Figure A-3. VX-2ix Secondary RS-232 Port
4.Connect the color sensor to any available COM or USB port.
5.Launch HyperTerminal. Open a connection using these parameters: 19200 baud, 8 data bits, no parity,1 stop bit and no flow control.
6.Press <Enter>. The
7.Start your color analyzer. Position the sensor approximately 6 to 12 inches from the screen, facing it at a slight angle (upward or to one side) so that the color of the screen is included in the calibration.
Table
When you enter a valid command, the
Table A-1. Serial Commands for Gamut Adjustment
Command | Parameter | Value | Description | |
(min/max) | Stored? | |||
|
| |||
|
|
|
| |
GAMUT WHITE | NA | NA | Displays white field on screen for | |
|
|
| measuring x and y coordinates; | |
|
|
| shows current x and y | |
|
|
| coordinates for white on the | |
|
|
| command line. | |
|
|
|
| |
GAMUT RED | NA | NA | Displays red field on screen for | |
|
|
| measuring x and y coordinates; | |
|
|
| shows current x and y | |
|
|
| coordinates for red on the | |
|
|
| command line. | |
|
|
|
|
A.3
Serial Command
Syntax
Runco |