JVC SR-L910EK appendix Repeat Recording, Series Recording, Connections, 1Operations

Page 19

7

RECORDING

 

7-6 Repeat Recording

When the tape reaches the end during recording, it is automatically rewound and recording starts again from the beginning.

7 RECORDING

7-7 Series Recording

The series recording function facilitates recording over much longer periods using several connected SR-L910E/EKs. As soon as the tape ends in one VCR, the next VCR in the series starts recording.

5 To execute repeat recording, set <TAPE END MODE>

on the VTR mode 1 setting screen to REPEAT.

VTR

MODE 1

(SHARPNESS)

NORMAL

Connections

5 Setting the function menu switch <TAPE END MODE>

on the alarm/sensor recording mode setting screen

• When the tape ends during recording in the case when

alarm or sensor recording is executed even once, the

tape stops or rewinds and stops at the beginning if this

menu switch set to “STOP” or “REW”,.

If this menu switch is set to "EJECT", the tape is

Auto recording check function

Tape end mode

(VIDEO MODE)

AUTO

(AUTO REC)

OFF

(REC CHECK)

AUTO

(TAPE END MODE)

REPEAT

(INDEX SEARCH)

OFF

(INDEX AL/SKIP)

ALARM

(TAPE END BUZZER)

OFF

(WARNING BUZZER)

OFF

PRESS (SHIFT, SET)

 

PRESS (MENU) TO END

 

Set to REPEAT

5

Connect the first VCR’s [SERIES/CLOCK OUT] terminal

 

to the second VCR’s [SERIES/CLOCK IN] terminal.

 

Connect the second VCR’s [SERIES/CLOCK OUT]

 

terminal to the third VCR’s [SERIES/CLOCK IN]

 

terminal. Repeat for all connected VCRs. Connect the

 

VCR’s [COM] terminals as well.

5

Connect a video camera and/or other source equipment

Rear panel

ejected. To continue repeat recording even when alarm/ sensor recording is executed, set this menu switch to “REPEAT” .

VTR mode 1 setting screen

*When repeat recording is performed, the previously- recorded alarm recording is erased.

to the first VCR’s video and audio input connectors.

Connect the first VCR’s video and audio output

connectors to the second VCR’s video and audio input

connectors. Connect the second VCR’s video and audio

output connectors to the third VCR’s video and audio

input connectors. Repeat for all connected VCRs.

Connect the last VCR’s video and audio output

connectors to the monitor’s video and audio input

connectors.

COM

SERIES/CLOCK

COM

SERIES/CLOCK COM

SERIES/CLOCK

 

IN OUT

 

IN OUT

IN OUT

First VCR

Second VCR

Third VCR

1Operations

Auto Recording Check function

Function menu switch <REC CHECK> set to AUTO

Video input signal

 

Audio input signal

 

 

Set the <TERMINAL SEL 1> function menu switch on the VTR mode 2 setting screen to “SERIES” (series

This function automatically checks recording quality at the beginning of the tape during repeat recording.

To activate the Auto Recording Check function, set the

Repeat recording

 

 

Beginning of

Recording

Normal

Recording

the tape

check

Rear

I N

panel

 

 

O U T

recording) for all connected VCRs.

<REC CHECK> function menu switch in the VTR mode 1

setting screen to AUTO.

Operation of the Auto Recording Check function

The recorded section at the beginning of the tape is

 

automatically played back in the Repeat Record mode

 

and the FM level recorded on the tape is checked. If

 

the level is satisfactory, recording continues.

If recording quality is deemed inferior, the heads are

 

Defective

 

 

 

 

 

 

Auto head

 

 

 

 

 

 

cleaning

 

 

 

 

 

 

Auto recording

Recording

Normal

Recording

check

 

for several

 

 

 

seconds

 

 

 

 

 

 

 

 

 

Defective

 

 

 

 

 

 

 

Auto head

 

Recording

 

 

 

 

 

cleaning

 

 

 

 

 

 

 

 

First VCR

I N

O U T

 

 

 

 

 

VTR MODE 2

 

 

 

 

 

(SUMMER TIME)

OFF

TERMINAL

 

(TERMINAL SEL 1)

SERIES

 

SEL 1

 

(TERMINAL SEL 2)

WARN

REC

 

 

 

 

(REC REMAIN))

OFF

 

 

 

 

 

 

 

(NOISELESS PLAY)

OFF

REMAIN

 

 

(CAMERA SW)

OFF

 

 

 

 

 

 

 

 

 

 

(CAM SW WIDTH)

5msec

 

 

 

 

 

PRESS (SHIFT, SET)

 

 

 

 

 

 

PRESS (MENU) TO

END

Set to

SERIES

VTR mode-2 setting screen

cleaned automatically. After several seconds, recording

is checked again.

If recording quality is still unsatisfactory after two

consecutive checks, the error indicator E-09 is shown

in the display and recording continues.

Display

Error indicator E-09 display

Second VCR

 

 

I N

 

O U T

Last VCR

 

Video output

Audio output

 

 

• Output a series recording signal from the [SERIES/

 

CLOCK OUT] terminal to start recording. Select the

 

timing with the <REC REMAIN> function menu switch.

 

• When set to “OFF”, the series recording signal is

 

output when the tape ends.

 

• When set to “180S”, the series recording signal is

 

output about 3 minutes before the tape ends.

 

• When set to “360S”, the series recording signal is

2

output about 6 minutes before the tape ends.

 

To end function setting, press the MENU button to close

3the menu display and restore the time/date display.

 

Load cassettes with safety tab in place in all connected

4VCRs.

Monitor TV

Note

Engage the Record mode on the first VCR. Turn on all connected VCRs and put them in the Standby mode. This allows you to check picture and sound on the monitor. When the recording is complete on the first VCR, the second VCR automatically starts recording. This is repeated for all connected VCRs.

If a cassette has not been loaded in any VCR in the series, series recording will stop when that VCR is reached.

36

37

Image 19
Contents RS-232C Victor Company of JAPAN, LimitedLLT0014 LLT0014-001A-HDanish Safety Precautions Operation LockFor Your Safety Australia Connection to the mains supplyContents Introduction Major FeaturesPeriodical Maintenance IntroductionFront Panel Controls and ConnectorsRear Panel Mark in the Rec/Pause mode is shown in redSeries recording signal output Clock reset signal outputConnections Connecting to a CameraConnecting the Rear Panel Input/Output Terminal Connections Connecting a System Using a Sequential SwitcherMain Menu Display Monitor ON-SCREEN DisplayOn-Screen Display in the Time/Date and Record Modes Monitor ON-SCREEN Display1Operation Function Menu Switch SettingHour Meter Display PreparationScreens Items Contents of the Function Menu SwitchesScreens Items Set values Loading Date and Time SettingPreparation Cassette Loading/UnloadingPreparation Selection of Record/Play ModeSummer Time Compensation Recording RecordingPreparation RecordingSetting the daily timer Timer Recording1Changing a preset timer program Setting the weekly timerAlarm input during timer recording Canceling timer programmingRecording Alarm signal input Alarm RecordingTimelapse Alarm Alarm Timelapse RecordingSensor Recording 1Operations Repeat RecordingSeries Recording ConnectionsTape End Buzzer Recording with External VCR Activation SignalExternal Timer Recording How to Restore Recording After Power FailurePlayback Playback and SPECIAL-EFFECTS PlaybackSpecial-Effects Playback When the picture moves up and down in the Still mode TroubleshootingTracking/V. Lock Adjustment Contents VCR operation MeasuresNo Error Indication TroubleshootingRS-232C protocol SA-K97U SpecificationsPin connector specifications Data formatVCR setting commands SA-K97U RS-232C Protocol & CommandsCommand description VCR control commands5th byte Commands for VCR status verification4th byte 6th byte Contents of 5th byte BIT 0/1/2/3 Speed Code Commands reference chart4th byte Appendixes SpecificationsCAM SW OUT camera switching signal output Other input/output terminal signal levels