Kathrein 9986492, MSK 33 manual Radio Operation, Radio menu, Radio Analog menu

Page 53

Radio Operation

RADIO menu

Returns to TV menu.

Entering a frequency from 44.75

MHz to 867.20 MHz

The field lights up yellow as soon as the softkey is pressed. Now, the frequency can be entered in with the nu- merical buttons, „0...9,“ and the „MHz“ button or

changed with the cursor buttons, ◄►. The frequency is displayed on the screen in the lower left-hand corner.

RADIO CONTROL menu

In this menu, all remotely controlled parameters such as remote feed voltage, 22 kHz, DiSEqC, tone burst (Simple DiSEqC) and V-SEC can be set.

ANALOG menu

In this menu, min./max. level measurements are possible and the „level beep“ can be activated.

RADIO ANALOG menu

Level-dependant acoustic signal

In the function, „level beep,“ a acoustic signal is generated, whose pitch is proportional to the received signal level.

With this signal, it is possible to optimally align the receiving antenna to a transmit- ter.

Carrying out measurements

By pressing the button, the following value are measured:

- Minimal and maximal level (min/max)

Level measurement

The reception frequency can be changed by using the cursor buttons, ◄►.

53

Image 53
Contents Sat/TV/FM Test Receiver MSK Page Preface Contents Checking the LNB supply voltage of a satellite receiver Selecting the colour standards PAL, Secam and Ntsc Mpeg transport stream interface TS-Parallel, Lvds optional Measuring an audio signal via the AV socket Scart Measurement of analogue signals in Sat operation 100 113 107Explanation of symbols General safety informationImportant Notes Validity of this manualConnections Safety InstructionsProper use Mechanical loadbearing capacityFunctions FunctionsFunction Functions overviewReturn path LP DVB-S DVB-S/C/TFront panel Displays, Operating Elements and ConnectionsRear panel Mains connection Mains switch DC socket Option / XLR-socketHeadphone connection TS parallel Option 10 AUXSide view MSK Observing angle of the on screen displayFrequently recurring softkeys Operating ConceptScreen Menu selection General information for operationMain menu Accu CAP % I=0.00 aMains voltage / mains switch Place of installation of the MSKOn/Off switch Safety fuseDC socket option Accumulator and Battery OperationAccumulator operation Connections Maximal input level Measurement PossibilitiesLevel measurement Sat menu Sat OperationEntering the transponder frequency Setting of the LNB voltage supplySelecting the LO frequency Bargraph Level range Comment Display Switch-over of Analog digit. DvbsIII Calling up menu LNB-CONTROLLNB control menu KHz control signalLNB supply voltage LNB current drawDiSEqC Checking the LNB supply voltage of a satellite receiverCalling up the DiSEqC/V SEC menu DiSEqC menu TX display field Submenu for entering DiSEqC commandsDisplay field a Display field BData burst Tone burst Example Entering and transmitting a DiSEqC commandSimple DiSEqC General information UFOmicro DiSEqC menuDisplay fields RX 0 E2 101390 Tx+rx CommandOperating the menus ModusSat Operation Entering the hex numbers Sending a V-SEC command TXSEC menu Initial ANALOG-menu Level-dependent acoustic signalCalling up the sound subcarrier MenuVideo polarity Second Anlaog menuSetting of the de-emphasis Audio carrier settingSat subcarrier menu Audio carrier frequencyAudio carrier table for reception type Audio carrier tables for the satellite reception27.500 Digital MeasurementsSAT Digital menu Level measurement Digital Min./Max. levels TV menu TV OperationC10 210.25MHz A65.0dBµV Rf chanLNB U= 0.0 V I= 0 mA TV control menuTV-DiSEqC /VSEC menu Selecting the standard Analogue menuAudio carrier table for TV reception Selecting the audio carriersMeasuring the current level Measuring the min./max. levelSelecting the colour standards PAL, Secam and Ntsc Measuring audio carrier spacingSelecting demodulation for DVB-C measurement TV Digital menuMode 900 SR1ChBW 8MHz DVB-T optionalSelecting channel bandwidths Return path if menu Return Path if MenuAudio carrier table for if reception Analog menuMeasurement of the current level Measurement of the min./max. levelMeasurement of the audio carrier spacing If RP Digital Menu QAM64 modeEntering symbol rate Radio Analog menu Radio OperationRadio menu Measuring the min/max level FM Measure ALLDecoder operation AV MenuDecoder operation baseband Video input Video outputMpeg transport stream interface TS-Parallel, Lvds optional Breaking voltageRGB operation 3sat KiKa Phoenix Mpeg Decoder Menu OptionalPAT 08 Offset 0.0 dB Setting MenuUnit dBmV Screen Menu Screen setupSetting the time Click button Setting the dateSystem Menu Calls up the SYS TEM menuSaving the unit settings Saving and calling up unit settingsCalling up saved settings Copy MenuPrinting out all measurements in Sat mode Printing out all measurements in TV modeSpectr Mode MenuEnlarging the videotext Text MenuHolding the videotext Original videotext sizeHorizontal zoom -Enlarging the video signal Horizontal zoom Reducing the video signalScope Menu Video scope menuSelecting the video line Measurement of the amplitude of the video signalMeasurement of video signals via the AV socket Scart Pos Audio ScopeTime DiSEqC Scope Position and triggering of the DiSEqC signalSaving function Shot ContMarker Span Large ¡ mark ßlevel Spectral MenuAna MaxMarker Dig Marker AnaZoom marker Max off Measurement of digital signals in Sat operationCross-polarisation measurement on signals in SAT operation Measurement of the bit error rate BER Constellation diagram for Qpsk DVB-SConst Menu Colour representation of I/Q value pairsFrontend locked Measurement of signal noise ratio SNRCarrier offset Inverting /not inverting a constellation diagram Selecting the symbol rate symbol-clock27.500 SR Selecting the code rateExamples for Qpsk constellation diagrams Measurement of modulation error rate MER Constellation diagram for QAM DVB-CZoom Inverting /not inverting constellation diagramExamples for QAM constellation diagram Const Menu Measurement of bit error rate BER Constellation diagram DVB-T optionalMeasurement of signal noise ration SNR Carrier modeHierarchy Code rate Guard Invers Frontend locked Channel display Impulse response representation Echo representation optional Measuring principle Broadband Cable Analysis Measuring System MSKTrack MVG10 Downstream measurement Upstream measurementMSK33 MVG10 RGB MSK33Cable system With return path capable amplifiers Display of the check point Auto MeasureConnection cable for modem / RS InterfacesModem / RS 232 interface Setting local echo Setting baud rateSetting hardware handshake Modem/RS232 menuTTY mode Code PasswordAnsi mode Log-in procedureRequesting help Example for logging-in in Ansi modeInterfaces List of the command abbreviations STU Loading and saving predefined settingsSTU RET LDUMaintenance, Storage and Customer Service Ribbon exchange Printer paper-exchanging the ribbonBefore opening the unit, disconnect the supply voltage Command overview framing byte Overview of DiSEqC commandsCommand overview address byte Technical AppendixReset Reset DiSEqC minicontroller Command overview command byteCommand overview data byte DiSEqC commands for Kathrein matricesCommand for Kathrein matrix 9xx-series Command for Kathrein matrix EXRChannel and frequency table standard B/G frequency in MHz Channel tablesVHF-CCIR UHF-CCIR USB/OSB ESBVHF UHF Channel and frequency table standard Lfrequency in MHzVII Channel and frequency table standard D/K frequency in MHzViii XIIChannel and frequency table standard I frequency in MHz Channel and frequency table standard M/N frequency in MHz Channel and frequency table standard M/Nfrequency in MHz Power supply Technical DataTechnical data MER SNRQpsk BER Assignment of the Scart socket AccessoriesScope of delivery TXD RXD RTS CTS DSR GND DCD DTR Assignment of RS232 socketAssignment of socket TS Parallel optional Unit variants General notes Downloading New MSK33 Operating Software114 115