Toshiba C-DR0101 Setting Item Chart and Setting Procedures, Basic Setting Procedures

Page 11

6. SETTING ITEM CHART AND SETTING PROCEDURES

6.1. Basic Setting Procedures

The shaded item in the figure refers to the cursor position. 1. Enter the main menu screen.

Camera Display Screen

THU JAN/01/04 00:00:00

MENU key

Press key for 1 second or more

Main Menu Screen

MAIN MENU

PLAY SETTING CLOCK SETTING DISK SETTING REC SETTING

ON – SCREEN DISP SETTING KEY LOCK COMMUNICATION SETTING LOG DISPLAY

SYSTEM MAINTENANCE

2. Enter the setting screen.

 

 

MAIN

MENU

 

 

PLAY

SETTING

key

CLOCK SETTING

DISK

SETTING

 

 

REC

SETTING

or

ON – SCREEN DISP SETTING

KEY

LOCK

 

 

key

COMMUNICATION SETTING

LOG

DISPLAY

 

 

SYSTEM MAINTENANCE

 

 

 

 

SELECT key

Setting screen

REC SETTING

GENERAL REC SETTING TIMER REC SETTING ALARM REC SETTING

key

or key

REC SETTING

GENERAL REC SETTING TIMER REC SETTING

ALARM REC SETTING

3. Select the setting value.

ALARM REC SETTING

SELECT

ALARM

SETTING

[

 

VALID]

key

ALARM

IN MODE

[

 

EDGE]

PRE–ALARM

 

[20SEC]

 

 

ALARM

PERIOD

 

[10SEC]

 

 

POST–ALARM

 

[10SEC]

 

 

PICTURE

[LEVEL3]

 

 

AUDIO

 

 

[

ON]

 

 

REC INTERVAL

[1/30SEC]

 

 

BUZZER

 

 

[

ON]

 

 

ALARM

OUT

[DURING

REC]

key

or key

ALARM

REC SETTING

 

 

 

 

 

ALARM

SETTING

[

 

VALID]

ALARM

IN MODE

[

EDGE]

PRE–ALARM

 

 

[20SEC]

ALARM

PERIOD

 

 

[10SEC]

POST–ALARM

 

 

[10SEC]

PICTURE

[

 

 

LEVEL3]

AUDIO

 

 

 

[

ON]

REC INTERVAL

[1/30SEC]

BUZZER

 

 

 

[

ON]

ALARM

OUT

[DURING

REC]

 

 

 

 

 

 

 

+key

or

-key

ALARM

REC SETTING

 

 

 

 

 

ALARM

SETTING

[

 

VALID]

ALARM

IN MODE

[

EDGE]

PRE–ALARM

 

 

[20SEC]

ALARM

PERIOD

 

 

[10SEC]

POST–ALARM

 

 

[10SEC]

PICTURE

[

 

 

LEVEL1]

AUDIO

 

 

 

[

ON]

REC INTERVAL

[1/30SEC]

BUZZER

 

 

 

[

ON]

ALARM

OUT

[DURING

REC]

 

 

 

 

 

 

 

4. Confirm the selected setting value and return to the camera display screen.

 

 

REC SETTING

 

 

 

MAIN MENU

 

 

MENU

GENERAL REC SETTING

 

MENU

PLAY SETTING

 

MENU

key

 

key

 

TIMER REC SETTING

 

CLOCK SETTING

 

key

 

 

ALARM REC SETTING

 

 

 

DISK SETTING

 

 

 

 

 

 

 

REC SETTING

 

 

 

 

 

 

 

 

ON – SCREEN DISP SETTING

 

 

 

 

 

 

 

 

KEY LOCK

 

 

 

 

 

 

 

 

COMMUNICATION SETTING

 

 

 

 

 

 

 

 

LOG DISPLAY

 

 

 

 

 

 

 

 

SYSTEM MAINTENANCE

 

 

 

 

 

 

 

 

 

 

 

Camera Display Screen

THU JAN/ 01/ 04 00:00:00

11

Image 11
Contents 1CH Digital Video Recorder C-DR0100 Table of Contents Operation Digital Video Recorder Activation and Termination Modifications Ntsc version complies with Part 15 of the FCC RulesWhen Using the Recorder Safety PrecautionsSafety Symbol and Message Conventions When installing the RecorderGeneral Description FeaturesHandling Precautions Nomenclature and Functions Search Key Alarm Reset KeyDisk Full/Failure Indicator Disk Full Indicator Failure IndicatorAlarm Input Terminal Main Power SwitchRecording Stop Input Terminal Switcher Video Input Terminal Control Input/Output Terminal Alarm Reset Output TerminalSelect the setting value Setting Item Chart and Setting ProceduresBasic Setting Procedures Enter the setting screenSetting Item Setting Item ChartMain Menu Screen Individual Item SettingsPlayback Settings Time Sync Master / Slave Clock SettingsExample Disk SettingsSummer Time Daylight Saving Time Setting Mirroring HDD-A Recording SettingsREC Mode RE-REC / Stop / Series Disk Mode Play Mode NormalInternal Timer Recording Settings General Recording SettingsREC Pattern Timer Schedule Screen SettingsDate Daily / Weekly / Cancel TimeTable below Alarm Recording SettingsWith the or + key ScreenRecording period when input mode is set to Level About the Alarm Input ModeRecording period when input mode is set to Edge Screen Display Settings Key Lock Release Key LockRS232C Baud Communication SettingsNetwork Settings Ctrl Switcher Sync On / OFF / Time SyncLog Display General/ Timer Recording Logs General/ Timer Rec LogAlarm Recording Logs Alarm Rec Log Failure Logs System MaintenanceMenu Default Settings ALL Disk FormattingDR0101, C-DR0105 HDD-BRecorders Activation Digital Video Recorder Activation and TerminationRecorder’s Termination Operation After Power Failure RestorationWhen the Failure Screen Is Displayed When the Power Fails during RecordingRecording Priorities RecordingType of Recording Screen Display during RecordingPage Following keys are used in recording Keys to Be Used in RecordingTHU JAN 00 00 Screen Display during Playback PlaybackType of Playback Performing Various Playback Fanctions Keys to Be Used in PlaybackPerforming Playback Forward Block Playback and Reverse Block Playback Forward Frame Playback and Reverse Frame PlaybackAbout the Playback Start Position Basic Date/Time Search and Block Search Operations Search FunctionsKeys to Be Used in Searching Date/Time and Block SearchesBlock Search Operation Time Shift Search Connections to the Monitor TV When Using the 24V AC or 12V DC or AC Mains CameraConnections Preparations for ConnectionsExpansion System Series Recording Basic SystemConnection Examples Power Sync cameras cannot be used Connection to the Multi-switcherBasic System Combined with the C-MS91D Multi-switcher Master Expansion System Combined with the C-MS91D Multi-switcherRecording Time Table Recording Picture Quality SettingWhen using the C-DR0100 When using the C-DR0101Lebel 24KB 181 272 544 907 1361 2723 5447 8170 When using the C-DR0105Level 40KB 110 166 332 553 830 1660 3321 4982 8303 Level 32KB 137 206 412 687 1031 2063 4126 6189Rules of Overall Communications External Terminal SpecificationsRS-232C Communication Specifications RS-232C Connector Pin ArrangementRS-232C Communication Format Controller Digital Recorder RS-232C Communication Command Controller Digital RecorderKeys Commands Menu Setting Commands Search Menu Execution Command Menu Setting Content Request CommandLog Request Command Parameter RS-232C Communication Command Digital Recorder ControllerKey response command RS-232C Communication Format Digital Recorder ControllerMenu Setting Content Response Command About the Ethernet Terminal Log Content Response CommandSearch menu result command STX LEN Command Para DataRack Mounting Symptom Possible Cause Remedy If YOU Think There is a Failure Troubleshooting0dB = Specifications

C-DR0101 specifications

The Toshiba C-DR0101 is an innovative digital radiography (DR) system designed to enhance imaging capabilities in medical facilities. This advanced system combines Toshiba's cutting-edge technology with user-friendly features to improve diagnostic efficiency and patient care.

One of the standout features of the C-DR0101 is its proprietary flat-panel detector, which provides high-resolution images with exceptional detail. This detector offers a wide dynamic range, maximizing the quality of images captured in various clinical situations, from routine examinations to complex procedures. The system is equipped with advanced image processing algorithms that enhance image clarity and reduce noise, ensuring that healthcare professionals have access to accurate diagnostics.

The C-DR0101 is designed with ease of use in mind. Its intuitive user interface streamlines workflow, allowing radiologists and technicians to quickly select imaging protocols and adjust settings as needed. This user-friendly design not only saves time but also minimizes the learning curve for new operators. The system's compact footprint allows for easy integration into existing radiology departments, making it a versatile choice for various healthcare environments.

In terms of technology, the C-DR0101 utilizes wireless connectivity, which allows for more flexible positioning of the detector and reduces clutter in the exam room. This wireless feature also facilitates the seamless transfer of images to the hospital's information system, enabling quick access to patient data and images for timely decision-making.

Another key characteristic of the C-DR0101 is its enhanced patient safety features. The system is designed to minimize radiation exposure while still delivering high-quality images. This is achieved through advanced dose management technologies and customizable exposure settings tailored to the specific needs of each patient. This focus on patient safety aligns with the goals of modern healthcare to prioritize the well-being of patients while delivering effective diagnostic imaging solutions.

The Toshiba C-DR0101 stands out in the field of digital radiography through its combination of advanced imaging technology, user-friendly design, and commitment to patient safety. As healthcare continues to evolve, systems like the C-DR0101 play a crucial role in ensuring that medical professionals can provide prompt and accurate care.