7 | RECORDING | |
|
| |
1Preparation | Connect an alarm sensor to the rear panel’s alarm input terminal. |
7 RECORDING |
|
Sensor recording is executed only when the VCR is in the Stop mode (Stop or Timer Record Standby mode) and an alarm |
signal is input to the rear panel’s ALARM IN terminal. |
| Press the [OPERATE] button to turn the operating mode |
| on. |
| Setting the function menu switches for the Alarm |
2 | Record mode |
| Press the [MENU] button to display the main menu |
3screen on the monitor. | |
| Press the [SHIFT |
| press the [SET |
| [The function menu switch setting screen is |
4 | displayed. |
| Press the [SHIFT |
Alarm
Alarm
7
recording function
recording duration Buzzer Tape end mode
A LARM / SENSOR | REC MODE |
(ALARM REC) | ON |
(SENSOR REC) | OFF |
(TIMER ALARM) | ON |
(DURATION) | 180SEC |
(BUZZER) | OFF |
(TAPE END MODE) | STOP |
PRESS (SHIFT, SET) |
|
PRESS (MENU) TO | END |
Alarm/sensor recording | |
mode setting screen |
Perform the settings for sensor recording in the same way as for "Alarm Recording" on page 33. | |
The mechanism of the | |
day or more). | If alarm inputs are frequent, use the alarm recording function instead and carry out regular maintenance/ |
inspection and parts replacement. | |
Preparation | Connect an alarm sensor to the rear panel’s alarm input terminal. |
1 |
Press the [OPERATE] button to turn the operating mode |
on. |
A LARM / SENSOR REC MODE |
5recording mode setting screen. |
Select the item to be set with the [SHIFT |
the value with the [SET |
• Set <ALARM REC> to ON to activate the alarm |
recording function. The AL REC indication in the |
display lights. |
• Set the alarm recording duration. |
Set duration to 5 sec., 15 sec., 30 sec., 60 sec., |
120 sec., 180 sec., TAPE END or MANUAL (for as |
long as alarm signals are input). |
| Select the timelapse recording mode (L12H or L24H) |
| with the [TIME MODE] button on the front panel. |
| [The selected recording mode is shown on the VCR's |
8 | display and the |
| Follow the procedures for "Basic recording operations" |
9on page 27. | |
| When an alarm signal is input to the rear panel's |
| ALARM IN terminal, alarm recording is executed as |
0specified. |
Setting the function menu switches for the Sensor | |
2Record mode | |
| Press the [MENU] button to display the main menu |
3screen. | |
| Press the [SHIFT |
| and press the [SET |
| [ The function menu switch setting screen is |
4 | displayed. |
| Press the [SHIFT |
Sensor recording function
Sensor recording duration Buzzer Tape end mode
(ALARM REC) | OFF |
(SENSOR REC) | ON |
(TIMER ALARM) | ON |
(DURATION) | 180SEC |
(BUZZER) | OFF |
(TAPE END MODE) | STOP |
PRESS (SHIFT, SET) |
|
PRESS (MENU) TO | END |
Alarm/sensor recording | |
mode setting screen |
| * When the alarm recording time is set to MANUAL, | |
| the alarm cue signal (index code) will not be | |
| recorded correctly if alarm input lasts for less than | |
| 30 seconds. | |
| * When alarm recording duration is set with an | |
| external switcher, set the alarm recording duration | |
| to MANUAL. | |
| • To sound the buzzer during alarm recording, set | |
| <BUZZER> to ON. | |
| • Set the operation mode at tape end in the case when | |
| alarm recording is executed even once with the menu | |
| switch <TAPE END MODE> on the alarm/sensor | |
| recording mode setting screen. | |
| STOP | : The tape stops. |
| REW | : The tape is rewound to the beginning and |
|
| stops. |
| REPEAT : Recording continues from the beginning of | |
|
| the tape. |
6 | EJECT | : The tape is ejected. |
| After setting the function menu switches, press the | |
| [MENU] button twice. | |
| [The normal screen is restored. | |
| Check the time and data shown on the monitor's on- | |
| screen display. |
If the time and date are not shown on the monitor or if
you want to change the display position, use the
<POSITION> function menu switch.
| To stop alarm recording and clear the alarm indication, |
| press the [AL/PL RESET] button. |
| • When the AL indication is lit on the display (during |
| alarm recording), press the [AL/PL RESET] button to |
| stop alarm recording. Timelapse recording is resumed |
| and the AL indication goes out. If the alarm buzzer is |
| on, it stops as well. |
| • When the AL indication is blinking on the display, |
| press the [AL/PL RESET] button. The AL indication |
! | goes out. |
| When the AL indication goes out, press the [AL/PL |
| RESET] button again to reset the alarm input/power loss |
| data. |
| * There may be some picture distortion at the start or |
| end of an alarm recording. This is not a malfunction. |
5recording mode setting screen. |
Select the item to be set with the [SHIFT |
the value with the [SET |
•Set the <SENSOR REC> to ON to activate the sensor recording function. The SENSOR REC indication in the display lights.
•Set the sensor recording duration.
Set <DURATION> to 5 sec., 15 sec., 30 sec., 60 sec., 120 sec., 180 sec., TAPE END or MANUAL (for as long as alarm signals are input).
*The sensor recording time will be shorter than the specified value.
*When the sensor recording time is set to MANUAL, the alarm cue signal (index code) will not be recorded correctly if alarm input lasts for less than
30 seconds.
*When sensor recording duration is set with an external switcher, set the sensor recording duration to MANUAL.
•To sound the buzzer during sensor recording, set <BUZZER> to ON.
•Set the operation mode at tape end in the case when sensor recording is executed even once with the menu switch <TAPE END MODE> on the alarm/sensor recording mode setting screen.
STOP | : The tape stops. |
REW | : The tape is rewound to the beginning and |
| stops. |
REPEAT: Sensor recording continues from the | |
| beginning of the tape. |
EJECT | : The tape is ejected. |
6After completing function menu switch setting, press the | |
[MENU] button twice. | |
[ | The normal screen is restored. |
Check the time and data shown on the monitor's on- | |
screen display. |
If the time and date are not shown on the monitor or if you need to change the display position, use the
7<POSITION> function menu switch.
•When an alarm signal is input to the rear panel's ALARM IN terminal, recording starts automatically in the specified record mode and the AL indication is lit.
•After the specified recording duration expires, recording stops and the Stop mode is engaged.
*Because sensor recording starts from the Stop mode, it takes several seconds from the time an alarm input is received to the time recording actually
8starts.
To stop sensor recording and clear the AL indication, 9press the [AL/PL RESET] button.
To disable sensor recording, set menu switch <SENSOR REC> to OFF.
During playback, there may be some noise or picture distortion at the point where one sensor recording stops and another starts. This is not a malfunction.