Dell UCPM-800 manual Physical Disk Roaming, Background Initialization Of Virtual Disks

Page 13

Background Initialization Of Virtual Disks

Both Consistency Check (CC) and Background Initialization (BGI) correct parity errors. However, CC reports data inconsistencies through an event notification, whereas BGI is an automatic process.

BGI does not run on RAID 0 virtual disks. You cannot disable BGI permanently. If you cancel BGI, it automatically restarts within five minutes. Unlike full or fast initialization of virtual disks, BGI does not clear data from the physical disks. CC or BGI typically causes some loss in performance until the operation completes.

NOTE: In systems with Fault Tolerant Shared PERC 8 card configuration, in the event of controller failover, a BGI starts automatically on each virtual disk. If a BGI operation was in progress at the time of controller failover, then the BGI resumes on the new active Shared PERC 8 controller from the last recorded checkpoint.

Full Initialization Of Virtual Disks

CAUTION: Performing a full initialization on a virtual disk overwrites all blocks and destroys any data that previously existed on the virtual disk. Full initialization of a virtual disk eliminates the need for the virtual disk to undergo a BGI. Full initialization can be performed after the creation of a virtual disk.

During full initialization, the host is not able to access the virtual disk. You can start a full initialization on a virtual disk in the CMC.

In the event of a controller failover in systems with Fault Tolerant Shared PERC 8 card configuration, full initialization does not continue on the active controller. You must start full initialization again through CMC. For more information on virtual disk initialization, see the Dell Chassis Management Controller for Dell PowerEdge VRTX User’s Guide at dell.com/poweredgemanuals and the Dell Chassis Management Controller for Dell PowerEdge VRTX Online Help.

In the event of controller failover or system reboot during a full initialization, the operation terminates and a BGI begins on the virtual disk.

NOTE: Performing a full initialization prevents a BGI from starting automatically on virtual disks.

Fast Initialization Of Virtual Disks

A fast initialization on a virtual disk overwrites the first and last 8 MB of the virtual disk, clearing any boot records or partition information. The operation takes only 2-3 seconds to complete and is recommended when you are recreating virtual disks. You can perform a fast initialization in the CMC.

NOTE: A BGI starts five minutes after the Fast Initialization is completed.

Physical Disk Roaming

Physical disk roaming is moving the physical disks from one backplane slot to another on the same controller. The controller automatically recognizes the relocated physical disks and logically places them in the virtual disks that are part of the disk group. You can perform disk roaming only when the system is turned off.

13

Image 13
Contents User’s Guide Page Contents Deploying The Shared Perc 8 Card Driver InstallationGetting help About The Shared Perc 8 Card Configurations of the Shared Perc 8 cardStorage Subsystem Compatibility Matrix at dell.com Specifications of a Shared Perc 8 cardPage Best Practices For Shared Perc Supported Operating SystemsRelated Documentation Contacting Dell Locating your system Service TagDocumentation Feedback Physical Disk Power Management Shared Perc 8 Card FeaturesConsistency Checks Virtual Disk InitializationBackground Initialization Of Virtual Disks Physical Disk RoamingFull Initialization Of Virtual Disks Fast Initialization Of Virtual DisksFastPath Using Physical Disk RoamingVirtual Disk Migration Migrating Virtual Disks If The Target System Is Turned Off Virtual Disk Cache PoliciesMigrating Virtual Disks If The Target System Is Turned On Write-Back Virtual Disk Write Cache PoliciesConditions Under Which Write-Back Is Employed Write-throughPhysical Disk Write Cache Policy Fault ToleranceConditions under which write-through is employed Virtual Disk Read Cache PoliciesPatrol Read Smart FeaturePhysical Disk Hot Swapping Physical disk failure detectionShared Perc 8 Card Cache Preservation Controller Failover Feature Battery Transparent Learn CycleConfiguring Multipath Support In VMWare Configuring Multipath Support In WindowsMultipath Support Multipath support in LinuxDeploying The Shared Perc 8 Card Installing a New Shared Perc 8 CardReplacing a Shared Perc 8 Card Removing The Shared Perc 8 Card Prerequisites For Removing The Shared Perc 8 CardRemoving and Installing the Shared Perc 8 Card Post-Installation Tasks For Shared Perc 8 Card Installing The Shared Perc 8 CardUpdating firmware Firmware installation or updateDriver Installation Installing Or Updating Windows Drivers For Shared Perc Installing Or Updating VMware Drivers For Shared Perc Installing Or Updating Linux Drivers For Shared PercManagement Applications For Shared Perc 8 Card Shared Perc 8 Card Boots Into Safe Mode TroubleshootingDegraded State Of Virtual Disks General IssuesShared Perc 8 Card Not Seen In Device Manager Unable to rebuild a fault tolerant virtual disk Physical disk issuesShared Perc 8 Cards Fail To Function Physical Disk In Failed StateMultiple Disks Become Inaccessible Fatal Error Or Data Corruption ReportedRebuilding a Failed Physical Disk Controller cache issues Virtual Disk Fails During Rebuild Using a Global Hot SparePhysical disk takes a long time to rebuild Smart Errors Source Disk Fails Auto Replacement Member ErrorsTarget Disk Fails General Disk FailsHard-Drive Indicators Hard-Drive Indicator PatternsDocumentation feedback Getting help