Panasonic TH-42PR10UA Reduces power consumption, Customizing the Input labels

Page 31

Reduces power consumption

• POWER SAVE:

When this function is turned ON, luminous level of the Plasma Display is suppressed, so

 

power consumption is reduced.

• STANDBY SAVE:

When this function is turned ON, power consumption of the microcomputer is reduced during

 

power supply standby (see page 12, 14-15), so standby power of the set is reduced.

• POWER MANAGEMENT:

The unit power supply is turned ON or OFF depending on whether or not there is a signal

 

during PC input mode.

 

This function is enabled when it is turned ON. (Only during input from PC (Mini D-sub)

 

terminal)

• AUTO POWER OFF:

Equipment power supply is turned OFF when there is no signal.

 

When this is set to On, the power supply of the unit goes Off 10 minutes after the input

 

signals stop.

 

This function is effective for input signals except input from PC (Mini D-sub) terminal.

1

2

Press to select

“POWER SAVE”

“STANDBY SAVE” “POWER MANAGEMENT” “AUTO POWER OFF”.

Press to select “ON” or “OFF”.

ON OFF

SET UP

1/2

SIGNAL

 

COMPONENT/RGB-IN SELECT

 

RGB

INPUT LABEL

PC

POWER SAVE

OFF

STANDBY SAVE

OFF

POWER MANAGEMENT

OFF

AUTO POWER OFF

OFF

OSD LANGUAGE

ENGLISH (US)

3

Note:

“POWER MANAGEMENT” and “AUTO POWER OFF” are Press to exit from SET UP. effective during normal viewing (one picture screen) only.

Customizing the Input labels

This function can change the label of the Input signal to be displayed.

Select the input signal which you would like to change its label before customizing the Input labels. (see page 13, 15)

Press to select INPUT LABEL.

Press to change the INPUT LABEL.

SET UP

1/2

SIGNAL

 

COMPONENT/RGB-IN SELECT

INPUT LABEL

RGB

PC

POWER SAVE

OFF

STANDBY SAVE

OFF

POWER MANAGEMENT

OFF

AUTO POWER OFF

OFF

OSD LANGUAGE

ENGLISH (US)

Note:

While selecting an Input signal through Optional Terminal Board connected to Slot1, Slot2 and Slot3, the Input label will depend on each Optional Terminal Board.

INPUT LABELS for Slot1, Slot2, Slot3 and Mini D-sub:

[Slot1 Input] INPUT1/VIDEO1/COMPONENT1/RGB1/DIGITAL1/PC1/DVD1/CATV1/VCR1/STB1

[Slot2 Input] INPUT2/VIDEO2/COMPONENT2/RGB2/DIGITAL2/PC2/DVD2/CATV2/VCR2/STB2

[Slot3 Input] INPUT3/VIDEO3/COMPONENT3/RGB3/PC3/DVD3/CATV3/VCR3/STB3 [PC (Mini D-sub) input] PC/COMPONENT/RGB/DVD/STB

When BNC Dual Video Terminal Board (TY-FB9BD) is used, an “A” or “B” is added at the end of each input label, depending on the input selected (see below).

Addition sign

“A”

“B”

Selected Input

Composite

S VIDEO

 

 

 

31

Image 31
Contents English Español Operating Instructions Manual de instruccionesModel No. Número de modelo Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents Canadian Notice FCC CautionTrademark Credits When using the Plasma Display Safety PrecautionsIf problems occur during use MaintenanceSetup AC Power Supply CordAccessories Supplied AccessoriesCheck that you have the Accessories and items shown Optional Terminal Board Insert Slot covered ConnectionsAC cord connection see AC cord fixingPC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorBasic format for control data CommandSerial Terminals connection Communication parametersConnecting the AC cord plug to the Plasma Display Power on / OFFConnecting the plug to the Wall Outlet INPUT1 INPUT2 INPUT3 PC Selecting the input signalInitial selections Selecting the On-Screen Menu LanguageOn OFF Basic ControlsDigital Zoom see Press to access Channel AdjustmentVolume Adjustment OFF Timer buttonPicture Setup Sound Advanced SettingsOn-Screen Menu Displays On Time / Power OFF Time / Power OFF TimeNormal Full Aspect ControlsNormal Zoom Full Is pressed During Multi PIP OperationsRGB/PC in mode Adjusting POS. /SIZEClock Phase Clock PhaseMulti PIP 1366x768@60Hz RGB, DVI, Hdmi Advanced PIPOne screen Advanced PIP Press to exit from Options menu Sub screen Main screenCinema Picture AdjustmentsStandard DynamicAdvanced Settings Mute Sound AdjustmentSelect the magnification required for the enlarged display Digital ZoomDisplay the operation guide PositionButton Forward Present Time SetupPresent Time Setup Press to set up DAY or Present Time of DAYDisplay the SET UP Timer Screen Press to select SET UP TimerPower on Time / Power OFF Time Negative / Scroll selection Mode selectionStart setting Screensaver For preventing image retentionReduces screen image retention Setup of Screensaver TimeOFF Dark MID Bright Side BAR AdjustPress to exit from Screensaver Customizing the Input labels Reduces power consumptionAddition sign Selected Input Component RGB SET UP for Input SignalsComponent / RGB in Select 3D Y/C Filter For Ntsc AV imagesPulldown / Video NR Color System / Panasonic AutoColor System FREQ. kHz / V-FREQ. Hz Setting RGB sync signalSync Refresh RateOptions Adjustments Off MENU&ENTER On Off Initial VOL Sets normal volume LevelVolume display can go up to 63 regardless of the settings Becomes the same as the Maximum VOL levelNormal Standby EnableInitial Power FunctionNormalization State regardless of the slot power setting InstallationRotate Off Does not rotate the image Weekly Command Timer Press to set each item Press to select a command numberPress to select Time / Command Time Set the time to execute a command programShipping condition Symptoms Checks TroubleshootingPlasma Display panel RGB PC input signalsCommand list of Weekly Command Timer Specifications For the U.S.A For Canada Page Customer’s Record