Honeywell Optiflex setup guide Ntsc Output Configuration, Tour, Dip Sec 16 sec Switch

Page 11

Section 2: Mounting and Wiring

NTSC Output Configuration

Selects either one camera or guard tour (camera scanning) for default local viewing through a monitor.

Dip

Cam-1

Cam-2

Cam-3

Cam-4

Cam-5

Cam-6

Guard

Reserved

Switch

View

View

View

View

View

View

Tour

 

 

 

 

 

 

 

 

 

 

1

OFF

ON

OFF

ON

OFF

ON

ON

OFF

 

 

 

 

 

 

 

 

 

2

OFF

OFF

ON

ON

OFF

OFF

ON

ON

 

 

 

 

 

 

 

 

 

3

OFF

OFF

OFF

OFF

ON

ON

ON

ON

 

 

 

 

 

 

 

 

 

NTSC Guard Tour Mode (Camera Scanning Mode) – Camera Dwell Time

Selects the amount of time to remain on each camera before scanning to the next.

Dip

2 sec

 

4 sec

8 sec

 

16 sec

Switch

 

 

 

 

 

 

 

 

 

 

 

 

 

4

OFF

 

ON

OFF

 

ON

 

 

 

 

 

 

 

5

OFF

 

OFF

ON

 

ON

 

 

 

 

 

NTSC Guard Tour Mode – Camera Selection

 

 

 

Dip

Use All Six Cameras

Use First Four

Switch

for Guard Tour

Cameras for Guard

 

 

 

 

 

Tour

 

 

 

 

 

6

 

OFF

 

ON

 

 

 

 

 

 

 

8.Turn on the power source. Wait approximately 30 seconds while the Optiflex software loads and the video sources are detected. During this time Optiflex scans for cameras, and if they are detected begins monitoring them. If they are not detected, they will not be monitored.

During the boot-up process the cover should be removed to enable the installer to view status LEDs.

If a new camera is added after the initial boot–up process, power must be turned off and reapplied for the new camera to be detected.

9.After the unit is powered up, check the following: Power LED is ON.

Camera LED is ON for each connected camera.

If connected to the Ethernet hub/router Network LINK LED is ON. Network SELECT, TX and RX LEDs may be flashing.

2-5

Image 11
Contents ADEMCO Optiflex Page Table of Contents Page Introduction to Optiflex Optiflex FeaturesGeneral Features General InformationOptiflex Typical System Block Diagram Voltage Trigger Function Mounting, Wiring, and SetupSetup Considerations Output Command 4204 on ECP Address FunctionMounting Optiflex Mounting OptiflexHeader Connector Wiring and Setup of OptiflexMake Sure ALL System Grounds are Connected Together Tour Ntsc Output ConfigurationNtsc Guard Tour Mode Camera Scanning Mode Camera Dwell Time Dip Sec 16 sec SwitchOptiflex Installation and Setup Guide How to Enable Video on Symphony Setting Up Optiflex Using SymphonyHow to Set Up Video Options on Symphony Network Status LEDs Operational Status IndicatorsCamera Status LEDs Camera Activity Optiflex Status LEDsSpecifications SpecificationsOptiflex Installation and Setup Guide Ntsc Guard Tour Mode Camera Selection Trigger Data DIP Switch SettingsNtsc Output Configuration DIP Switch 1 Ntsc Guard Tour Mode Camera Dwell TimeOptiflex Installation and Setup Guide Page Page Limited Warranty ÊK0948V2pŠ