Operation

ISF Calibration Use the ISF Calibration menu to perform advanced picture quality adjustments. This

menu should be used by ISF-certified technicians only.

ISF Calibration

Picture Adjust

White Balance

Blue Enable

Factory Reset

Splash Duration

You must enter a passcode to access the ISF Calibration menu.

Note

Picture Adjust: The controls in this menu are identical to those in the main Picture Adjust menu, but are accessible only by entering the ISF Calibration menu passcode. This makes it possible to restore the picture quality settings to what they were when the Crystal Series LCD was installed, simply by recalling the “ISF Night” or “ISF Day” preset.

Brightness: Refer to Brightness on page 29.

Contrast: Refer to Contrast on page 30.

Color: Refer to Color Saturation on page 31.

Tint: Refer to Tint on page 31.

Sharpness: Refer to Sharpness on page 32.

ADC Phase Adj.: This control works similarly to the Phase adjustment for RGB signals (refer to Phase on page 35). Use it to improve the apparent sharpness of 720p and lower-resolution Component, S-Video or Composite sources. For best results, adjust ADC Phase while displaying a “Sharpness” pattern (Figure 4-5).

DNR: Refer to DNR on page 32.

MPEG NR: Refer to MPEG NR on page 32.

Backlight: Refer to Backlight on page 32.

Color Temp.: To choose a color temperature setting, select Color Temp. from the Picture Adjust menu and press ENTER. (Color temperature defines the “color of gray.”) The choices are 5400K, 6500K, 8500K and Custom. The default setting, 6500K, is appropriate for most situations. Higher settings produce a “bluer” picture; lower ones impart a reddish hue to the image.

Each color temperature setting has six (6) “white balance” parameters associated with it (two each for red, green and blue). (The White Balance settings for the 5400K, 6500K and 8500K color temperatures are factory-set and cannot be changed.)

To create a “Custom” color temperature, select Custom from the Tip Color Temp. menu and press ENTER. Then, press ENTER a

second time to go directly to the White Balance menu. (This shortcut is available only from the ISF Calibration menu.)

Gamma: Refer to Gamma on page 33.

Save Settings: For each input and supported resolution, the Crystal Series LCD lets you save image quality settings as presets that you can recall at a later time. You can create up to three presets – designated “Custom,” “ISF Day” and “ISF Night” – per input and resolution.

You should save changes to any of the following settings to a preset; otherwise they will be lost when a new input source or resolution is selected:

Brightness

Contrast

Color saturation

38 CX-47HD/CX-OPAL47/CX-65HD Installation/Operation Manual

Image 52
Contents CX-47HD CX-OPAL47 CX-65HD Page RuncoCare Standard Two Year Limited Warranty RuncoCare Standard FeaturesRuncoCare Claim Procedure Page Copyright and Trademarks Important Safety Instructions Compliance Information Declaration of ConformityFCC Part Page Table of Contents ISF Calibration List of Figures List of Figures Introduction About This ManualUsing This Manual TipDescription, Features and Benefits Key Features and Benefits Parts ListIntroduction Controls and Functions Controls and IndicatorsCrystal Series LCD at a Glance Handles Crystal Series LCD Inputs and Outputs Model CX-47HD and CX-OPAL47 Inputs and OutputsModel CX-65HD Inputs and Outputs Speaker Output Left + Right Crystal Series LCD Remote Control VOL+RGB HD PIP Remote Control InstallationBattery Installation Quick Setup Installation OverviewInstallation Considerations Connections to the Crystal Series LCDWall-Mounting the Crystal Series LCD Ambient LightConnecting the Crystal Series LCD to Source Sections that follow ComponentsAnalog RGB Connections VCR Connecting External Speakers OptionalDigital Audio Connection Connecting an External IR ReceiverRS-232 Controller ConnectionInstallation Operation Turning on the PowerChanging the OSD Language Setting the PC Display Properties Using the On-Screen Menus Crystal Series LCD OSD Menu Structure Source Main MenuAspect Ratio Aspect Ratio Settings Picture Adjust Typical Pluge Pattern for Adjusting Brightness Gray Yellow Cyan Green Magenta Red Blue Typical Test Pattern for Adjusting Sharpness Operation Balance Equalizer Speaker Characteristics of the incoming signal SetupLetterbox Mode = Letterbox Hdmi 1 Hdmi 2 Hdmi 3 Hdmi 4 Scart Component RGB Video Menu should be used by ISF-certified technicians only Gain Crystal Series LCD Splash Screen Using Picture-In-Picture PIP Changing the PIP PositionChanging the PIP Size Swapping the Main and PIP ImagesOperation Maintenance and Troubleshooting CleaningTroubleshooting Tips Cleaning the Display Panel Body and Remote ControlMaintenance and Troubleshooting Serial Commands Serial CommunicationsS4E SDE 0001 Personalizing the Splash Screen Using Serial Commands 0090Serial Communications Specifications Crystal Series LCD SpecificationsWeight including stand Regulatory Approvals Limited Warranty Crystal Series LCD Dimensions CX-47HD/CX-OPAL47 Dimensions Top/FrontCX-47HD/CX-OPAL47 Dimensions Rear/Side CX-65HD Overall Dimensions Top/Front CX-65HD Overall Dimensions Rear/Side Supported Signal Timings by Input Supported TimingsPAL Page 020-0969-00 Rev. B January