After correcting the original service problem, perform the following safety checks before releasing the set to the customer:

1.Check the area of your repair for unsoldered or poorly soldered connections. Check the entire board surface for solder splashes and bridges.

2.Check the interboard wiring to ensure that no wires are “pinched” or touching high-wattage resistors.

3.Check that all control knobs, shields, covers, ground straps, and mounting hardware have been replaced. Be absolutely certain that you have replaced all the insulators.

4.Look for unauthorized replacement parts, particularly transistors, that were installed during a previous repair. Point them out to the customer and recommend their replacement.

5.Look for parts which, though functioning, show obvious signs of deterioration. Point them out to the customer and recommend their replacement.

6.Check the line cords for cracks and abrasion. Recommend the replacement of any such line cord to the customer.

7.Check the B+ and HV to see if they are specified values. Make sure your instruments are accurate; be suspicious of your HV meter if sets always have low HV.

8.Check the antenna terminals, metal trim, “metallized” knobs, screws, and all other exposed metal parts for AC leakage. Check leakage as described below.

Leakage Test

To Exposed Metal

Parts on Set

0.15 F

 

 

 

1.5 K

AC

 

 

 

 

 

 

 

 

Voltmeter

 

 

 

 

 

(0.75 V)

 

 

 

 

 

 

Earth Ground

Figure A. Using an AC voltmeter to check AC leakage.

The AC leakage from any exposed metal part to earth ground and from all exposed metal parts to any exposed metal part having a return to chassis, must not exceed 0.5 mA (500 microamperes). Leakage current can be measured by any one of three methods.

1.A commercial leakage tester, such as the Simpson 229 or RCA WT-540A. Follow the manufacturers’ instructions to use these instructions.

2.A battery-operated AC milliampmeter. The Data Precision 245 digital multimeter is suitable for this job.

3.Measuring the voltage drop across a resistor by means of a VOM or battery-operated AC voltmeter. The “limit” indication is 0.75

V, so analog meters must have an accurate low voltage scale. The Simpson’s 250 and Sanwa SH-63TRD are examples of passive VOMs that are suitable. Nearly all battery-operated digital multimeters that have a 2 VAC range are suitable (see Figure A).

How to Find a Good Earth Ground

A cold-water pipe is a guaranteed earth ground; the cover-plate retaining screw on most AC outlet boxes is also at earth ground. If the retaining screw is to be used as your earth ground, verify that it is at ground by measuring the resistance between it and a cold-water pipe with an ohmmeter. The reading should be zero ohms.

If a cold-water pipe is not accessible, connect a 60- to 100-watt trouble- light (not a neon lamp) between the hot side of the receptacle and the retaining screw. Try both slots, if necessary, to locate the hot side on the line; the lamp should light at normal brilliance if the screw is at ground potential (see Figure B).

Trouble Light

Ohmmeter

AC Outlet Box

Cold-water Pipe

Figure B. Checking for earth ground.

KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120

7

Image 6
Contents Trinitron Color Television Table of Contents Specifications SRS Sound Retrieval SystemTelevision system SAFETY-RELATED Component Warning Safety CHECK-OUT Leakage TestSELF-DIAGNOSTIC Function LED OFFFrom Hldwn Board BoardChroma Jungle OUT System Memory From IO-BDAT Board IK-AKBIN DisplayDisassembly Chassis Assembly RemovalRear Cover Removal KV-27FS320 Pictured Service Position KV-27FS320 Pictured HOW to Handle AN Anode CAP Anode CAP Removal ProcedureRemoval Procedures Picture Tube RemovalCable Wire Dressing KV-27FS320/32FS320/36FS320 Models Data not AvailableDress RGB harness over Rotation coil lead wire KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120 KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120 Dress lightning wire under 12P harness KV-36FS120/38FS120 Models Dress earth groun wires under DGC and over VD board KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120 Dress DY lead wire with a 9mm purse lock KV-27FS320/32FS120/32FS320/34FS120/36FS120/36FS320/38FS120 SET-UP Adjustments Adjustment ProcedureBeam Landing Horizontal Static Convergence ConvergenceVertical Static Convergence StatDynamic Convergence Adjustment TLH Plate AdjustmentSCREEN-CORNER Convergence Service Adjustment Mode on Service Adjustment Mode MemoryWhite Balance Adjustments HOLD-DOWN Operation Confirmation Adjustment Safety Related AdjustmentsReadjustments Preparation Before ConfirmationSetting the Service Adjustment Mode Circuit AdjustmentsElectrical Adjustments by Remote Commander Remote Adjustment Buttons and IndicatorsService Data Lists KV-27FS320 Service Data Data not AvailableKV-32FS320 Service Data VP1 ABL GainSUB Contrast Level Rdrv DriveSUB Sharpness Gainpre RF/VIDEO Axis Phase OffsetSUB Sharpness Gainover RF/VIDEO AKB onCdly Delay VM DelayDelay Time VP2Ynrc ScolSharpness Noise Coring Shcl VmclAKB Mode Clpt Clamp Auto on Keep TimerAmut RGB Power on Mute UVG UV Offset Canceler onRamp Filter Switching OFF XF0A Vcxo Freerun AdjustXpha Vcxo Phase Adjust Hffr AFC1 Force FreerunWeak Signal Video ATT Adcd ADC CLK Delay AdjustWsth Weaksignal VTH Weak Signal Chroma ATTBbth StreBbtl VfixKV-36FS320 Service Data YUV Fix/ Var VP2 Vivid Movie PRO169 Shrink Mode for AV-NoSync KV-36FS320 Service Data Audio output fix data KV-32FS120/34FS120 Service Data VP1 Rdrv Drive Gdrv BdrvBON BllvAKB on Refp Vmlo Ydly Delay Time Cdly Yoff Output Mute BgppVP2 Vmof Nrch Noise DET VTH1 NrclVhue Shmx YnrcVcol VshaACC Time Constant Acth ROM HYS Ablg ABL Gain Akbm AKB ModeYnrs YNR on CoblJsww XF0A Vcxo Freerun Adjust BgstHfup Freerun Frequency Rpls REF VCO FB Loop Select SSMAdcd ADC CLK Delay Adjust Wsth Weaksignal VTH Spmt AKB Power on Mute ExitGYG Bbol SbalSRL BbohNorth ID-OCND SouthBoard Adjustments Frequency Free Run CheckSize Adjustment Vsiz Service Adjustment Mode Memory EnterSemiconductors 2SD2144S-TP-UVWExploded Views Chassis KV-27FS320/32FS320/36FS320 onlyHR BOARD, Mounted Picture Tube KV-27FS320/32FS320/36FS320 only GUIDE, Light MS Chassis KV-32FS120/34FS120/36FS120/38FS120 only HS BOARD, Mounted Picture Tube KV-32FS120/34FS120/36FS120/38FS120 only LABEL, Door Electrical Parts List CapacitorFilm Connector DiodeDiode D1NS4 Chip Conductor FuseJack CoilIC Link TransistorResistor R390 Metal Thermistor SwitchRelay TunerVariable Resistor Elect Chip Filter PST9143NLIC565 759-700-44 NJM2902M IC633 759-641-26 R044 R372 Crystal Diode RD15ESB2 R818 R1851 215-922-11 Diode DAN202K L1301 469-549-21 HM HR HU Resistor BridgeAccessories and Packing HU HD HSRemote Commander KV-32FS120/34FS120 onlyBA-6CHASSIS