Extron electronic IN1403 manual Troubleshooting, Problem There is no image on the display device

Page 26

Troubleshooting

Problem: There is no image on the display device.

Solution 1: Make sure that the power cable is securely plugged into the unit and the A/C source.

Solution 2: Make sure the A/C source is live.

Solution 3: Verify that the power switch is turned on for the video source, the IN1403, and the monitor.

Solution 4: Verify the connection to the output display device. Even with no input signal, the IN1403 menu can be displayed. Press MENU or ENTER to gain access to the menu screen.

Solution 5: Select an output resolution and refresh rate compatible with the display device being used. Use the default power-up buttons to select an output mode without the menu present, and then turn on the blue screen to verify these settings.

Solution 6: The output resolution must be less that the input (the IN1403 can only scale up). Select an output resolution that is greater than or equal to the input size.

Solution 7: The display device may not accept certain sync formats. Verify the display device sync capability and select the IN1403 output sync using the power-up default buttons.

Problem: There is no audio output.

Solution 1: Verify that power is present and that the power switch is turned on for the audio source, the IN1403, and the amplifier/speakers.

Solution 2: Verify that the audio source is connected to the correct input and that the source volume has not been turned down or muted.

Solution 3: The audio output of the IN1403 is line level audio only. It should be connected to a mixer/amplifier or to amplified “computer type” speakers.

Solution 4: Increase the volume using the volume UP button.

Solution 5: The mute may be activated. Press MUTE to deactivate the function.

Problem: The image on the display device is scrambled.

Solution: Select an output resolution and refresh rate compatible with the display device being used. Use the default power-up buttons to select an output mode without the menu present, and then turn on the blue screen to verify these settings.

Problem: The image on the display device is cropped on the left side.

Solution 1: Increase the output H-Position to line up the image on the display device. Use the blue screen.

Solution 2: Adjust the monitor position or size controls to fit the image on the display device. Use the blue screen.

24

IN1403 User’s Manual

Image 26
Contents IN1403 Precautions Table of Contents Description FeaturesProduct Overview Output CompatibilityInput Installation Front Panel Controls IN1403 application diagramOperation On-screen menu IN1403 on-screen display menu system Press Enter Menu CommandsVideo Menu Range Factory default setting Operation Range 6 to Factory Default Setting 16 0.0dB Operation Audio menuInput menu Example IN1403 User’s Manual Output menu Advanced menuChoosing the Optimal Output Resolution and Refresh Rate CRT displays Selecting the golden resolutionCRT displays Selecting the optimal refresh rate Projectors, Flat Panel and Plasma Display Devices Pass-through RGB video Output RGB connectorsAdvanced Operation Output modesOutput positioning Power-on settingsRemote Operation RS-232 controlBaud Rate and Protocol Command Code Structure and DelimitersSample command codes Baud Rate SelectionIN1403 serial commands Command DescriptionBRG? REF2 Problem There is no audio output TroubleshootingProblem There is no image on the display device Problem The image on the display device is scrambledProblem The image on the display device is the wrong shape Problem The display device has a double imageProblem The image is frozen Problem The image on the display device appears fuzzySpecifications Included Parts Part Numbers Optional Accessories Part NumbersPart Numbers IN1403 User’s Manual Extron’s Warranty Asia JapanExtron Electronics, USA