Vidikron vision70 manual Gray Yellow Cyan Green Magenta Red Blue

Page 60

Operation

Contrast: On your external test pattern source, select a stepped, gray-bar pattern like the one shown in Figure 4-3.

Figure 4-3. Typical Gray Bar Pattern for Adjusting Contrast

Select Contrast from the Picture Adjust menu and press ENTER. Adjust the contrast to a point just below which the white rectangle starts to increase in size.

Brightness and contrast controls are interactive. A change to one may

Note require a subtle change to the other in order to achieve the optimum setting.

Color Saturation: On your external test pattern source, select a color bar pattern like the one shown in Figure 4-4.

gray

yellow

cyan

green

magenta

red

blue

Figure 4-4. Typical Color Bar Pattern for Adjusting Color Saturation and Tint

48

Vidikron Vision 70 Series Owner’s Operating Manual

Image 60 Contents
Series 1080p DLP Projectors Page TWO Year Limited Warranty For Projectors, Video Processors and ControllersEffective Warranty Date Vidikron Safety Precautions 1Table of Contents Table of Contents OperationMaintenance and Troubleshooting Table of Contents 1List of Figures List of Figures Xii 1Introduction About This ManualUsing This Manual They also provide supplemental informationPerformance or cause a malfunction If you need Turn toDescription, Features and Benefits Optional Accessories POWER/STANDBY LED Indicates power status as follows Vision 70 at a GlanceTemp LED Vision 70 Connector Panel Cable Access Door Open to access connectorsBuilt-In Keypad Vision 70 Remote Control Vision 70 Remote ControlOn / OFF Source Selection Buttons Comp 1 SD ComponentVID S-Video Comp 2 HD ComponentMemory Preset Buttons Cursor KeysPicture-In-Picture PIP / Picture-By-Picture PBP Controls VAC V2 Aperture ControlRemote Control/Built-In Keypad Functional Comparison Motorized Lens Controls3Installation Remote ControlOperation Quick Setup Installation OverviewStep Procedure For Details, Refer to If installing a Vision 70/CineWide or Vision 70/CineWideInstallation Considerations Projector Installation OptionsInstallation Type Advantages ConsiderationsThrow Ratios for the Vision 70 Series Throw Range Throw RatioProjector Model VisionCeiling Installation Floor InstallationVertical and Horizontal PositionFolded Optics Installing the Optional CineWide Lens Mount With AutoScope Vision 70 with Ceiling Mount Adapters/Projector Stands AutoScope Lens Motor Installation Installing the Fixed CineWide Base Plate Vision 70/CineWide Vision 70/CineWide with Lens Base PlateAdjusting the Projector Mounting the VisionFloor Mounting Upright Ceiling Mounting InvertedConnector Panel Access Connecting SourceConnections to the Vision 10. RGB Connections 11. Progressive Component Video Connections DTV or Progressive Component YPbPr SourceDTV Source DVD Player, VCR Satellite Receiver Etc 12. Composite, S-Video and Component Video ConnectionsConnection 13. RS-232 Control System ConnectionEquipment AutoScope Lens Motor RearTurning on the Power Connecting to AC PowerPower source Focus Zoom Vertical Lens Shift Installing and Adjusting the CineWide Anamorphic Lens Anamorphic Lens Installation Adjustment Vision 70/CineWidePrimary lens is perfectly centered on the screen Adjusting the Lens Height Y Anamorphic Lens Top View Adjustment Vision 70/CineWide withAutoScope Attach Lens Mounting Assembly to Lens Motor Carriage Plate 18. Attaching the Anamorphic Lens to the Lens Adapter RingAdjusting the Horizontal X Lens Position Installation Anamorphic Lens Top View Adjusting the Geometry Installation Using Picture-In-Picture/ Picture-By-Picture PIP/PBP 4OperationSelecting Video Memory Selecting an Aspect Ratio Selecting An Input Source Using the On-Screen Menus Adjust InstallationService PicturePicture Adjust Main MenuPerform the adjustments in the order listed here Typical Pluge Pattern for Adjusting BrightnessGray Yellow Cyan Green Magenta Red Blue Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Image Option Image OptionAspect Ratio Settings DescriptionRemote Projector Status Installation Exit to return to the previous menu or Menu to exitService ServiceOperation Operation Remote Control ISF Calibration ISF CalibrationOperation Operation 5Maintenance and Troubleshooting Lamp ReplacementLamp assembly for replacement Troubleshooting Tips Troubleshooting ChartSymptom Possible Causes Solution Correct Vision 70 input Maintenance and Troubleshooting Serial Command Syntax RS-232 Connection and Port ConfigurationSerial Commands 6Serial CommunicationsSerial Communications Serial Commands Serial Commands 7Specifications Vision 70 SpecificationsHome Theater Calibration Specifications Industry-Standard SpecificationsPower Requirements DimensionsLimited Warranty Specifications are subject to change without noticeRegulatory Approvals Vision 70 Dimensions Vision 70 Dimensions with Optional Fixed Anamorphic LensVidikron Vision 70 Series Owner’s Operating Manual Power-cycle the projector to see the change Page Vidikron