Panasonic TH-42PR10UA Standby on / OFF button, Action button Press to make, Sound button

Page 15

Basic Controls

The remote control is not included with this set. Available for purchase separately.

Object model : EUR7636070R

Standby (ON / OFF) button

The Plasma Display must first be plugged into the wall outlet and turned on at the power switch (see page 12). Press ON to turn the Plasma Display On, from Standby mode. Press OFF to turn the Plasma Display Off

to Standby mode.R button (see page 17)

Press the R button to return to previous menu screen.

ACTION button Press to make

POSITION selections. buttons

SOUND button

(see page 24)

Status button

Press the “Status” button to display the current system status.

 

 

1

1

Input label

 

PC

 

 

 

NORMAL

2

2

Aspect mode (see page 18)

 

 

 

 

 

3

Off timer

 

 

 

 

The off timer indicator is

OFF TIMER 90

3

 

displayed only when the off

 

 

 

 

timer has been set.

SET UP button (see page 16, 17)

DIRECT INPUT buttons

Press the INPUT “1”, “2”, “3” or “PC” input mode selection button to select the INPUT mode.

This button is used to switch directly to INPUT mode.

These buttons can only display the slot which is installed. If you press the button whose slot is not installed, it automatically displays the current input signal. When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B)

Note:

Image retention (image lag) may occur on the plasma display panel when a still picture is kept on the panel for an extended period. The function that darkens the screen slightly is activated to prevent image retention (see page 42), this function is not the perfect solution to image retention.

Channel Adjustment

You can use this button when U/V Tuner Board with MATE I/F is installed (optional accessories). Refer to each Board’s Operating Instruction for detail.

Volume Adjustment

Press the Volume Up “+” or Down “–” button to increase or decrease the sound volume level.

OFF TIMER button

The Plasma Display can be preset to switch to stand-by after a fixed period. The setting changes to 30 minutes, 60 minutes, 90 minutes and 0 minutes (off timer cancelled) each time the button is pressed.

30 60 90

0

When three minutes remain, “OFF TIMER 3” will flash.

The off timer is cancelled if a power interruption occurs.

Digital Zoom (see page 25)

Press to access

Digital Zoom.

This displays an enlargement of the designated part of the displayed image.

15

Image 15
Contents Operating Instructions Manual de instrucciones English EspañolModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents FCC Caution Canadian NoticeTrademark Credits When using the Plasma Display Safety PrecautionsIf problems occur during use MaintenanceSetup AC Power Supply CordAccessories Accessories SuppliedCheck that you have the Accessories and items shown Optional Terminal Board Insert Slot covered ConnectionsAC cord connection see AC cord fixingPC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorBasic format for control data CommandSerial Terminals connection Communication parametersPower on / OFF Connecting the AC cord plug to the Plasma DisplayConnecting the plug to the Wall Outlet INPUT1 INPUT2 INPUT3 PC Selecting the input signalInitial selections Selecting the On-Screen Menu LanguageOn OFF Basic ControlsDigital Zoom see Press to access Channel AdjustmentVolume Adjustment OFF Timer buttonAdvanced Settings Picture Setup SoundOn-Screen Menu Displays On Time / Power OFF Time / Power OFF TimeNormal Full Aspect ControlsNormal Zoom Full Is pressed During Multi PIP OperationsRGB/PC in mode Adjusting POS. /SIZEClock Phase Clock PhaseMulti PIP 1366x768@60Hz RGB, DVI, Hdmi Advanced PIPOne screen Advanced PIP Press to exit from Options menu Sub screen Main screenCinema Picture AdjustmentsStandard DynamicAdvanced Settings Mute Sound AdjustmentSelect the magnification required for the enlarged display Digital ZoomDisplay the operation guide PositionButton Forward Present Time SetupPresent Time Setup Press to set up DAY or Present Time of DAYSET UP Timer Display the SET UP Timer Screen Press to selectPower on Time / Power OFF Time Negative / Scroll selection Mode selectionStart setting Screensaver For preventing image retentionReduces screen image retention Setup of Screensaver TimeSide BAR Adjust OFF Dark MID BrightPress to exit from Screensaver Reduces power consumption Customizing the Input labelsAddition sign Selected Input Component RGB SET UP for Input SignalsComponent / RGB in Select 3D Y/C Filter For Ntsc AV imagesColor System / Panasonic Auto Pulldown / Video NRColor System FREQ. kHz / V-FREQ. Hz Setting RGB sync signalSync Refresh RateOptions Adjustments Off MENU&ENTER On Off Initial VOL Sets normal volume LevelVolume display can go up to 63 regardless of the settings Becomes the same as the Maximum VOL levelNormal Standby EnableInitial Power FunctionState regardless of the slot power setting Installation NormalizationRotate Off Does not rotate the image Weekly Command Timer Press to set each item Press to select a command numberPress to select Time / Command Time Set the time to execute a command programShipping condition Troubleshooting Symptoms ChecksPlasma Display panel RGB PC input signalsCommand list of Weekly Command Timer Specifications For the U.S.A For Canada Page Customer’s Record