SELF-DIAGNOSTIC FUNCTION
Self Diagnosis |
Supported model |
The units in this manual contain a
Diagnostic Test Indicators
When an error occurs, the STANDBY/TIMER LED will flash a set number of times to indicate the possible cause of the problem. If there is more than one error, the LED will identify the first of the problem areas.
Results for all of the following diagnostic items are displayed on screen. No error has occurred if the screen displays a “0”.
Diagnostic Item | No. of times | Probable Cause Location | Detected Symptoms | |||
Description | STANDBY/ TIMER |
| Display/ |
|
| |
| lamp flashes | Diagnostic Result |
|
| ||
Power does not turn on | Does not light |
|
|
| • Power cord is not plugged in. | • Power does not come on. |
|
|
|
|
| • Fuse is burned out (F601). (A Board) | • No power is supplied to the TV. |
|
|
|
|
| ||
|
|
|
|
|
| • AC Power supply is faulty. |
|
|
|
|
|
|
|
+B overcurrent (OCP)* | 2 times |
| 2:0 or 2:1 | • H.OUT (Q502) is shorted. (A Board) | • Power does not come on. | |
|
|
|
|
| • IC702 is shorted. (C Board) | • Load on power line is shorted. |
|
|
|
|
|
|
|
4 times |
| 4:0 or 4:1 | • +13V is not supplied. (A Board) | • Has entered standby state after horizontal raster. | ||
|
|
|
|
| • IC561 is faulty. (A Board) | • Vertical deflection pulse is stopped. |
|
|
|
|
|
| • Power line is shorted or power supply is stopped. |
|
|
|
|
|
|
|
IK (AKB) | 5 times |
| 5:0 or 5:1 | • IC001 is faulty. (M Board) | • No raster is generated. | |
|
|
|
|
| • Screen (G2) is improperly adjusted.** | • CRT Cathode current detection reference pulse |
|
|
|
|
|
| output is small. |
|
|
|
|
|
|
|
*If a +B overcurrent is detected, stoppage of the vertical deflection is detected simultaneously. The symptom that is diagnosed first by the mircrocontroller is displayed on the screen.
**Refer to Screen (G2) Adjustments in Section
Display of Standby/Timer LED Flash Count
2 times 4 times
5 times
LED ON 0.3 sec. |
|
|
|
|
|
|
|
|
| LED OFF | |||
LED OFF 0.3 sec. |
|
| ||||
|
| |||||
|
|
|
| 3 sec. | ||
|
|
| ||||
Diagnostic Item |
| Flash Count* |
Standby/Timer LED
+B Overcurrent | 2 times |
4 times | |
IK (AKB) | 5 times |
*One flash count is not used for
Stopping the Standby/Timer LED Flash
Turn off the power switch on the TV main unit or unplug the power cord from the outlet to stop the STANDBY/TIMER LAMP from flashing.
8 |