Black Box A/S-4 manual Do not set the VDU and PRT LU addresses to the same values

Page 43

PROTOCOL CONVERTER MODEL A/S-4

6.11.1CHANGING INTERACTIVE APPLICATION OPTIONS

The change Application menu allows 8 operations as described below:

A. Exit - By entering the letter A the A/S-4 will return to the Main Menu.

B.XID - By entering a B the operator is able to change the A/S-4 SDLC control unit identifier. Only hexadecimal numbers are allowed to be entered for this selection, the first two digits are fixed at 01. The next character indicates what type of device the A/S-4 (7=3274, 8=3276, 0=3774, 1=3774P, 2=3771 and 3=3776/77).

C.PU Addr - To change the units physical unit address enter C. Only hexadecimal numbers are allowed to be entered for this selection; addresses x’00’-SSCP address and x’FF’-Global SDLC address can not be used.

D.SDLC Baud Rate - By entering a D the operator can select the baud rate at which the host will transmit and receive data from the A/S-4. This selection is only used when running SDLC over asynchronous modems or when the A/S-4 is supplying clocks to a front end processor. After entering the letter D the current baud rate will be displayed. To change it, enter the letter Y which will scroll pass each selectable baud rate, when the correct rate is displayed entering any key other than the Y will save the new baud rate.

NOTE

SDLC baud rate has no effect when running with synchronous modems.

E.XON/OFF - Entering an E allows the selecting of the DC1 (XON), DC3 (XOFF) protocol on the A/S-4’s terminal port. This protocol can be used; TO the unit or FROM the unit or in BOTH directions. To disable the XON/OFF protocol, select the option for OFF by the use of the letter Y, entering any key will save the selection. This protocol is used so the A/S-4 or the attached async device will not overflow each others buffers with data. If the A/S-4 has room to store only 20 characters from the VDU, the unit will drop it’s RTS signal (can be connected to pin 4, 5, 11, 19 or 20 of EIA connector) and send an XOFF character if option is set for FROM or BOTH. When the A/S-4 is sending data to the VDU, the VDU can stop the flow by dropping it’s signal connected to the A/S- 4’s CTS or by sending a XOFF character, if the A/S-4’s XON/XOFF option is set for TO or BOTH.

F.VDU LU Addr - The VDU LU address can be changed by entering the letter F. For this selection only hexadecimal numbers are allowed to be entered, from the range of X’01’ to X’FF’ but for most installations the address range of the specific type of control unit is as follows:

IBM* 3274 = X’02’-X’21’

IBM* 3276 = X’02’-X’09’

IBM* 3776 Model 3 and 4 = X’01’-’06’

NOTE

Do not set the VDU and PRT LU addresses to the same values.

42

Image 43 Contents
Protocol Converter Model A/S-4 FCC Statement Protocol Converter Model A/S-4 Trademarks Contents Contents General Information General Information Indicators Power SpecificationsTerminal Automatic Speed Detection Installation1General Installation Modem InterfaceSynchronizer Power TransformerCarrier Detect SwitchesTerminal Switches CLEAR-TO-SENDREQUEST-TO-SEND Baud Rate Devices How to Set Terminal Port Switches for Different DevicesModem Switches REQUEST-TO-SEND How to Set Modem Port Switches for Different Devices Option Switches LED Indicator Power Up Power Up and Configuration Menu OperationsType Home for VDU Match or Space Version Power Up MessageCurrent A/S-4 Main MenuProtocol Converter Main Menu RUN no Changes Else Change VDU Switching from A/S-4’s Main Menu to Running the Application Protocol Converter Model A/S-4 Current Changing the VDU TypeVDU = NEW VDU Changing VDU Commands for the VDU Type Selected Changing Video Attributes and Commands for VDU ESC X Y Z 4 Standard Keyboard Layout Power Up and Configuration Menu Options ADM 1178 Keyboard Layout IBM 3101 Keyboard Layout PNS Keyboard Layout Changing Keyboard Layout Type Protocol Converter Model A/S-4 ESC or =PF20 PA Keys CTL Z or Protocol Converter Model A/S-4 Changing Application Options Changing ApplicationDo not set the VDU and PRT LU addresses to the same values XON/XOFF=OFF Changing Batch Application Options Printer Options Current Power Up and Configuration Menu Options Programmable Printer Options Verify Switch Settings Reload Default Options Interactive Operation Batch Operation Receiving Batch Data from the SNA host Batch OperationSOF STX Transmitting Batch Data to the SNA HostETX Batch Printer Operation Batch Operation Batch Default Options BIT 7 Terminate Message to VDU on 1-END of Chain 1ST Char from VDU Device IndicatorLU Address Customer Option aCustomer Option C Inbound LU XFRChar Option not Used LU Address not UsedC5D3 = Lear Siegler ADM 3A Default CRT = Ascii STANDARD, VT100Default Kybd = Standard Application OptionsEND of Options Battery RAM Maintenance Software Upgrade and Eprom Replacement System/Line Gen for Batch Addr = C1 Transfer = Modetab = InstinclmSscpfm = Ussscs Vpacing =Buffact = Setupmsg SetupinfUsstab = Rjeincdt Istatus = ActiveCkptlns = Waitime =Operator CctlNohold Nosep Start Operator Cctl Ckptlns =Cmpct Comp Nosep Select = PUNCH1Transp Pudest = Pulcl Punode Xeonode =Adiscon Codea Comp Ebcdic Ifacea LowspeedCompact Modeent LOGMODE=COMPACT,FMPROF=X’03’,TSPROF=X’03’ Prtrans = YESModeent LOGMODE=BUF512,FMPROF=X’03’,TSPROF=X’03’ Modeent LOGMODE=BUF256,FMPROF=X’03’,TSPROF=X’03’Usscmd CMD=RMT101,REP=LOGON,FORMAT=BAL Ussparm PARM-APPLID,DEFAULT=JES2Ussparm PARM=LOGMODE,DEFAULT=BATCH Ussparm PARM=LOGMODE,DEFAULT=MOCOMPProblem Symptom Possible Remedies Troubleshooting Problems and Odd Installation ProblemsTroubleshooting Problems and Odd Installation Problems Appendix a 3274 SNA Communication Operations Appendix a 3274 SNA Communication Operations Appendix B General 3770 SNA Communication Operations Appendix B General 3770 SNA Communication Operations Appendix C Conversion Charts Appendix C Conversion Charts Protocol Converter Model A/S-4 Appendix C Conversion Charts Protocol Converter Model A/S-4 Recv Conv Protocol Converter Model A/S-4 Park Drive Lawrence, PA