Honeywell setup guide Wiring and Setup of Optiflex, Header Connector

Page 9

Section 2: Mounting and Wiring

Wiring and Setup of Optiflex

Before wiring Optiflex, make sure power is turned off and review the important notes below.

1.Use a Listed Class 2 power supply suited for the application (see Section 5: Specifications).

2.Panel triggered UL Installations: Optiflex may be connected as a supplemental device to listed fire and/or burglar alarm control panels that support the 4204 relay module except as noted below.

UL

In UL installations, Optiflex may be connected to panels that have ground fault

detection only if the local authority having jurisdiction allows the ground fault

detection feature to be disabled.

In non-UL installations requiring ground fault detection, when possible, use cameras powered by a power source such as a plug-in transformer that is not earth grounded and isolate the camera's mounting brackets from earth ground. Connect a video ground loop isolation device such as Vicon's V235GLTA Ground Loop Transformer to the coaxial cable that runs between Optiflex and the video monitor or recorder (or camera if required) causing the ground fault. Video ground loop isolation devices are not UL listed and may not be used in UL installations.

Optiflex is supplied with a header connector. Insert wires into the connector and secure by placing the header arms in the down position (see Figure 3). When all wires are secured, mount the header on Optiflex by snapping into place.

AUI-016-V0

Figure 3. Header Connector

2-3

Image 9
Contents ADEMCO Optiflex Page Table of Contents Page General Features Optiflex FeaturesGeneral Information Introduction to OptiflexOptiflex Typical System Block Diagram Setup Considerations Mounting, Wiring, and SetupOutput Command 4204 on ECP Address Function Voltage Trigger FunctionMounting Optiflex Mounting OptiflexHeader Connector Wiring and Setup of OptiflexMake Sure ALL System Grounds are Connected Together Ntsc Guard Tour Mode Camera Scanning Mode Camera Dwell Time Ntsc Output ConfigurationDip Sec 16 sec Switch TourOptiflex Installation and Setup Guide How to Enable Video on Symphony Setting Up Optiflex Using SymphonyHow to Set Up Video Options on Symphony Operational Status Indicators Camera Status LEDsNetwork Status LEDs Camera Activity Optiflex Status LEDsSpecifications SpecificationsOptiflex Installation and Setup Guide Ntsc Output Configuration DIP Switch 1 Trigger Data DIP Switch SettingsNtsc Guard Tour Mode Camera Dwell Time Ntsc Guard Tour Mode Camera SelectionOptiflex Installation and Setup Guide Page Page Limited Warranty ÊK0948V2pŠ