Black Box A/S-4 manual ESC or =PF20

Page 38

CHAPTER 6: Power Up and Configuration Menu Options

6.9.1 PF KEYS

Selection of item B from the menu shown in Figure 9 will cause the menu shown in Figure 10 to be displayed.

If the operator wants to use a different key for PF2, he would first enter the letter “C” and then enter the new value(s) in response to prompt(S) for the new value(s). The key sequences entered for the PF keys must be either control or escape sequences to work properly, and any specific key sequence must be entered for only one key. After a new value has been entered, the menu will be redisplayed and will show the new value(s).

CURRENT:

Application = SDLC/SNA 3274/76 Interactive

VDU = ANSI STD; DEC VT100; Teletype 5410, 5420; Televdeo 970, 960

Keyboard = STANDARD

Change: PF Keys (Keys Typed on VDU to Perform Function)

A-Exit

B-ESC Q or ESC q=PF1

C-ESC W or ESC w=PF2

D-ESC E or ESC e=PF3

E-ESC R or ESC r=PF4

F-ESC T or ESC t=PF5

G-ESC Y or ESC y=PF6

H-ESC U or ESC u=PF7

I-ESC I or ESC i=PF8

J-ESC O or ESC o=PF9

K-ESC P or ESC P=OF10

L-ESC A or ESC a=PF11

M-ESC S or ESC S=PF12

N-ESC D or ESC d=PF13

O-ESC F or ESC f=PF14

P-ESC G or ESC g=PF15

Q-ESC H or ESC h=PF16

R-ESC J or ESC j=PF17

S-ESC K or ESC k=PF18

T-ESC L or ESC l=PF19

U-ESC ; or =PF20

V-ESC Z or ESC z=PF21

W-ESC X or ESC x=Pf22

X-ESC C or ESC c=PF23

Y-ESC V or ESC v=PF24

 

Enter Letter:

 

 

 

 

Figure 10

37

Image 38
Contents Protocol Converter Model A/S-4 FCC Statement Protocol Converter Model A/S-4 Trademarks Contents Contents General Information General Information Specifications Indicators PowerModem Interface Installation1General Installation Terminal Automatic Speed DetectionPower Transformer SynchronizerCLEAR-TO-SEND SwitchesTerminal Switches Carrier DetectREQUEST-TO-SEND Baud Rate How to Set Terminal Port Switches for Different Devices DevicesModem Switches REQUEST-TO-SEND How to Set Modem Port Switches for Different Devices Option Switches LED Indicator Power Up and Configuration Menu Operations Power UpPower Up Message Type Home for VDU Match or Space VersionProtocol Converter Main Menu RUN no Changes Else Change VDU A/S-4 Main MenuCurrent Switching from A/S-4’s Main Menu to Running the Application Protocol Converter Model A/S-4 Changing the VDU Type CurrentVDU = NEW VDU Changing VDU Commands for the VDU Type Selected Changing Video Attributes and Commands for VDU ESC X Y Z 4 Standard Keyboard Layout Power Up and Configuration Menu Options ADM 1178 Keyboard Layout IBM 3101 Keyboard Layout PNS Keyboard Layout Changing Keyboard Layout Type Protocol Converter Model A/S-4 ESC or =PF20 PA Keys CTL Z or Protocol Converter Model A/S-4 Changing Application Changing Application OptionsDo not set the VDU and PRT LU addresses to the same values XON/XOFF=OFF Changing Batch Application Options Printer Options Current Power Up and Configuration Menu Options Programmable Printer Options Verify Switch Settings Reload Default Options Interactive Operation Batch Operation Batch Operation Receiving Batch Data from the SNA hostSOF ETX Transmitting Batch Data to the SNA HostSTX Batch Printer Operation Batch Operation Batch Default Options Customer Option a 1ST Char from VDU Device IndicatorLU Address BIT 7 Terminate Message to VDU on 1-END of ChainLU Address not Used Inbound LU XFRChar Option not Used Customer Option CApplication Options Default CRT = Ascii STANDARD, VT100Default Kybd = Standard C5D3 = Lear Siegler ADM 3AEND of Options Battery RAM Maintenance Software Upgrade and Eprom Replacement System/Line Gen for Batch Vpacing = Transfer = Modetab = InstinclmSscpfm = Ussscs Addr = C1Istatus = Active Setupmsg SetupinfUsstab = Rjeincdt Buffact =Cctl Waitime =Operator Ckptlns =Nosep Select = PUNCH1 Operator Cctl Ckptlns =Cmpct Comp Nohold Nosep StartIfacea Lowspeed Pudest = Pulcl Punode Xeonode =Adiscon Codea Comp Ebcdic TranspModeent LOGMODE=BUF256,FMPROF=X’03’,TSPROF=X’03’ Prtrans = YESModeent LOGMODE=BUF512,FMPROF=X’03’,TSPROF=X’03’ Compact Modeent LOGMODE=COMPACT,FMPROF=X’03’,TSPROF=X’03’Ussparm PARM=LOGMODE,DEFAULT=MOCOMP Ussparm PARM-APPLID,DEFAULT=JES2Ussparm PARM=LOGMODE,DEFAULT=BATCH Usscmd CMD=RMT101,REP=LOGON,FORMAT=BALTroubleshooting Problems and Odd Installation Problems Problem Symptom Possible RemediesTroubleshooting Problems and Odd Installation Problems Appendix a 3274 SNA Communication Operations Appendix a 3274 SNA Communication Operations Appendix B General 3770 SNA Communication Operations Appendix B General 3770 SNA Communication Operations Appendix C Conversion Charts Appendix C Conversion Charts Protocol Converter Model A/S-4 Appendix C Conversion Charts Protocol Converter Model A/S-4 Recv Conv Protocol Converter Model A/S-4 Park Drive Lawrence, PA