Installer Menu
(Continued from previous page)
The value range is 0 to 63, with 63 as the default, which gives the user the full range of volume control, if item 008 MIN VOLUME is also set at 0. Change values with ADJ Left/Right arrow keys. It may be best to set the same value on every L20V54S.
*Note: The maximum volume level cannot have a value setting lower than the MIN VOLUME level (described previously).
010 - MUTE DISABLE
Enables or disables sound mute function. If set to 1, sound cannot be muted, mute is disabled. If set to 0, sound can be muted.
011 - KEY DEFEAT (Keyboard Defeat)
If set to 1, key defeat prevents the end user from accessing the on- screen menus with the display front
*Note: The menus can always be accessed by pressing MENU on the remote.
012 - IR BANKS EN. (IR Banks Enable)
For direct access to a particular Channel Bank. When enabled, installer can access a channel bank by inputting the IR code for the bank.
013 - SCAN MODE
Allows variation in setting the On/Off with Channel UP/DOWN. You may opt for TV channels only; TV channels + Off/ON; TV channels + FM radio; TV channels + FM radio + Off/On with these set- tings for Scan Mode:
SCAN MODE | Characteristics |
0Channel up/down keys change channels only.
1Channel down below the lowest channel
(or channel up higher than the highest) and TV turns off.
014 - STRT CH IN SM (Start Channel in Scan Mode)
When set to 1, installs TV On/Off event below the start channelat TV turn on.
015 - SLEEP TIMER
If set to 1, the SLEEP TIMER feature may be used. If set to 0, the Sleep Timer is not available.
016 - EN TIMER (Enable On/Off Timers)
If set to 1, Timer function is available to user. Set to 0 to disable On/Off Timer functions. (Clock must be set in order to use Timers.)
017 - ALARM
Gives the installer the option of making the Alarm function available to the end user. If set to 1, Alarm function is available to end user. Set to 0 to disable the Alarm function.
*Note: Clock must be set before the Alarm function will work.
Installer should leave item 20 FEATURE LEVEL set to 1 (default).
020 - FEATURE LEVEL
Default set to ZEN 1 for Zenith IR remote control opera- tion. Set O, P LBL for Zenith Private Label IR remote con- trol operation. Warning: Do not set to “0” or remote will not control TV.
021 - V-CHIP (Parental Control)
Set to 1 to activate
022 - MAX BLK HRS (Maximum Block Hours)
Sets hours from 0 to 99 for the maximum
023 - CAPTION LOCK
Set to 1 to restore previous caption On/Off state after turn Off. If set to 0, captions are always Off at turn On.
025 - FUNCTION PRE. (Function Preview)
Set to 0 to suppress CHANNEL PREVIEW from the FUNCTION menu with some
027 - HOSPITAL MODE
The default is 2 (which favors most hospitals). With this setting two things are affected: Channel Banks 1, 2, and 3 are accessible, while Bank 4 is inactive.
028 - CH. OVERIDE (Channel Override)
If set to 1, the user can select channels with either Channel up/down or by direct keypad entry. If set to 0, only those channels that are entered for scanning can be selected.
029 - OLD OCV (On Command VideoTM)
Set to 1 for operation with systems from On Command Corporation.
030 - ACK MASK
M.P.I. Communication Parameter. Leave at default setting unless changed by
031 - POLL RATE
M.P.I. Communication Parameter. Selects Poll Rate for M.P.I. Leave at default setting unless changed by
032 - TIMING PULSE
M.P.I. Communication Parameter. Leave at default setting unless changed by
035 - COMPPORT EN. (Computer Port Enable)
Enable/disables display panel HDMI input jack. Set to 0 to disable, set to 1 to enable.