CHAPTER 5: LED Indicator

5. LED Indicator

The front of A/S-4 enclosure provides 10 light emitting diodes (LED) indicators. The indicators are arranged and labeled in the following order, from left to right.

 

TTX

Terminal Transmit Data

 

TRX

Terminal Receive Data

 

TCD

Terminal Carrier Detect

 

TCTS

Terminal Clear To Send

 

ERROR

Error Condition

 

POWER

Power On

 

MCTS

Modem Clear to Send

 

MCD

Modem Carrier Detect

 

MRX

Modem Receive Data

 

MTX

Modem Transmit Data

TTX

Flashes as data is transmitted by the A/S-4 out the terminal port.

TRX

Flashes as data is received by the A/S-4 from the terminal port.

TCD

Lights when the A/S-4’s input of Carrier Detect is high on the terminal port. This light

 

must be on while TRX is flashing for A/S-4 to process received data.

TCTS

Lights when the A/S-4’s input of Clear to Send is high on the terminal port. This light

 

must be on for the A/S-4 to transmit data on the terminal port.

ERROR

Error Condition Exists - Memory error, bad received block check, or buffer overflow.

POWER

Lights when the A/S-4 is plugged in and the +5 Volt power supply is ok.

MCTS

Lights when the A/S-4’s input of Clear to Send is high on the modem port. This light

 

must be on for the A/S-4 to transmit data on the modem port.

MCD

Lights when the A/S-4’s input of Carrier Detect is high on the modem port. This light

 

must be on while the MRX is flashing for the A/S-4 to process received data

MRX

Flashes as data is received by the A/S-4 from the modem port.

MTX

Flashes as data is transmitted by the A/S-4 out the modem port.

19

Image 20 Contents
Protocol Converter Model A/S-4 FCC Statement Protocol Converter Model A/S-4 Trademarks Contents Contents General Information General Information Specifications Indicators PowerInstallation 1General InstallationModem Interface Terminal Automatic Speed DetectionPower Transformer SynchronizerSwitches Terminal SwitchesCLEAR-TO-SEND Carrier DetectREQUEST-TO-SEND Baud Rate How to Set Terminal Port Switches for Different Devices DevicesModem Switches REQUEST-TO-SEND How to Set Modem Port Switches for Different Devices Option Switches LED Indicator Power Up and Configuration Menu Operations Power UpPower Up Message Type Home for VDU Match or Space VersionProtocol Converter Main Menu RUN no Changes Else Change VDU A/S-4 Main MenuCurrent Switching from A/S-4’s Main Menu to Running the Application Protocol Converter Model A/S-4 Changing the VDU Type CurrentVDU = NEW VDU Changing VDU Commands for the VDU Type Selected Changing Video Attributes and Commands for VDU ESC X Y Z 4 Standard Keyboard Layout Power Up and Configuration Menu Options ADM 1178 Keyboard Layout IBM 3101 Keyboard Layout PNS Keyboard Layout Changing Keyboard Layout Type Protocol Converter Model A/S-4 ESC or =PF20 PA Keys CTL Z or Protocol Converter Model A/S-4 Changing Application Changing Application OptionsDo not set the VDU and PRT LU addresses to the same values XON/XOFF=OFF Changing Batch Application Options Printer Options Current Power Up and Configuration Menu Options Programmable Printer Options Verify Switch Settings Reload Default Options Interactive Operation Batch Operation Batch Operation Receiving Batch Data from the SNA hostSOF ETX Transmitting Batch Data to the SNA HostSTX Batch Printer Operation Batch Operation Batch Default Options 1ST Char from VDU Device Indicator LU AddressCustomer Option a BIT 7 Terminate Message to VDU on 1-END of ChainInbound LU XFR Char Option not UsedLU Address not Used Customer Option CDefault CRT = Ascii STANDARD, VT100 Default Kybd = StandardApplication Options C5D3 = Lear Siegler ADM 3AEND of Options Battery RAM Maintenance Software Upgrade and Eprom Replacement System/Line Gen for Batch Transfer = Modetab = Instinclm Sscpfm = UssscsVpacing = Addr = C1Setupmsg Setupinf Usstab = RjeincdtIstatus = Active Buffact =Waitime = OperatorCctl Ckptlns =Operator Cctl Ckptlns = Cmpct CompNosep Select = PUNCH1 Nohold Nosep StartPudest = Pulcl Punode Xeonode = Adiscon Codea Comp EbcdicIfacea Lowspeed TranspPrtrans = YES Modeent LOGMODE=BUF512,FMPROF=X’03’,TSPROF=X’03’Modeent LOGMODE=BUF256,FMPROF=X’03’,TSPROF=X’03’ Compact Modeent LOGMODE=COMPACT,FMPROF=X’03’,TSPROF=X’03’Ussparm PARM-APPLID,DEFAULT=JES2 Ussparm PARM=LOGMODE,DEFAULT=BATCHUssparm PARM=LOGMODE,DEFAULT=MOCOMP Usscmd CMD=RMT101,REP=LOGON,FORMAT=BALTroubleshooting Problems and Odd Installation Problems Problem Symptom Possible RemediesTroubleshooting Problems and Odd Installation Problems Appendix a 3274 SNA Communication Operations Appendix a 3274 SNA Communication Operations Appendix B General 3770 SNA Communication Operations Appendix B General 3770 SNA Communication Operations Appendix C Conversion Charts Appendix C Conversion Charts Protocol Converter Model A/S-4 Appendix C Conversion Charts Protocol Converter Model A/S-4 Recv Conv Protocol Converter Model A/S-4 Park Drive Lawrence, PA