Honeywell Optiflex Mounting, Wiring, and Setup, Setup Considerations, Voltage Trigger Function

Page 7

S E C T I O N 2

Mounting, Wiring, and Setup

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

In This Section

Setup Considerations

Wiring and Setup of Optiflex

 

Mounting Optiflex

 

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

Setup Considerations

Cameras connected to Optiflex can either be triggered by system events from a Honeywell Vista control panel, from the voltage triggers provided, or both. Optiflex can also be used without any triggers at all, if the system is configured to automatically scan the cameras one at a time, or if the cameras are always on. If using the voltage triggers, refer to the table below to determine which camera each voltage trigger turns on.

Voltage Trigger

Function

 

 

1

Captures Video on Camera 1

 

 

2

Captures Video on Camera 2

 

 

3

Captures Video on Camera 3

 

 

4

Captures Video on Camera 4

 

 

5

Captures Video on Camera 5

 

 

6

Captures Video on Camera 6

 

 

7

NTSC Advance

 

 

8

Captures Video on All Cameras

 

 

If using a Honeywell Vista control panel, the cameras are turned on using Output (relay) Programming commands in the control panel. To accomplish this, enable a 4204 Relay Module in the system’s Device Programming Mode as Device Address 12. Then program eight logical relays and point to the same four physical relays twice, programmed as shown in the table below, using system events or zones/zone lists as desired to turn on the relays as shown below. Cameras are turned on through the ECP (Data In and Data Out) connections (See “Wiring and Setup of Optiflex”) in this section, and the control panel’s Programming Guide for information on how to program output relays.

4204 Output Command (4204 on ECP Address 12)

Function

 

 

Relay 1: Turn ON for 2 seconds

Captures Video on Camera 1

 

 

Relay 2: Turn ON for 2 seconds

Captures Video on Camera 2

 

 

Relay 3: Turn ON for 2 seconds

Captures Video on Camera 3

 

 

Relay 1: Continuous Pulse

Captures Video on Camera 4

 

 

Relay 2: Continuous Pulse

Captures Video on Camera 5

 

 

Relay 3: Continuous Pulse

Captures Video on Camera 6

 

 

Relay 4: Continuous Pulse

NTSC Advance

 

 

Relay 4: Turn ON for 2 seconds

Captures Video on All Cameras

 

 

2-1

Image 7
Contents ADEMCO Optiflex Page Table of Contents Page Introduction to Optiflex Optiflex FeaturesGeneral Features General InformationOptiflex Typical System Block Diagram Voltage Trigger Function Mounting, Wiring, and SetupSetup Considerations Output Command 4204 on ECP Address FunctionMounting Optiflex Mounting OptiflexHeader Connector Wiring and Setup of OptiflexMake Sure ALL System Grounds are Connected Together Tour Ntsc Output ConfigurationNtsc Guard Tour Mode Camera Scanning Mode Camera Dwell Time Dip Sec 16 sec SwitchOptiflex Installation and Setup Guide How to Enable Video on Symphony Setting Up Optiflex Using SymphonyHow to Set Up Video Options on Symphony Camera Status LEDs Operational Status IndicatorsNetwork Status LEDs Camera Activity Optiflex Status LEDsSpecifications SpecificationsOptiflex Installation and Setup Guide Ntsc Guard Tour Mode Camera Selection Trigger Data DIP Switch SettingsNtsc Output Configuration DIP Switch 1 Ntsc Guard Tour Mode Camera Dwell TimeOptiflex Installation and Setup Guide Page Page Limited Warranty ÊK0948V2pŠ