Printing the measurement results
By pressing the softkey, the current measurement result along with the date and time are printed out.
Printing out a measurement result in TV mode with:
-Date and time
-Channel number, frequency
-Analogue measurement (A), level.
If the function, „measure,“ is called up in the TV, Sat or FM menu, all the meas- urements are printed out.
Printing out all measurements in TV mode
The printout contains the following measurement results:
-Date and time
-Audio carrier spacing TT1: - 13 dB
-Audio carrier spacing TT2: not available
-Audio carrier spacing NICAM: - 20 dB
-Bit error rate NICAM: 8.20E
-Minimal level: 52.5 dBµV
-Maximal level: 59 dBµV
-Channel: 10
-Video carrier frequency: 210.25 MHz
-Analogue measurement: A
-Current level: 56 dBµV
Printing out all measurements in Sat mode
The printout contains the following measurement results:
-Minimal level: 67.5 dBµV
-Maximal level: 69 dBµV
-Transponder frequency: 11373,15 MHz
-Analogue measurement: A
-Current level: 68 dBµV