Extron electronic IN1403 manual Range Factory default setting Operation

Page 11

Hue (NTSC signals only) adjusts the picture’s color towards red or green.

Range:

0 to 40

Factory default setting: 20

Operation:

Press

button to increase the green.

Press ￿button to increase the red.

Sharpness uses variable filtering to affect input picture detail and definition.

Increasing the sharpness setting gives the visual effect that the noise filter setting is decreasing. Although the sharpness and noise filter settings seem to offset each other, they are actually two different adjustments that affect two different sets of circuitry. Operators should adjust both settings until optimal picture quality is achieved.

Range:

0 to 7

Factory default setting: 3

Operation:

Press

button to increase the sharpness.

Press ￿button to decrease the sharpness.

If the following settings seem confusing, we recommend that you experiment with the MENU, , , , and ENTER buttons until you familiarize yourself with the IN1403 front panel control

1.

Set the brightness￿￿￿and contrast controls to factory default positions.

￿

2.

Adjust Gamma as desired.

 

 

Range:

1 to 30

 

 

Factory default setting: 10*

 

 

Operation:

 

 

Press

button to step to higher numbered gamma curves.

 

operations. It’s a good idea to get comfortable using these buttons to navigate through the on- screen menu system before moving on to other sections of this manual. If you get lost, enter unfamiliar territory or are afraid of making an improper selection, press the MENU button to safely leave the menu system without making any changes. We also recommend that, unless you’re a qualified audiovisual technician, you avoid the Advanced menu.

Gamma: The 30 active gamma correction curves programmed into the IN1403 are used to compensate for the non-linear response of many display devices. Since Gamma, Brightness and Contrast controls interact with each other, the following order of adjustments is suggested:

Press ￿button to step to lower numbered gamma curves.

* The factory default setting of 10 refers to a gamma correction curve of 1.0.

3.Adjust brightness and contrast to fine tune the image (see page 8 for procedures).

Noise Filter changes the input signal noise filter.

Increasing the noise filter setting makes the picture sharpness appear to decrease. Refer to the Sharpness section at the top of the page.

Range:

0 to 47

Factory default setting: 5

Operation:

Press

button to increase noise filter.

Press ￿button to decrease noise filter.

IN1403 User’s Manual

9

Image 11
Contents IN1403 Precautions Table of Contents Description FeaturesProduct Overview Output CompatibilityInput Installation Front Panel Controls IN1403 application diagramOperation On-screen menu IN1403 on-screen display menu system Press Enter Menu CommandsVideo Menu Range Factory default setting Operation Audio menu Range 6 to Factory Default Setting 16 0.0dB OperationInput menu Example IN1403 User’s Manual Advanced menu Output menuCRT displays Selecting the golden resolution Choosing the Optimal Output Resolution and Refresh RateCRT displays Selecting the optimal refresh rate Projectors, Flat Panel and Plasma Display Devices Output modes Output RGB connectorsAdvanced Operation Pass-through RGB videoRS-232 control Power-on settingsRemote Operation Output positioningBaud Rate Selection Command Code Structure and DelimitersSample command codes Baud Rate and ProtocolCommand Description IN1403 serial commandsBRG? REF2 Problem The image on the display device is scrambled TroubleshootingProblem There is no image on the display device Problem There is no audio outputProblem The image on the display device appears fuzzy Problem The display device has a double imageProblem The image is frozen Problem The image on the display device is the wrong shapeSpecifications Included Parts Part Numbers Optional Accessories Part NumbersPart Numbers IN1403 User’s Manual Asia Japan Extron’s WarrantyExtron Electronics, USA