JVC HR-A34U, HR-A54U instruction manual Access Main Menu Screen, Mode, Superimpose

Page 18

18EN

PLAYBACKANDRECORDINGFEATURES(cont.)

Superimpose

MENU

CH

OK

 

1

 

1

2

3

 

 

4

5

6

2

 

 

SD

7

8

9

 

 

 

 

 

 

 

0

4

 

MENU

3

OK

To recall an indication

1Press OSD.

All indications corresponding to the current status are displayed for 5 seconds. After that, the counter information and RECORD/PAUSE if in the Record Pause mode, are left displayed on the screen.

2Press OSD again to clear the display.

This function, switchable between ON and OFF, determines whether or not operational indicators will appear on screen.

 

 

 

ACCESS MAIN MENU

 

 

 

1

 

SCREEN

 

 

 

 

 

 

 

Press MENU.

 

 

 

 

 

 

 

 

ACCESS FUNCTION SET

 

 

 

2

 

SCREEN

 

 

 

 

 

 

 

Move the highlight bar (arrow) to "FUNCTION SET" by

 

 

pressing CHor , then press OK or%.

 

 

 

 

 

SELECT SUPERIMPOSE SET

 

3

 

MODE

 

 

 

 

 

 

 

 

HR-A34U

 

 

HR-A54U

 

 

 

 

 

FUNCTION

 

 

FUNCTION

 

 

 

 

 

AUTO TIMER

OFF

AUTO TIMER

OFF

 

 

 

 

=SUPERIMPOSE

ON

 

=SUPERIMPOSE

ON

 

 

 

 

 

AUTO SP=EP TIMER

OFF

 

AUTO SP=EP TIMER

OFF

 

 

 

 

 

VIDEO STABILIZER

OFF

VIDEO STABILIZER

OFF

 

 

 

 

AUTO PICTURE

ON

NEXT PAGE

 

 

 

 

 

 

SELECT WITH (5,°) AND (OK)

SELECT WITH (5,°) AND (OK)

 

 

 

 

PRESS (MENU) TO END

 

 

PRESS (MENU) TO END

 

 

 

 

 

Move the highlight bar (arrow) to "SUPERIMPOSE" by

 

 

 

pressing CHor , then press OK or%to select

 

 

the desired mode:

 

 

 

 

 

 

 

a– Select "ON" if you want the superimposed opera-

 

 

 

 

tional indications on the TV screen.

 

 

 

 

b– Select "OFF" if you do not want the superimposed

 

 

 

 

operational indications on the screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN TO NORMAL

 

 

 

4

 

SCREEN

 

 

 

 

 

 

 

Press MENU.

 

 

 

 

 

NOTES:

If you engage the Record Pause mode, RECORD/PAUSE is displayed regardless of the Superimpose mode setting.

If you select a channel on which no signal is received, the channel number is displayed regardless of the Superimpose mode setting.

The superimposed indication on the TV screen tells you what the VCR is doing.

Tuned-in channel or AUX(iliary) mode

 

 

 

 

 

 

 

 

When the channel is changed, the new

 

 

 

 

 

 

 

 

channel is displayed on the screen for 5

CH

125

 

RECORD

seconds.

THU 12:00 AM

 

PAUSE

Clock time

STEREO

 

] SP

SAP

 

 

 

 

 

 

 

Stereo program indication

B

+

+

+

 

 

 

E

 

(HR-A54U only)

 

 

 

INDEX-1

Second Audio Program indication

NORM

 

(HR-A54U only)

 

 

 

 

 

 

HI–FI

 

COUNT

–1:23:45

Tape position indicator

 

 

 

 

 

 

 

 

Audio mode indications (HR-A54U only)

Counter

 

reading

 

Operation mode

When the operation mode is changed, the new mode is displayed — RECORD (5 sec.), PLAY (5 sec.), FF/REW (5 sec. when engaged from Stop mode), RECORD PAUSE (for as long as Pause is engaged), and ITR *:** (5 sec.).

Tape speed indication

"Cassette Loaded" mark

When a cassette is loaded, the mark is displayed for 5 seconds. It blinks when the VCR's EJECT button is pushed.

INDEX indication

Image 18
Contents HR-A54U HR-A34U Dear Customer Do not place the VCRPower Lines Power SourcesPower Cord Protection Grounding or PolarizationCleaning AccessoriesDamage Requiring Service Replacement PartsContents Back of VCR EN Installing Your NEW VCRBasic Connections Matching Transformer not suppliedSituate VCR Check ContentsConnect VCR to Power Source Connect VCR to TVLanguage Clock To Make CorrectionsOK or% Tuner Access Tuner SETEN Initial Settings SETADD or Skip Desired Access Main MenuAccess Manual Channel SET Screen ChannelFind Program Start Point Simple PlaybackLoad a Cassette Start PlaybackSimple Recording Playback Features RE-ENGAGE Automatic Tracking Engage Manual Tracking ModeAdjust Manual Tracking Manual TrackingLayback and Recording Features Video StabilizerReset Counter to Zero Start RepeatAccess Main Menu Screen ModeSuperimpose Select Audio Monitor Access Function SETSET Mode Select The Soundtrack HR-A54U OnlyOr %to set to on or Auto PicturePreparation OFFPlayback Tape in useSelect Channel for Viewing Recording FeaturesEngage TV Mode Display Elapsed Time on ScreenStereo And SAP Second Audio Program HR-A54U Only To Record SAP ProgramsVCR Plus+ Timer Programming HR-A54U Only EN Timer RecordingInput Receiving Channel Number Engage Timer Mode VCR Plus+ Setup HR-A54U Only Access Initial SET ScreenVCR Plus+ Guide Channel Matching Number Access Guide Channel SET ScreenInput Guide Channel Repeat steps 5 and 6 forExpress Timer Programming SET Program DateSET Channel Number To Timer-Record Weekly Or Daily Serials Press SP/EP to set the tape speedCancel or Revise a RE-ENGAGE TimerProgram Auto SP→EP Timer Auto TimerEngage ITR Mode SET Recording DurationPress REC on the front panel Edit To Another VCR SET RECORDER’S Input Mode Edit From a Camcorder Or Another VCRPlayer Troubleshooting Procedure pg Timer againRe-perform the VCR Plus+ setup OubleshootingCan the VCR indefinitely remain in the still mode? Noise bars appear during search. What’s the problem?Questions and Answer S E N Can the VCR indefinitely remain in the Record-Pause mode?Express Timer Programming List Of TermsIndex HR-A34U has only one Audio input connector HR-A34U has only one Audio output connectorInstalling Batteries How To UseOperating JVC TVs Specification S For Servicing Only in U.S.A 881-5923 954 415Little Falls Road Fairfield, NJ Warranty Only in U.S.A. E N Slater DriveHR-A54U/34U