Sanyo DSR-3009 manual English

Page 23
Pre-alarm recording
When pre-alarm recording has been set beforehand, the same images will be recorded normally in the normal recording area and also in the alarm recording area. The normal recording images will be recorded in this way for the length of time specified by the DURATION setting, so that the images recorded before the alarm occurred can also be seen when the alarm recording is played back.
1 Set the pre-alarm recording conditions using the [PRE-ALARM RECORDING] menu in the ALARM REC MODE SET menu screen. (See p. 17)
2 The most recent images will be recorded automatically for the specified duration, and they will be updated by being overwritten.
3 When an alarm recording is being carried out, pre-alarm recording is automatically suspended, and it is resumed when the alarm recording is finished.
22
Alarm recording stops automatically after the amount of time specified by the DURATION setting has elapsed.
3
Alarm images are recorded automatically in the alarm recording area when the alarm input terminals or motion sensor have detected an alarm.
When alarm recording is in operation, normal recording, timer recording and pre-alarm recording are automatically
suspended, and they are resumed when the alarm recording is finished.
1 The conditions for alarm recording are set beforehand using ALARM REC MODE SET menu screen. (See p. 15)
2 Alarm recording begins automatically when an alarm is detected, regardless of the operating or working conditions of the digital video recorder.
Alarm recording
This is for automatically recording an image that is being viewed into the normal recording area at a specified time. Timer recording is not possible during normal recording.
1 The conditions for timer recording (day of the week, time, recording speed, etc.) are set beforehand using the TIMER SET menu screen. (See p. 14)
2 Timer recording is started by clicking the Qbutton on the operating panel and recording will start and stop automatically in accordance with the specified times. The timer recording operation is indicated by a “ TIMER STANDBY” or “ TIMER RECORDING” message appearing on the screen.
If “ OLY AL-RC ON TMR” has been selected as the ALARM RECORDING setting (see p. 16), timer recording standby operation using the Qbutton is not possible.
3 To cancel timer recording, click the Qbutton on the operating panel again when in timer recording standby mode.
Timer recording
This is a manual operation for recording live images that are currently being viewed into the normal recording area.
1 Click the Obutton on the operating panel to start normal recording.
2 Click the Pbutton on the operating panel to stop normal recording.
If more than one camera is connected to the digital video recorder for monitoring, the images for all cameras that have been set in the REC CAMERA GROUP specified by the NORMAL REC MODE SET setting will be recorded, regardless of the number of live image display screens. (See p. 13)
Normal recording
Recording Images
This digital video recorder can record images being monitored and alarm on the internal hard disk by the methods specified below.
In order to record images, the necessary menu settings should be made beforehand in accordance with the installation environment. (See p. 7)

English

Image 23 Contents
DSR-3016 DSR-3009 Contents Viewing Images Symbols used in this manualNetwork Control Functions Basic Specifications for Network ControlNetwork Settings Network Control Switching to Control by ComputerNetwork Control Displays That Appear While Connected When the connection is forcibly canceled from the main unitComputer display When disconnected from the network When control is switched to the main unitOperating Panel and Operation Permissions Menu Selection Method SettingsMenu Configuration Daylight Saving Menu Setting ProceduresClock SET Daylight SAVING/EXT. Clock SETProgram REC SET Menu Setting ProceduresCapacity display for each recording area Recording area resetRecording Area SET Total capacity displayRemaining Disk Warning Click Save to complete the sub-menu settings or changesRecording Conditions SET Normal REC Mode SET Menu Setting Procedures Stop Timer SETWeek StartHoliday SET Alarm REC Mode SETClick Save to complete the holiday settings or changes Select the recording cycle from the REC Rate menu Alarm RecordingSet the duration for alarm recording from the Duration menu Alarm or Sensor PRE-ALARM RecordingAlarm and Sensor Display SET Alarm Duration SETAlarm Type Default setting on Type of alarm recording Buzzer SET Network SET Playback Drive Power FAILURE/USED TimeClick Save to complete the Playback Drive menu settings HDD SETEnglish Playing Back Recorded Images Viewing ImagesViewing Live Images Viewing Images Playback Mode OperationsSpecifying the Number of Display Screens On-screen Display Items Image AdjustmentSearch Menus Search for images by using the search mode screenBasic Search Operations Alarm Thumbnail Search Search Mode OperationsAlarm Search Select TIME/DATE Search from the Search menu Search Mode OperationsTIME/DATE Search Archive Area SearchSpecify the motion sensor search conditions Motion Detection SearchPlayback Area Saving Recorded ImagesEnter the number of images in the HOW Many Box Click the Start buttonClick OK in the dialog box and then save Saving Recorded ImagesImage Viewer Screen Page