ON-SCREEN DISPLAY – Alarm display –
Alarm display : Alarm messages are displayed as shown below, when an operation error has occurred or when the unit is in a poor condition for operation. E.g., dirty head.
| 3 2 K | C H – 1 / | 2 |
|
| S P | 0 0 0 m i n | ||
A |
| H E A D | C L E A N I | N G |
| R E Q U I | R E D ! | ||
|
| ||||||||
B |
|
|
| N O | D V | S | I | G N A L |
|
| 0 4 | / 0 1 | / 0 2 |
|
|
| S T A N D B Y - O F | ||
| F 1 1 | : 2 0 | : 0 0 |
| T C R | 0 2 : 0 0 : 0 0 : 0 |
Display at position A : Displays which show the state of the unit (and which are not set
via the DISPLAY mode) continues to be displayed here until the conditions are rectified.
Display COPY INHIBIT REC INHIBIT
A. DUB INHIBIT (REC TAB)
A. DUB INHIBIT (48K)
A. DUB INHIBIT (LP)
A. DUB INHIBIT (BLANK)
A. DUB INHIBIT (DV)
Contents The user attempts to record signals protected with the copy guard.
The user attempts to record on a write protected cassette tape. (The rear slide is pushed to SAVE.)
The user attempts to perform audio dubbing on a write protected cassette tape. (The rear slide is pushed to SAVE.)
This message is displayed when audio dubbing is attempted under the following con- ditions:
•The AUDIO MODE item of the AUDIO/VIDEO menu is set to 48k.
•The tape is recorded with a sample frequency of 48kHz.
The user attempts to perform audio dubbing on a tape recorded in the LP mode.
The user attempts to perform audio dubbing on a blank tape.
The user attempts to perform audio dubbing during DV signal input. (The INPUT SEL switch is set to DV)
Display LOW VOLTAGE
HEAD CLEANING REQUIRED!
OVERHEATING!
Contents
The voltage of the DC input power is low. Continued operation will bring the unit to the Operate OFF mode.
The video head is dirty. Please clean it with the dedicated
The temperature inside the unit has exceeded the regulated value. Please disconnect the power and place the unit in a cool place. If this message is displayed again, dam- age may have occurred. Please consult with your
A. DUB INHIBIT (NTSC/PAL)
A. DUB INHIBIT (DVCAM)
OPERATION LOCK
This message is displayed when the signal system is changed during audio dubbing (NTSC or PAL).
The user attempts to perform audio dubbing on a DVCAM format tape.
This message is displayed when a button on the unit is pressed while the OPERA- TION LOCK function is engaged (ie, the OPERATION item of the SYSTEM (2/2) menu is set as ON).
Warning display : When anomalies occur in the VTR, warning messages with error codes will be displayed.
Display at position B : Messages indicating operation errors are displayed for about 3 seconds.
They are displayed when the DISPLAY mode is ON or AUTO.
3 2 K | C H – 1 | / 2 | S P 0 0 0 m i n |
Display INVALID TAPE!
LP TAPE!
NO DV SIGNAL
Contents
Data tapes for PC use or DVC PRO tapes has been inserted. The cassette will be ejected.
The user attempts to play back a tape recorded in the LP mode. This unit cannot record or play in the LP mode.
The user attempts to record without DV signal input.
|
| W |
| D R U M | |
0 4 | / 0 1 | / 0 2 |
1 1 | : 2 0 | : 0 0 |
A R N I N G M O T O R
T C R
7 0 0 | 1 |
F A I | L U R E |
S T A N D B Y | |
0 2 : | 0 0 : 0 |
| Warning display |
| For details, please |
| refer to page 66, |
| “Warning Display”. |
- O F F | |
0 | : 0 0 |
For servicing
→The possibility of FAN motor failure
→ | For servicing | |
Refer to the servicemanual page. | ||
|
22
23