ALARM RECORDING
By connecting the ALARM IN terminal to a door switch, an interphone, etc., a recording can be done only when necessary.
Alarm Recording Setting
Alarm recording is performed when there is an input (trigger) at the ALARM IN terminal, “A” is displayed on the digital display.
œMake all necessary connections.
œFollow the Before starting steps, under “NORMAL RECORDING”.
œThe alarm triggers are received while in recording and stop modes.
1Press the MENU button to display the (MAIN MENU 1) menu.
2Press the SHIFT ] button to select the “6. RECORD SET” line, then press the MENU button.
øThe (RECORD SET) menu appears.
@@@@@<RECORD@SET>
*ALARM@RECORD@MODE@@Y1
@@SPEED@@@@@@@@@@@@@N12
@@DURATION@@@@@@@@@@20S
*PRE@ALARM@RECORD@@@OFF
*POST@ALARM@RECORD@@OFF
@@DURATION@@@@@@@@@@20S
*TRIGGER@SHOT@REC@@@1
*TAPE@END@MODE@@@@@@REW
3Press the DATA l (or j) button to set the desired alarm recording mode, then press the SHIFT ] button.
Y1. . . . . . Alarm recording is done when there is an alarm trigger.
Y2. . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording.
Y3. . . . . . Alarm recording is done only if there is an alarm trigger and the VCR is not in programmed timer recording mode.
Y4. . . . . . Alarm recording is done only when there is an alarm trigger during programmed timer recording duration. Timer recording is not possible.
N. . . . . . Alarm recording is not performed even if there is an alarm trigger.
4Press the DATA l (or j) button to select the desired recording speed, then press the SHIFT ] button.
N12. . . . .
U12. . . . .
H12. . . . .
F12 . . . . .
H24. . . . .
F24 . . . . .
NC . . . . . Recording at the speed already set
5Press the DATA l (or j) button to select the desired alarm recording duration (20S, 40S, 1M, 2M, 3M, 4M, 5M or CC).
CC. . . . . Recording as long as the alarm signal is being input (minimum 5 seconds)
6Press the MENU EXIT button to save the settings.
NOTES:
œDuring alarm recording all buttons are disabled.
œIf “OFF” is displayed on the digital display, alarm recording is not possible in order to prevent the recorded tape to be recorded over.
œIf an alarm trigger is received while alarm recording is in progress, recording duration for the second alarm will be calculated from that point. The alarm counter will register the alarm, but it will not be found during an alarm scan and alarm search.
œIf there is a power failure during alarm recording, and the power is restored within the recording set duration, alarm recording will continue.
œIf the alarm recording duration is short, the alarms may not be found during an alarm scan or an alarm search. If the alarms are going to be reviewed using alarm scan or alarm search, then in
œTo do alarm recording during series recording, set “ALARM RECORD MODE” to “Y1” or “Y3”. Alarm recording will be conducted only if the VCR is recording.
English | 27 |