Sanyo DTL-4800 instruction manual Back Panel, Male on the VCR

Page 8

LOCATIONS OF CONTROLS AND INDICATORS

Back Panel

1

2 3 45

6 7 89

F G

IN

OUT

IN OUT

IN OUT

VIDEO

S-VIDEO

AUDIO

 

 

A RS485 B

 

 

ADDRESS

485 TERMINATE

 

 

ON

ON

 

 

 

PUSH

 

 

OFF

232 OFF OPEN

AC IN

 

 

REMOTE

 

 

 

 

 

RS232C

L

 

K

J I H

Pin locations

Pin locations

 

(female) on the VCR

(male) on the VCR

 

 

1

5

 

MIC IN

EXT

TIMER WARNING TAPE

SW

COM NON REC V.LOSS

TIMER IN OUT

OUT

END OUT OUT

 

OUT

OUT

IN

OUT

COM

IN

OUT

COM

IN

OUT

CLOCK SET

 

SERIES

 

EJECT

ALARM

 

TRIGGER

IN

OUT

 

 

RESET

 

SHOT REC

ALARM

 

 

IN

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

1

6

6

9

 

 

 

 

NOTE:

Do not connect to phone line.

1 Ventilation opening

NOTE: The cooling fan is located behind this opening, make sure it is not blocked.

2 VIDEO IN (video input) jack

3 VIDEO OUT (video output) jack

4 S-VIDEO IN (S-VHS video input) jack

5 S-VIDEO OUT (S-VHS video output) jack 6 RS485 A connector (RJ11 type)

7 RS485 B connector (RJ11 type)

8 AUDIO IN (audio input) jack

9 AUDIO OUT (audio output) jack F MIC IN (microphone input) jack G Various terminals (see page 8)

H I J K

L

Lithium Battery compartment

REMOTE (remote control input) jack

RS232C connector (D-sub 9-pin type)

DIP switches

œUsed when controlling the VCR through the RS485 or the RS232C connectors.

AC power input

English

7

Image 8
Contents Digital Declaration of Conformity PrecautionsFor the customers in Canada Precautions Accessories ContentsFeatures Locations of Controls and Indicators Front PanelSTILL/PAUSE button Search FRAME/FIELD button Eject button Menu Exit buttonLocations of Controls and Indicators Operation IndicatorsOperation Mode Indicator Digital DisplayOFF indicator Back Panel Male on the VCRO P Q R S T Connections Installing the Ni-Cd BatteryProtection against power failure Connections Power Cord InstallationAbout the memory reset Sub-menus ON-SCREEN MenusMain menus ON-SCREEN Menus Setting the Language and Clock Language SettingClock Setting Day of week is set automaticallySetting the Language and Clock Automatic Daylight Saving Time AdjustmentChanging the Date/Time Display Position Changing the ON-SCREEN DisplaySelecting the On-screen Display Video Cassette Tapes Setting the Action to Take When a Cassette is Loaded Video Cassette TapesCorrect tape thread check function Various SET 1 menu appearsTape Management Function OperationIf no tape management data is present on the tape If tape management data is present on the tapeTape Management menu appears Setting the Tape Management FunctionTape Management Function Tape Management Conflict Display Conflict display sampleRecording speed mode is displayed on the digital display Pause/Still indicator N blinksNormal Recording Normal Recording Before startingRecording Speed Mode Normal RecordingField HourClog Detection Concerning the Number of Times Tapes can be Rerecorded onRecording Check Record SET menu appears Setting the Mode at the End of the TapeAction to Take when the Video Signal Deteriorates Changes to the Recording Speed Mode During Recording Setup for use with a multiplexerAutorepeat Recording Repeat indicator will lightAutorepeat Recording Alarm Recording Alarm Recording SettingAlarm Recording Alarm Recording Counter DisplayConnections to the Alarm IN/OUT Terminals Alarm Reset in terminalAlarm Search Alarm ScanRecording speed mode Recording duration Seconds Pre Alarm Recording SettingPost Alarm Recording Setting Program Timer Recording Program Timer Recording Press the Data l or j button to select YSetting the Holidays Changing a Program Timer RecordingTo Cancel a Program Timer Recording To Cancel all Program Timer RecordingsThese portions will not be recorded Recording Using AN External Timer Input Trigger Shot Recording Connections Using a MultiplexerTrigger Shot Recording Setup Series Recording Setup Recording will start in series recording modeSeries Recording Series recording connectionsLoop recording connection example with 2 VCRs Continous Loop Recording SetupSeries Recording Playback Tape Counter PlaybackSearch Forward and Reverse Field Advance Forward and ReverseD Search 01 000000 will be displayed on screen DAY/TIME SearchDay/Time Search Setting the Security Lock Setting the Security LockCancel the Security Lock Setting and Canceling the Quick Method Security LockBuzzer SET menu appears Setting the BuzzerIf using the SET UP setting, continue with steps 4 Clock Adjustment Setting procedure on the first VCR is now completedSetting the Cassette Eject Mode Cassette Eject SetupEject terminal connection Eject in terminalSetup for RS-232C or RS-485 USE DIP Switches SetupSW No ExampleSetup for RS-232C or RS-485 USE Setup for RS-232C or RS-485 UseRS-485 RJ-11 connector layout RS-485 ConnectionPOWER/DEW/USED Time menu appears RS-232C 9-pin connector layoutPin Signal Operation Signal direction Timer OUT Terminal Output TerminalsTape END OUT Terminal COM TerminalRemote control setting Output TerminalsRemote Jack NON REC OUT terminalMaintenance Maintaining and Checking The Mechanism MaintenanceMaintenance Table System Down Troubleshooting GuideAfter a Power Failure Specifications Sanyo Industrial VCR Warranty Weekdays 830 AM 500 PM Pacific TimeRD2QD/NA