Copy Menu

Printing the measurement results

By pressing the softkey, the current measurement result along with the date and time are printed out.

Printing out a measurement result in TV mode with:

-Date and time

-Channel number, frequency

-Analogue measurement (A), level.

If the function, „measure,“ is called up in the TV, Sat or FM menu, all the meas- urements are printed out.

Printing out all measurements in TV mode

The printout contains the following measurement results:

-Date and time

-Audio carrier spacing TT1: - 13 dB

-Audio carrier spacing TT2: not available

-Audio carrier spacing NICAM: - 20 dB

-Bit error rate NICAM: 8.20E -06

-Minimal level: 52.5 dBµV

-Maximal level: 59 dBµV

-Channel: 10

-Video carrier frequency: 210.25 MHz

-Analogue measurement: A

-Current level: 56 dBµV

Printing out all measurements in Sat mode

The printout contains the following measurement results:

-Minimal level: 67.5 dBµV

-Maximal level: 69 dBµV

-Transponder frequency: 11373,15 MHz

-Analogue measurement: A

-Current level: 68 dBµV

Line feed

62

Image 62
Contents Sat/TV/FM Test Receiver MSK Page Preface Contents Checking the LNB supply voltage of a satellite receiver Selecting the colour standards PAL, Secam and Ntsc Mpeg transport stream interface TS-Parallel, Lvds optional Measuring an audio signal via the AV socket Scart Measurement of analogue signals in Sat operation 100 107 113Important Notes General safety informationExplanation of symbols Validity of this manualProper use Safety InstructionsConnections Mechanical loadbearing capacityFunctions FunctionsReturn path LP Functions overviewFunction DVB-S DVB-S/C/TDisplays, Operating Elements and Connections Front panelHeadphone connection Mains connection Mains switch DC socket Option / XLR-socketRear panel TS parallel Option 10 AUXObserving angle of the on screen display Side view MSKFrequently recurring softkeys Operating ConceptScreen Main menu General information for operationMenu selection Accu CAP % I=0.00 aOn/Off switch Place of installation of the MSKMains voltage / mains switch Safety fuseDC socket option Accumulator and Battery OperationAccumulator operation Connections Maximal input level Measurement PossibilitiesLevel measurement Sat Operation Sat menuEntering the transponder frequency Setting of the LNB voltage supplySelecting the LO frequency III Switch-over of Analog digit. DvbsBargraph Level range Comment Display Calling up menu LNB-CONTROLLNB supply voltage KHz control signalLNB control menu LNB current drawDiSEqC Checking the LNB supply voltage of a satellite receiverCalling up the DiSEqC/V SEC menu DiSEqC menu Display field a Submenu for entering DiSEqC commandsTX display field Display field BData burst Tone burst Example Entering and transmitting a DiSEqC commandSimple DiSEqC Display fields UFOmicro DiSEqC menuGeneral information RX 0 E2 10Operating the menus Tx+rx Command1390 ModusSat Operation Entering the hex numbers Sending a V-SEC command TXSEC menu Calling up the sound subcarrier Level-dependent acoustic signalInitial ANALOG-menu MenuSecond Anlaog menu Video polaritySat subcarrier menu Audio carrier settingSetting of the de-emphasis Audio carrier frequencyAudio carrier tables for the satellite reception Audio carrier table for reception type27.500 Digital MeasurementsSAT Digital menu Level measurement Digital Min./Max. levels C10 210.25MHz A65.0dBµV TV OperationTV menu Rf chanLNB U= 0.0 V I= 0 mA TV control menuTV-DiSEqC /VSEC menu Audio carrier table for TV reception Analogue menuSelecting the standard Selecting the audio carriersSelecting the colour standards PAL, Secam and Ntsc Measuring the min./max. levelMeasuring the current level Measuring audio carrier spacingMode TV Digital menuSelecting demodulation for DVB-C measurement 900 SR1ChBW 8MHz DVB-T optionalSelecting channel bandwidths Return Path if Menu Return path if menuAnalog menu Audio carrier table for if receptionMeasurement of the current level Measurement of the min./max. levelMeasurement of the audio carrier spacing If RP Digital Menu QAM64 modeEntering symbol rate Radio Analog menu Radio OperationRadio menu FM Measure ALL Measuring the min/max levelDecoder operation baseband Video input AV MenuDecoder operation Video outputMpeg transport stream interface TS-Parallel, Lvds optional Breaking voltageRGB operation 3sat KiKa Phoenix Mpeg Decoder Menu OptionalPAT 08 Offset 0.0 dB Setting MenuUnit dBmV Screen setup Screen MenuSystem Menu Setting the dateSetting the time Click button Calls up the SYS TEM menuCalling up saved settings Saving and calling up unit settingsSaving the unit settings Copy MenuPrinting out all measurements in TV mode Printing out all measurements in Sat modeMode Menu SpectrHolding the videotext Text MenuEnlarging the videotext Original videotext sizeScope Menu Horizontal zoom Reducing the video signalHorizontal zoom -Enlarging the video signal Video scope menuSelecting the video line Measurement of the amplitude of the video signalMeasurement of video signals via the AV socket Scart Pos Audio ScopeTime Saving function Position and triggering of the DiSEqC signalDiSEqC Scope Shot ContAna Spectral MenuMarker Span Large ¡ mark ßlevel MaxMarker Ana Marker DigZoom marker Max off Measurement of digital signals in Sat operationCross-polarisation measurement on signals in SAT operation Const Menu Constellation diagram for Qpsk DVB-SMeasurement of the bit error rate BER Colour representation of I/Q value pairsFrontend locked Measurement of signal noise ratio SNRCarrier offset 27.500 SR Selecting the symbol rate symbol-clockInverting /not inverting a constellation diagram Selecting the code rateExamples for Qpsk constellation diagrams Constellation diagram for QAM DVB-C Measurement of modulation error rate MERInverting /not inverting constellation diagram ZoomExamples for QAM constellation diagram Const Menu Measurement of signal noise ration SNR Constellation diagram DVB-T optionalMeasurement of bit error rate BER Carrier modeHierarchy Code rate Guard Invers Frontend locked Channel display Impulse response representation Echo representation optional Broadband Cable Analysis Measuring System MSK Measuring principleTrack MVG10 MSK33 MVG10 Upstream measurementDownstream measurement RGB MSK33Cable system With return path capable amplifiers Auto Measure Display of the check pointConnection cable for modem / RS InterfacesModem / RS 232 interface Setting hardware handshake Setting baud rateSetting local echo Modem/RS232 menuAnsi mode Code PasswordTTY mode Log-in procedureExample for logging-in in Ansi mode Requesting helpInterfaces List of the command abbreviations STU RET Loading and saving predefined settingsSTU LDUMaintenance, Storage and Customer Service Ribbon exchange Printer paper-exchanging the ribbonBefore opening the unit, disconnect the supply voltage Command overview address byte Overview of DiSEqC commandsCommand overview framing byte Technical AppendixCommand overview command byte Reset Reset DiSEqC minicontrollerCommand for Kathrein matrix 9xx-series DiSEqC commands for Kathrein matricesCommand overview data byte Command for Kathrein matrix EXRVHF-CCIR UHF-CCIR Channel tablesChannel and frequency table standard B/G frequency in MHz USB/OSB ESBChannel and frequency table standard Lfrequency in MHz VHF UHFViii Channel and frequency table standard D/K frequency in MHzVII XIIChannel and frequency table standard I frequency in MHz Channel and frequency table standard M/N frequency in MHz Channel and frequency table standard M/Nfrequency in MHz Power supply Technical DataTechnical data MER SNRQpsk BER Assignment of the Scart socket AccessoriesScope of delivery Assignment of RS232 socket TXD RXD RTS CTS DSR GND DCD DTRAssignment of socket TS Parallel optional Unit variants Downloading New MSK33 Operating Software General notes114 115