IMPORTANT SAFEGUARDS

Caution Concerning the Lamp Replacement

There is potential glass particle hazard if the lamp ruptures.

Caution Concerning the Lamp Unit

There is a potential hazard of glass particle if the lamp ruptures.

In case of lamp rupture,contact your nearest Marantz Authorized Dealer or Service Center for a replacement.

See “Replacing Lamp Unit”. (P.31)

WARNING

CAUTION :

CAUTION HOT :

 

MODEL NO. VP-16S1/U1M

 

AC 120V 60HZ 2.0A

ATTENTION :

ATTENTION CHAUD : SERIAL NO.

Caution

Concerning the Setup of the Projector

For minimal servicing and to maintain high image quality, avoid humidity, dust and cigarette smoke.

When the projector is subjected to these environments,the lens and part of ventilation holes must be cleaned more often than usual. As long as the projector is properly maintained in this manner, use in these environments will not reduce the overall operation life. Please note that all internal cleaning must be performed by an Marantz Authorized Dealer, or Service Center.

Do not expose the projector to extreme heat or cold. Operating temperature:41 °F to 95 °F (+5 °C to 35 °C) Storage temperature:–4 °F to 140 °F (–20 °C to +60 °C)

95˚F

(+35˚C)

41˚F

(+5˚C)

Notes on Operation

For USA

WARNING

THIS COVER IS PROVIDED WITH INTERLOCK TO REDUCE THE RISK OF EXCESSIVE ULTRAVIOLET RADIATION. DO NOT DEFEAT ITS PORPOSE OR ATTEMPT TO SERVICE WITHOUT REMOVING COVER COMPLETELY.

For Europe

CAUTION HOT

UNPLUG THE POWER CORD AND

For USA

CAUTION : HIGH PRESSURE LAMP MAY EXPLODED IF IMPROPERLY HANDLED. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

ATTENTION : LA LAMPE SOUS HAUTE PRESSION PEUT SI ELLE, N'EST PAS MANIPULEE CORRECTEMENT, CONFIER L'OPERATION A UN PERSONNEL D'ENTRETIEN QUALIFIE.

CAUTION HOT : UNPLUG

THE POWER CORD AND WAIT M

60 MINUTES BEFORE CHARGING THE LAMP.

ATTENTION CHAUD :

DEBRANCER LE CORD ON D'ALOMENTION ET ATENDER 60 MINUTES AVANT DE CHANGER LAMPE.

The exhaust ventilative hole, the lamp cage cover and adjacent areas may get extremely hot during projector operation. To prevent injury,do not touch these areas until they have sufficiently cooled down.

Allow at least 1 foot (30 cm)of space between the exhaust ventilative hole and the nearest wall or obstruction.

If the cooling fan becomes obstructed, a protection device will automatically turn off the projector lamp. This does not indicate a malfunction. Remove the projector power cord from the wall outlet and wait at least 10 minutes.

Then turn on the power by plugging the power cord back in. This will return the projector to the normal operating condition.

WAIT 60 MINUTES BEFORE CHANGING THE LAMP.

ATTENTION CHAUD

DEBRANCER LE CORD ON D'ALIMENTION ET ATENDER 60 MINUTES AVANT DE CHANGER LAMPE.

WARNUNG HEISS

ZIEHEN SIE DEN NETZSTECKER

AB UND WARTEN SIE 60 MINUTEN, BEVOR SIE DIE GLUHLAMPE WECHSELN.

For Europe

CAUTION

VORSICHT :

HIGH PRESSURE LAMP MAY EXPLODED IF

BEI FALSCHER HANDHABUNG M

IMPROPERLY HANDLED. REFER SERVICING

KANN DIE HOCHDRUCKLAMPE

TO QUALIFIED SERVICE PERSONNEL.

EXPLODIEREN UBERLASSEN

ATTENTION

SIE WARTUNGSARBEITEN

NUR FACHPERSONAL.

LA LAMPE SOUS HAUTE PRESSION PEUT

 

EXPLOSER SI ELLE, N'EST PAS MANIPULEE

 

CORRECTEMENT, CONFIER L'OPERATION

 

A UN PERSONNEL D'ENTRETIEN QUALIFIE.

 

2

Image 10
Contents Model VP-11S2 User Guide Additional Safety Information Read Before Operating EquipmentEnglish Français Español Português Deutsch Kongeriket Norge ItalianoSuomi SvenskaTable of Contents Warnung Heiss Important SafeguardsVorsicht Features AccessoriesProjector Layout and Functional Overview Adjust the picture focusFront and Top View Rear and Terminals View Ventilation holes intake Adjustable Feet Adjustable feetBottom View Remote Controller £9PATTERN button P.11 Remote Controller Operational Range VP-11S2When pulling out a cable Connection with AC Power SupplyWhen making connections be sure to ConnectionCompatible PC Advanced ConnectionHD-Video / Satellite Cable Tuner / DVD Player ScreenZooming and Focusing Initial SettingTurning on the Power Detail FocusingKeystone Correction Adjusting the Image PositionAdjusting the Height Returning the Projector to its Initial PositionInstalling on a tabletop InstallationRecommended Setting Mounting on the ceiling16 9 Screen Screen Size and Projection Distance inch VP-11S2Screen Size and Projection Distance mm VP-11S2 ScreenScreen Size and Projection Distance inch VP-11S2L Screen Size and Projection Distance mm VP-11S2LStandard condition From -85% to +100% Lens shift position VP-11S2Extended mounting condition From +100% to +165% Lens shift position VP-11S2L Standard condition From -85% to +165%Selecting the Input Signal Source Selecting the Aspect ModeBasic Operations Screen Images in a 169 screen To Turn off the Power Screen Images in a 43 screenOperations Menu StructureFunctions by Signal Component RGB Hdmi ANY Input Ntsc PAL/SECAMNo Signal Valid Signal ANY Input Memorizing settings in an index Picture ModeAdjustment bar Picture Adjust FRC Fine MenuCEC Hdmi 1, Hdmi Input Signal RGB/HD AdjustRGB NTSCNTSC-3.58Display OSD/Blanking Adjustments Menu PositionBlanking Top, Bottom, Left and Right Configration Lamp Life and Replace Lamp MaintenanceReplacing Lamp Unit Wait at the least one hour for the lamp Optional Accessories Cleaning the LensReplacement Parts Lamp Unit LU-12VPS3 Ceiling Mount kit MountTroubleshooting On Screen Message Error ModeBlack Level Black setup GlossaryTiming chart Optical characteristicsAccessories Input/OutputVP-11S2 DimensionsVP-11S2L Page Is a registered trademark