Panasonic TH-42PR10UA One screen Advanced PIP Press to exit from Options menu

Page 21

Advanced PIP

1

2

3

4

Press to display the Setup menu.

Press to select “OSD Language”.

Press and hold until the Options menu is displayed. Press to select Advanced PIP.

5

Press to adjust the menu.

Off : Sets normal two screen display mode

(see page 20).

On : Sets Advanced PIP mode.

Options1/3

Weekly Command Timer

Onscreen display

 

On

 

 

 

Initial INPUT

 

Off

 

 

 

Initial VOL level

Off

0

 

 

 

Maximum VOL level

Off

0

 

 

 

INPUT lock

 

Off

 

 

 

Button lock

 

Off

 

 

 

Remocon User level

 

Off

 

 

 

Advanced PIP

 

Off

 

One screen

Advanced PIP

 

6

Press to exit from

 

 

 

 

Options menu.

1

2

3

(When Advanced PIP is On)

Sub screen

Main screen

 

 

 

 

 

7

Press repeatedly.

 

 

 

 

Each time pressing this

6

5

4

button main picture and sub picture will be displayed as above.

Note:

Notes: To use , , , buttons for the screen operations, follow the procedures in the previous page.

• Advanced PIP corresponding signal

Sub screen

Main screen

NTSC, PAL, SECAM (tuner, video)

640x480@60Hz, 852x480@60Hz, 1024x768@60Hz,

525i, 525p, 625i, 625p, 750/60p, 750/50p, 1125/60i, 1125/50i,

1366x768@60Hz (RGB, DVI, HDMI)

1250/50i (Component Video, RGB, DVI, SDI, HDMI)

1280x768@60Hz (DVI)

If “INPUT lock” in Options menu is set to other than “Off”, MULTI PIP function isn’t available.

Sound output is from the picture which is selected in AUDIO OUT (PIP) (see page 24).

In 2 screen display, the same input mode cannot be selected for the main picture and sub picture.

The main picture and sub picture are processed by different circuits, resulting in a slight difference in the clarity of the pictures. There may also be a difference in the picture quality of the sub picture depending on the type of signals displayed on the main picture and depending on the 2-picture display mode.

Due to the small dimensions of the sub pictures, these sub pictures cannot be shown in detail.

Computer screen picture is displayed in a simplified format, and it may not be possible to discern details on them satisfactorily.

Following combinations of two analog signals cannot be displayed simultaneously;

Component - Component, Component - PC (RGB), PC (RGB) - Component, PC (RGB) - PC (RGB)

Refer to each board’s operating instruction for DVI, SDI, HDMI’s corresponding signals.

21

Image 21
Contents Operating Instructions Manual de instrucciones English EspañolModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents FCC Caution Canadian NoticeTrademark Credits When using the Plasma Display Safety PrecautionsSetup MaintenanceAC Power Supply Cord If problems occur during useAccessories Accessories SuppliedCheck that you have the Accessories and items shown AC cord connection see ConnectionsAC cord fixing Optional Terminal Board Insert Slot coveredPC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorSerial Terminals connection CommandCommunication parameters Basic format for control dataPower on / OFF Connecting the AC cord plug to the Plasma DisplayConnecting the plug to the Wall Outlet Initial selections Selecting the input signalSelecting the On-Screen Menu Language INPUT1 INPUT2 INPUT3 PCOn OFF Basic ControlsVolume Adjustment Channel AdjustmentOFF Timer button Digital Zoom see Press to accessAdvanced Settings Picture Setup SoundOn-Screen Menu Displays On Time / Power OFF Time / Power OFF TimeNormal Zoom Full Aspect ControlsIs pressed During Multi PIP Operations Normal FullClock Phase Adjusting POS. /SIZEClock Phase RGB/PC in modeMulti PIP One screen Advanced PIP Press to exit from Options menu Advanced PIPSub screen Main screen 1366x768@60Hz RGB, DVI, HdmiStandard Picture AdjustmentsDynamic CinemaAdvanced Settings Mute Sound AdjustmentDisplay the operation guide Digital ZoomPosition Select the magnification required for the enlarged displayPresent Time Setup Present Time SetupPress to set up DAY or Present Time of DAY Button ForwardSET UP Timer Display the SET UP Timer Screen Press to selectPower on Time / Power OFF Time Start setting Mode selectionScreensaver For preventing image retention Negative / Scroll selectionReduces screen image retention Setup of Screensaver TimeSide BAR Adjust OFF Dark MID BrightPress to exit from Screensaver Reduces power consumption Customizing the Input labelsAddition sign Selected Input Component / RGB in Select SET UP for Input Signals3D Y/C Filter For Ntsc AV images Component RGBColor System / Panasonic Auto Pulldown / Video NRColor System Sync Setting RGB sync signalRefresh Rate FREQ. kHz / V-FREQ. HzOptions Adjustments Volume display can go up to 63 regardless of the settings Off Initial VOL Sets normal volume LevelBecomes the same as the Maximum VOL level Off MENU&ENTER OnInitial Power EnableFunction Normal StandbyState regardless of the slot power setting Installation NormalizationRotate Off Does not rotate the image Weekly Command Timer Press to select Time / Command Press to select a command numberTime Set the time to execute a command program Press to set each itemShipping condition Troubleshooting Symptoms ChecksPlasma Display panel RGB PC input signalsCommand list of Weekly Command Timer Specifications For the U.S.A For Canada Page Customer’s Record