Adaption to a different type of gas supply
If you are using a different kind of gas from the one indicated on the serial no. plate and the orange label on the back of the hob, you must replace the injectors; in the case of the Wok burner, adjust the primary air (see Injector table on page 6).
The orange label should be removed and kept together with the manual.
Use pressure regulators suitable for the gas pressures indicated on page 6
•In order to replace the injectors, contact the Customer Care Centre on
•Injectors not supplied as standard should be
requested from the Customer Care Centre on
• Regulate the minimum levels of the taps.
Note: with liquid petroleum gas ( G30/G31) the bypass screw must be screwed in fully. If you then experiance difficulty in turning the control knob, contact our After sales Service though our Customer Care Centre on
Replacing the injectors
Note: Refer to the injector table to ensure the correct type of injector is to be fitted.
Traditional burners (T)
1.Remove the pan supports (A).
2.Remove the burners (B).
3.Unscrew the injector (C) with a no 7 box spanner.
4.Replace the injector with one suitable for the new gas type.
5.Replace burners and pan supports.
Note: Before installing the hob, please remember to stick the gas calibration label, provided with the replacement injectors over the gas information on the underside of the hob.
Wok Burner (W)
It is best to change the wok double crown burner before starting installation:
1.Lift out the hob from the work surface, removing the installation fixing pieces.
2.Remove the screws securing the glass, at the back of the hob plate and those located on both sides of the hob (E).
3.Remove the holding screws that fix the burner to the glass hob. Once you have removed the glass hob, you can access the wok burner injector.
4.Remove the injector (F) using a 10mm spanner.
5.Slacken the holding screw (H) to regulate the position (X) of the gas inlet coupling (G) with regard to the injector.
12