion of a human more sensitive if the human is close to the motion sensor.

Do not touch the light-receiving part of the sensor directly. It may reduce its sensitivity.

Glass between the sensor and human much reduces the sensitivity.

Cord cramp (supplied)

Double-sided adhesive tape

Stick the supplied cord cramp on the back of the main unit and lace the sensor cable through the cramp.

Angle of the sensor

You can adjust the vertical angle of the motion sensor. Change the screw holes on the sides of the sensor to upper ones and adjust the angle.

Change the screw holes to upper ones.

Image 18
Contents GM-F520S GM-F470S GM-F420S Safety Precautions Power ConnectionHow to replace the fuse Screen MaintenanceDear Customer CabinetHow to attach the stand InstallationPrecautions To prevent an accidental fallRemote control Parts IdentificationMonitor Connections Audio 1 OUTAudio 2 OUT Video output terminals Video input terminalsAudio input terminals Audio output terminalsVideo RGB DVI-D Available signalsVideo signals GNDComputer signals RGB DVI-DDaily Operations Activating the Dual Display Selecting the picture modeDisplaying the current status Controlling only the monitor with specified IDMenu Operation Select an item by pressing 5 ∞ , then pressDisplay the menu Menu Configuration-MAIN Menu Multi Size Color SystemMulti Display Dual DisplayMenu Configuration-SET-UP Menu Program SET Sunday Monday Subnet Mask Default Gateway DNS ServerPresent Time Tuesday WednesdaySetting the Security Lock Using the timerInstallation and connection Outline of the motion sensorAngle of the sensor Setting About the external control Remote in SEL CNT. RJ45 OUTUsing the serial communication To assign the functions to the pin terminals How to Use External ControlUsing the MAKE/TRIG. system OperationUsing the LAN system To join the networkOperation on the web browser Motion Sensor Setting General-Purpose ControlFunction Aspect Direct Selection Full Troubleshooting Please Enter Pass ID Symptom Probable cause and corrective actionSetting Following are not malfunctionsSelf-diagnostic Report Sheet Self-diagnostic indicationIf the trouble still persists, follow the procedure below TEMP. OverSpecifications GeneralGM-F520S DimensionsInput/output terminals Motion sensorTop view Front view GM-F470SGM-F420S Rear viewPage Victor Company of Japan, Limited 0209TKH-MW-MT