4-6. A BOARD ADJUSTMENTS
H. Frequency (Free Run) Check
1.Input a TV mode (RF) with no signal.
2.Connect a frequency counter to base of Q501
3.Check H. Frequency for 15735 ± 200 Hz.
V. Frequency (Free Run) Check
1.Select video 1 with no signal input.
2.Set the conditions for a standard setting.
3.Connect the frequency counter to
4.Check that V. Frequency shows 60 ± 4 Hz.
Drive (SCON)
1.Input a
2.Set in Pro mode + PICTURE MAX.
3.Activate the Service Adjustment Mode.
4.Set GON and BON items. Using 3 and 6 set each to the following values. Leave RON set to Ò1Ó.
|
|
| Display | Item | |
|
|
| Data | ||
| Mode Category | Item | |||
|
|
| |||
|
|
|
|
|
|
Signal | service | video | rdrv | 26 |
|
|
|
|
|
| |
Type | ntsc |
|
|
|
|
|
|
|
|
| |
| vchp | 00000000 00000000 |
| ||
|
|
| |||
|
|
|
|
|
|
| R ON: | ON | (1) |
|
|
| G ON: | OFF | (0) |
|
|
| B ON: | OFF | (0) |
|
|
5.Connect an oscilloscope probe to C Board, CN705 pin3 (KR).
6.Select SCON with 1 and 4 .
7.Adjust the value of SCON with 3 and 6 for 92 ± 2Vpp.
92 + 2Vpp
8. Reset GON and BON values to Ò1Ó. |
| |
R ON: | ON | (1) |
G ON: | ON | (1) |
B ON: | ON | (1) |
9. Press MUTING then ENTER to save into the memory.
Display Position Adjustment (DISP)
1.Input a
2.Set to Service Adjustment Mode.
3.Select DISP with 1 and 4 .
4.Adjust values of DISP with 3 and 6 to adjust characters to the center.
5.Press MUTING then ENTER to save into the memory.
6.Check to see if the text is displayed on the screen.
Display Item
Mode Category Item Data
service micro disp 48
Signal |
|
Type | ntsc |
vchp 00000000 00000000
Sub Bright Adjustment (SBRT)
1.Input a monoscope signal.
2.Activate the Service Adjustment Mode.
3.Set the PICTURE and BRIGHTNESS to minimum.
4.Select the SBRT item with 1 and 4 .
5.Adjust the values of SBRT with 3 and 6 to obtain a faintly visible 20 IRE mark, after that increase +3 steps.
6.Press MUTING then ENTER to save into the memory.
Sub Hue, Sub Color Adjustment (SHUE, SCOL)
1.Input
2.Activate the Service Adjustment Mode.
3.Set (PIC) to Max and (COL) to 50%.
4. Connect an oscilloscope probe to C Board, CN705 pin 4 (Blue Out).
5.Select the SHUE and SCOL item with 1 and 4 .
6.While showing the SHUE item, adjust the waveform with 3 and 6 until the second and third bars show the same level
(V2 = V3 <
7.While showing the SCOL item, adjust the waveform with 3 and 6 until the Þrst and fourth bars show the same level
(V1 = V4 <
V1 V2 V3 V4
8. Press MUTING then ENTER to save into the memory.