Panasonic TH-65PF10WK, TH-50PF10WK manual Advanced PIP, Options1/3

Page 24

Advanced PIP

1

2

3

4

Press to display the Setup menu.

Press to select “OSD Language”.

Press and hold until the Options menu is displayed. Press to select Advanced PIP.

5

Press to adjust the menu.

Off : Sets normal two screen display mode

(see page 23).

On : Sets Advanced PIP mode.

Options1/3

Weekly Command Timer

Onscreen display

 

On

 

 

 

Initial INPUT

 

Off

 

 

 

Initial VOL level

Off

0

 

 

 

Maximum VOL level

Off

0

 

 

 

INPUT lock

 

Off

 

 

 

Button lock

 

Off

 

 

 

Remocon User level

 

Off

 

 

 

Advanced PIP

 

Off

 

 

One screen

Advanced PIP

 

 

6

Press to exit from

 

 

 

 

 

Options menu.

Sub screen 1 Main screen

2

3

(When Advanced PIP is On)

 

 

 

 

 

7

 

 

6

5

4

Press repeatedly.

 

 

 

 

 

Each time pressing this button main picture and sub picture will be displayed as

 

above.

 

 

 

 

Note:

To use , , , buttons for the screen operations, follow the procedures in the previous page.

Notes:

If “INPUT lock” in Options menu is set to other than “Off”, MULTI PIP function isn’t available.

Sound output is from the picture which is selected in Audio OUT (PIP) (see page 27).

In 2 screen display, the same input mode cannot be selected for the main picture and sub picture.

The main picture and sub picture are processed by different circuits, resulting in a slight difference in the clarity of the pictures. There may also be a difference in the picture quality of the sub picture depending on the type of signals displayed on the main picture and depending on the 2-picture display mode.

Due to the small dimensions of the sub pictures, these sub pictures cannot be shown in detail.

Computer screen picture is displayed in a simplified format, and it may not be possible to discern details on them satisfactorily.

Following combinations of two analog signals cannot be displayed simultaneously;

Component - Component, Component - PC (RGB), PC (RGB) - Component, PC (RGB) - PC (RGB)

Refer to each board's operating instruction for DVI, SDI, HDMI's corresponding signals.

24

Image 24
Contents High Definition Plasma Display Operating InstructionsModel No. TH-50PF10WK EnglishTable of Contents Important Safety Notice Trademark CreditsSafety Precautions SetupDo not place any objects on top of the Plasma Display Transport only in upright positionSafety Precautions When using the Plasma DisplayIf problems occur during use Clean the power cable regularly to prevent it becoming dusty Electric shocks can result if this is not doneAccessories Accessories SupplyRemote Control Batteries Connections AC cord fixingMonitor terminal SeeConnections Optional TerminalBoard Insert Slot Equivalent of Dual Covered HDMITerminal Board BNC Component VideoSignal Names for Mini D-sub 15P Connector PC Input Terminals connectionCommand Serial Terminals connectionRS-232C Straight cable Communication parametersHdmi connection Component / RGB connectionPower On / Off Connecting the AC cord plug to the Plasma DisplayConnecting the plug to the Wall Outlet Power On / Off Selecting the input signal Initial selectionsSelecting the On-Screen Menu Language Remote control sensor Volume Adjustment Main Power On / Off Switch Power IndicatorBasic Controls Menu Screen on / OFFBasic Controls On-Screen Menu Displays On-Screen Menu Displays Mode Picture Explanation Aspect ControlsAdjusting Pos. /Size NormalisationAdjusting Pos. /Size Multi PIP Normal ViewingAdvanced PIP Options1/3Picture Adjustments NormalDynamic CinemaAdvanced settings Picture AdjustmentsSound Adjustment Sound Adjustment SDI Sound OutputMute On OffDigital Zoom Display the operation guideSelect the area of the image to be enlarged Select the magnification required for the enlarged displayPresent Time Setup / Set up Timer Present Time SetupPress to setup DAY or Present Time Button ForwardSet up Timer Present Time Setup / Set up TimerDisplay the Set up Timer screen Press to select Power on Time / Power OFF TimeMode selection Start settingScreensaver For preventing image retention Reversal / Scroll selectionSetup of Screensaver Time Reduces screen image retentionScreensaver For preventing image retention Side Panel Adjustment Reduces power consumption Customizing the Input labelsAddition sign Selected Input CompositeSetup for Multi Display How to Setup Multi DisplaySetup for Multi Display Display Number locations for each arrangement ExamplesID Remote Control Function ID remote control button operationID Cancellation AI-synchronizationSet up for Portrait How to setup PortraitSet up for Portrait Viewing Area / LocationSetup for Input Signals Component / RGB-in select3D Y/C Filter For Ntsc AV images Setup for Input Signals Press Action button Press to exit from adjust ModeNR / Block NR / Mosquito NR Refresh RateColour system / Panasonic Auto Cinema realitySetting RGB sync signal Press to exit from adjust mode Press Action ButtonSync Freq. kHz / V-Freq. HzOptions Adjustments Effect AdjustmentsOptions Adjustments Options1/3Off-timer Normalization Weekly Command Timer Press to select Time / Command Shipping condition Troubleshooting Plasma Display panelCOMPONENT/RGB/PC/VIDEO input signals COMPONENT/RGB/PC/VIDEO input signals Video input HdmiMHz Active pixels Pixels Active lines Lines Command list of Weekly Command Timer Specifications TH-50PF10WK TH-65PF10WKMemo Memo Memo Customer’s Record