Installer Menu
Use the Installer’s Menu to set up or change operational settings.
See more detailed descriptions of the Installer menu items on the following pages...
Accessing the Installer’s Menu
Make sure TV is on. Installer’s menu items can be accessed by using an installer’s remote control. Just press MENU repeatedly (at least 10 times) until the TV seems to stop responding, then press 9, 8, 7, 6, then ENTER to access the Installer’s menu. To remove the Installer’s menu, press ENTER again. Any changes you make will be stored in non- volatile memory. (The menu also disappears automatically.)
The Installer’s menu opens with item 000 INSTALLER SEQ 000. Use the Up/Down arrow keys to sequence through the available menu items. Or, access an item directly by keying in the line number, then pressing MENU. For example, to access the Sleep Timer option which is item 015, press
Using the Installer’s Menu
Items 000 ~ 117 are immediately accessible only upon entering the Installer’s Menu. Their numbers, descriptions, ranges, factory default settings, and a place for listing any changes made
Installer Menu Items 000 through 117
L20V54S PTC INSTALLER MENU
000 | INSTALLER SEQ | 000 |
|
|
|
UPN | FPGA 09F1 | |
PTC V1.00.000 | CPU V1.01.00 | |
|
|
|
Typical Installer Menu
Menu Item | Function | Value Range | Default Value | Brief Description of Function and Comments | |
000 | INSTALLER SEQ | 0 | ~ 3 | 0 | Leave default set to 0. |
|
|
|
|
|
|
001 | POWER MANAGE | 0 | ~ 7 | 0 | Sets number of hours of no activity before auto shut Off. |
|
|
|
|
| |
002 | AC ON | 0 / 1 | 0 | Set to 1 to enable auto turn On at power up. | |
|
|
|
|
|
|
003 | BAND/AFC | 0 | ~ 3 | 1 | Selects Tuning Band: 0=Broadcast, 1=CATV, 2=HRC, 3=IRC |
|
|
|
|
| |
004 | STRT CHANNEL | 0 ~ 127, 255 | 255 | Channel at | |
|
|
|
|
| |
005 | CHAN LOCK | 0 / 1 | 0 | If set to 1, cannot tune from current channel. | |
|
|
|
|
| |
007 | STRT VOLUME | 0 ~ 63, 255 | 255 | Sets Volume level at TV | |
|
|
|
|
| |
008 | MIN VOLUME | 0 ~ 63 | 0 | Sets minimum allowable volume setting. | |
|
|
|
|
| |
009 | MAX VOLUME | 0 ~ 63 | 63 | Sets maximum allowable volume setting. | |
|
|
|
|
| |
010 | MUTE DISABLE | 0 / 1 | 0 | Set to 1 to disable mute function. | |
|
|
|
|
| |
011 | KEY DEFEAT | 0 / 1 | 1 | Set to 1 to disable menu navigation keys on display panel. | |
|
|
|
|
| |
012 | IR BANKS EN. | 0 / 1 | 0 | Set to 1: enables TV to respond to IR code | |
|
|
|
|
| |
013 | SCAN MODE | 0 / 1 | 1 | Typically used for Hospitals: puts | |
|
|
|
|
| |
014 | STRT CH IN SM | 0 / 1 | 0 | Set to 1 to put TV on/off below start channel number. | |
|
|
|
|
| |
015 | SLEEP TIMER | 0 / 1 | 1 | Set to 1 to enable Sleep Timer. | |
|
|
|
|
| |
016 | EN TIMER | 0 / 1 | 1 | Set to 1 to enable On/Off Timers. | |
|
|
|
|
| |
017 | ALARM | 0 / 1 | 1 | Set to 1 to enable Alarm. | |
|
|
|
|
| |
020 | FEATURE LEVEL | 0 / 1 | 1 | Zen 1 Leave default set 1 (1 Zen 1) | |
|
|
|
|
| |
021 | 0 / 1 | 1 | Set to 1 to enable | ||
|
|
|
|
| |
022 | MAX BLK HRS | 0 ~ 99 | 12 | Sets number of | |
|
|
|
|
| |
023 | CAPTION LOCK | 0 / 1 | 0 | Set to 1 to retain caption setting at power Off. | |
|
|
|
|
|
|
025 | FUNCTION PRE. | 0 | ~ 3 | 1 | Controls channel preview in |
|
|
|
|
|
|
027 | HOSPITAL MODE | 0 | ~ 2 | 2 | Leave default set to 2. |
|
|
|
|
| |
028 | CH. OVERIDE | 0 / 1 | 1 | If set to 0, limits direct access to favorite channels. | |
|
|
|
|
| |
029 | OLD OCV | 0 / 1 | 0 | Set to 1 to change M.P.I. operation to OCV. | |
|
|
|
|
| |
030 | ACK MASK | 0 / 1 | 0 | If set to 1, changes M.P.I. for some OCV boxes. | |
|
|
|
|
| |
031 | POLL RATE | 20 ~ 169 | 94 | Selects poll rate for M.P.I. | |
|
|
|
|
|
|
032 | TIMING PULSE | 186 | ~ 227 | 207 | Sets baud rate for M.P.I. |
|
|
|
|
|
|