LC-52LE920UN/LC-60LE920UN
iv)Peel the protective sheet of the OCA.
Lift the ITO section, then peel the protective sheet by about half by means of the pull tap.
*Peeling it completely reduces workability. Check the order due to workability.
v)Contact the FPCB and joint end of the transparent electrode film with the glass.
*Grasp the opposite end. Note that the ITO is positioned by adhering.
*Note: Do not bend the PWB (FPCB section) and sheet (ITO section).
vi) Adhere the transparent electrode completely.
lPull tap for peeling the front protective sheet I
Peel the front protective sheet.
If bubbles are found, press those portions with glass cleaning cloth, etc. to remove them as much as possible.
Use a rubber roller since pressure exerted by it removes bubbles easily. See photo below.
For the TOUCH SENSOR Unit positioning figure, see page