Sanyo DSR-3009 manual Network Control, Switching to Control by Computer

Page 5

Network Control

Switching to Control by Computer

1 Start your Web browser.

Compatible browsers are Internet Explorer Ver. 5.0 or later. Compatible operating systems are Windows 98, 98ME, 98SE, 2000 and XP.

If a Java Script run-time error appears while using

Internet Explorer, change the settings for Internet

Explorer as shown below.

1. Select Internet Options from the Tools menu, and click the Advanced tab.

2. Make sure that the following check boxes are set as indicated.

2 Enter the URL.

Enter the URL for this unit in the address bar of the browser, and

 

then press the [Enter] key. Enter the IP address specified in the

 

network setting for this unit. (The URL contains the IP address

4

that has been set for this unit in the network settings.)

Enter the default value 192.168.0.1. (Example: “http://192.168.0.1/”)

If the port is set to a value other than the default value of “ 80” , add a “ :” followed by the port number to the end of the IP address.

Example if the port is set to “ 81”

http://192.168.0.1:81/

If you do not have a web browser installed on your computer’s hard disk, you will need to install one.

3 Enter a password (security check).

Enter your user name and password for security checking in the Network password entry box, and then click [OK].

If you enter an incorrect password, the password entry screen will reappear asking you to re-enter the password.

(3)Up to a total of four computers can be connected simultaneously to a single digital video recorder. (However, only one computer can be connected at a user level of ID2 or ID3.)

If the highest-level user connects from a different computer while four computers are already connected, the last one of the lowest-level computers to connect is forcibly disconnected and the highest-level user has priority.

(4)If you make more than one error entering the password or if you click the [Cancel] button in the password entry screen, an “ AUTHENTICATION ERROR” window will be displayed.

(5)If you click a button on the control panel that you are not authorized to use during computer control, the password entry screen will be displayed and you will be prompted for a security check for the required user level for that function.

Select the display language.

When the security check for the password has been cleared, the language selection screen will appear. Select a language and then click [OK]. The operating screen will be displayed in the selected language and computer control will be enabled.

(1)You should use separate passwords for different user levels In accordance with the installation environment. (See p. 20)

(2)If you choose to save the user name and password that you enter, the security check will be cleared automatically the next time you log on. However, passwords that were entered at some time other than the time when you first connected may not be stored in some cases.

(1)Select the display language each time you switch to computer control.

(2)To change the display language, cancel the connection temporarily and then reconnect.

IMPORTANT

You cannot connect to the network while a menu screen is being displayed or when operations associated with playback are being carried out. Clear the menu display or stop the playback operation before reconnecting to the network.

In some cases, you may encounter problems when connecting to the network via a proxy server. If this happens, the proxy setting should be canceled.

Switching to Control by Main Unit

When you click the Sbutton on the computer operating screen, the connection will be canceled and control will switch to the main unit.

• To forcibly cancel the connection from the main unit, press the [EXIT/OSD] button for two seconds or more. No connections will be received by the computer for 10 seconds after the connection has been forcibly canceled.

If communication with the computer is suspended for one minute or more, the connection will be automatically cancelled and control will switch to the main unit.

4

English

Image 5 Contents
DSR-3016 DSR-3009 Contents Viewing Images Symbols used in this manualNetwork Control Functions Basic Specifications for Network ControlNetwork Settings Network Control Switching to Control by ComputerComputer display When disconnected from the network When the connection is forcibly canceled from the main unitWhen control is switched to the main unit Network Control Displays That Appear While ConnectedOperating Panel and Operation Permissions Menu Selection Method SettingsMenu Configuration Clock SET Menu Setting ProceduresDaylight SAVING/EXT. Clock SET Daylight SavingProgram REC SET Menu Setting ProceduresRecording Area SET Recording area resetTotal capacity display Capacity display for each recording areaRemaining Disk Warning Click Save to complete the sub-menu settings or changesRecording Conditions SET Normal REC Mode SET Menu Setting Procedures Week Timer SETStart StopHoliday SET Alarm REC Mode SETClick Save to complete the holiday settings or changes Select the recording cycle from the REC Rate menu Alarm RecordingSet the duration for alarm recording from the Duration menu Alarm or Sensor PRE-ALARM RecordingAlarm and Sensor Display SET Alarm Duration SETAlarm Type Default setting on Type of alarm recording Buzzer SET Network SET Click Save to complete the Playback Drive menu settings Power FAILURE/USED TimeHDD SET Playback DriveEnglish Playing Back Recorded Images Viewing ImagesViewing Live Images Viewing Images Playback Mode OperationsSpecifying the Number of Display Screens On-screen Display Items Image AdjustmentSearch Menus Search for images by using the search mode screenBasic Search Operations Alarm Thumbnail Search Search Mode OperationsAlarm Search TIME/DATE Search Search Mode OperationsArchive Area Search Select TIME/DATE Search from the Search menuSpecify the motion sensor search conditions Motion Detection SearchEnter the number of images in the HOW Many Box Saving Recorded ImagesClick the Start button Playback AreaClick OK in the dialog box and then save Saving Recorded ImagesImage Viewer Screen Page