<LAN Setting>

Setting the log-in name for the control screen and E-mail of the monitor. You can also confirm the network setting.

Troubleshooting

Solutions to common problems related to the monitor are described here. If none of the solutions presented here solves the problem, unplug the monitor and consult an authorized dealer or service center.

 

 

 

Click to finish the operation.

Menu 1

Menu 2

Menu 3

Menu 4

Main Control

Motion Sensor Setting

General-Purpose Control

LAN Setting

 

 

 

Log Out

LAN Setting

 

 

3

Power is not supplied.

]Is the power cord connected (see page 6)?

]Is the main power switch (POWER) turned on (see page 10)?

No picture.

] Is the correct input selected (see page 10)?

] Connect the signal cable firmly.

1

2

 

 

 

MAC Address:

00:04:A3:00:00:05

 

IP Address:

10.52.41.39

 

Subnet Mask:

255.255.255.0

 

Default Gateway:

10.52.41.254

 

DNS Server:

192.168.0.1

 

 

 

 

Enter Log In Name:

ReEnter to Confirm:

OK

Set EMail Address

EMail Address to Send

SMTP Server

Mail Account

Mail Password

OK Get Status All Clear

Error Notification Mail

Send Test-Mail

45

] Check if the input signal format is acceptable

on the monitor.

] Are the devices connected correctly (see page

6)?

] Are signals being input from the connected

devices?

] Is brightness adjusted correctly (see page 13)?

No sound.

]Is the volume set at minimum (see page 10)?

]Is the muting function activated (see page 10)?

]Is “AUDIO ASSIGN” set correctly (see page 13)?

1Displays the current network setting.

2Sets the log-in name to log in the web control screen.

• Up to 8 characters can be used.

Click “OK” to confirm the log-in name setting.

3E-mail settings for the monitor to send the error notification via E-mail.

• For details about the setting, consult the person

in charge of the mail server.

1Enter the mail address for the monitor.

2Enter the E-mail address (up to 3 addresses) to receive the error notification from the monitor.

• Up to 48 characters can be used for each

mail address.

3Enter the SMTP server address (up to 32 characters).

4Enter the E-mail account of the monitor (up to 32 characters).

5Enter the Email password of the monitor (up to 16 characters)

Click “OK” to confirm the mail setting.

Click “Get Status” to load the current settings. Click “All Clear” and then “OK” to delete the mail setting.

4Check here to receive the error notification from the monitor.

The error message is sent to the mail address specified in 3-2.

5Click to send the test mail.

You may not be able to send E-mails depending on the network environment or the verification settings of the server.

3-4and 3-5are necessary when access to the SMTP server requires authentication. Ask the server administrator for details.

“POP before SMTP” is not supported.

Self-diagnostic lamp lights (flashes).

]See page 27 for details.

The remote control does not work.

] Are the batteries installed correctly (see page 5)? ] Are the batteries exhausted?

] Is the front end of the remote control pointing toward the remote sensor?

] Is there any object blocking the path between the remote control and the remote sensor?

] Is the monitor too far away from you?

]Are the functions of motion sensor set to “ON”?

25

Image 25
Contents GM-F520S GM-F470S GM-F420S Power Connection Safety PrecautionsHow to replace the fuse Dear Customer MaintenanceScreen CabinetPrecautions InstallationHow to attach the stand To prevent an accidental fallParts Identification Remote controlMonitor Audio 1 OUT ConnectionsAudio 2 OUT Audio input terminals Video input terminalsVideo output terminals Audio output terminalsVideo signals Available signalsVideo RGB DVI-D GNDRGB DVI-D Computer signalsDaily Operations Displaying the current status Selecting the picture modeActivating the Dual Display Controlling only the monitor with specified IDSelect an item by pressing 5 ∞ , then press Menu OperationDisplay the menu Menu Configuration-MAIN Menu Multi Display Color SystemMulti Size Dual DisplayMenu Configuration-SET-UP Menu Present Time Subnet Mask Default Gateway DNS ServerProgram SET Sunday Monday Tuesday WednesdayUsing the timer Setting the Security LockOutline of the motion sensor Installation and connectionAngle of the sensor Setting Remote in SEL CNT. RJ45 OUT About the external controlUsing the serial communication Using the MAKE/TRIG. system How to Use External ControlTo assign the functions to the pin terminals OperationTo join the network Using the LAN systemOperation on the web browser General-Purpose Control Motion Sensor SettingFunction Aspect Direct Selection Full Troubleshooting Setting Symptom Probable cause and corrective actionPlease Enter Pass ID Following are not malfunctionsIf the trouble still persists, follow the procedure below Self-diagnostic indicationSelf-diagnostic Report Sheet TEMP. OverGeneral SpecificationsInput/output terminals DimensionsGM-F520S Motion sensorGM-F420S GM-F470STop view Front view Rear viewPage 0209TKH-MW-MT Victor Company of Japan, Limited