5. Maintenance and Troubleshooting
The lamp should be replaced when it reaches the end of its life (typically 2000 hours), or sooner if a noticeable degradation in brightness occurs. Contact your Runco dealer to obtain a replacement lamp.
5.1
Lamp Replacement
1.Turn off the projector and unplug the power cord. Allow the projector to cool down for approximately 45 minutes prior to removing the lamp assembly for replacement.
2.Loosen the four rear Lamp Cover screws and remove the cover.
REMOVE THESE SCREWS |
3.Remove the two lamp assembly mounting screws.
4.Grasp the lamp assembly handle and pull gently, removing the lamp module from the projector housing.
5.Install the new lamp module.
6.Replace the lamp cover and
7.Reset the Lamp Hour counter. To do this, select Service from the Main Menu, then Display Device, then Installation. Use the cursor buttons to highlight Reset under “Lamp Hours” and press ENTER.
If you need to remove the lens – either to replace it or to prepare the projector for shipment – proceed as follows:
Only trained, authorized Runco dealers should attempt to
Note remove or replace a lens. Please read this procedure carefully before doing so.
Lens replacement is normally performed at the Runco factory. Field replacement of lenses is generally only required if the projector is
1.Power down the projector and wait five minutes to allow the lamp to cool.
2.Remove the secondary anamorphic lens, if present.
5.2
Lens Replacement
Runco | 45 |