Toshiba C-DR0101 Operation After Power Failure Restoration, When the Failure Screen Is Displayed

Page 28

8.2. When the Failure Screen Is Displayed:

Note

Avoid operating any key during a system check after the Standby key has been pressed. The failure indication shown in the figure at right could be displayed. In such cases, switch the power OFF and back ON again.

If the failure indication is still displayed even though the power is reactivated, format the hard disk. (Refer to p. 26; "Disk Formatting.")

If the failure indication does not disappear even though the disk is formatted, the disk ‘s failure may be the cause. Please contact your TOA dealer.

DISKS MAY HAVE FAILED .

PLEASE TURN POWER SWITCH OFF AND ON AGAIN .

8.3. Recorder’s Termination

1.Hold down the Standby key for at least 1 second.

All operations stop, placing the Recorder in standby mode.

Note

The Recorder’s operation can be terminated by holding down the Standby key for at least 1 second even while in General Recording mode. However, when the Recorder is next reactivated, the previous recording is not retained and the Recorder is put into Pause mode. Preprogrammed timer times are set revised even if the Recorder is terminated during the timer setting and activated again.

2.Set the Main Power switch to the OFF position. The Recorder’s power is switched off.

9. OPERATION AFTER POWER FAILURE RESTORATION

The Recorder’s set contents are never reset by power failures.

However, since the date and time are backed up by the built-in battery, if no power is supplied for a long period of time (1 month), they are reset. In such cases, perform the clock setting again.

9.1. When the Power Fails during Recording;

During General Recording

Recording is restarted when the power is restored.

During Alarm Recording

If an alarm input still continues when the power is restored, it is recognized as a new alarm input and recording is restarted. However, if no alarm exists, recording is not performed. Also, even if the power is restored within the set Alarm Recording time period or Post-alarm time period, recording is not restarted because there is no alarm signal.

During Internal Timer Recording

Timer operation is restarted if the power is restored within the set time period. If restored during Internal Timer Recording, the recording is restarted.

28

Image 28
Contents 1CH Digital Video Recorder C-DR0100 Table of Contents Operation Digital Video Recorder Activation and Termination Ntsc version complies with Part 15 of the FCC Rules ModificationsSafety Precautions Safety Symbol and Message ConventionsWhen installing the Recorder When Using the RecorderFeatures General DescriptionHandling Precautions Nomenclature and Functions Alarm Reset Key Disk Full/Failure Indicator Disk Full IndicatorFailure Indicator Search KeyMain Power Switch Recording Stop Input Terminal Switcher Video Input TerminalControl Input/Output Terminal Alarm Reset Output Terminal Alarm Input TerminalSetting Item Chart and Setting Procedures Basic Setting ProceduresEnter the setting screen Select the setting valueSetting Item Chart Setting ItemPlayback Settings Individual Item SettingsMain Menu Screen Clock Settings Time Sync Master / SlaveSummer Time Daylight Saving Time Setting Disk SettingsExample Recording Settings REC Mode RE-REC / Stop / SeriesDisk Mode Play Mode Normal Mirroring HDD-AGeneral Recording Settings Internal Timer Recording SettingsTimer Schedule Screen Settings Date Daily / Weekly / CancelTime REC PatternAlarm Recording Settings With the or + keyScreen Table belowRecording period when input mode is set to Edge About the Alarm Input ModeRecording period when input mode is set to Level Screen Display Settings Key Lock Key Lock ReleaseCommunication Settings Network SettingsCtrl Switcher Sync On / OFF / Time Sync RS232C BaudAlarm Recording Logs Alarm Rec Log General/ Timer Recording Logs General/ Timer Rec LogLog Display Menu Default Settings System MaintenanceFailure Logs Disk Formatting DR0101, C-DR0105HDD-B ALLDigital Video Recorder Activation and Termination Recorders ActivationOperation After Power Failure Restoration When the Failure Screen Is DisplayedWhen the Power Fails during Recording Recorder’s TerminationRecording Type of RecordingScreen Display during Recording Recording PrioritiesPage Keys to Be Used in Recording Following keys are used in recordingTHU JAN 00 00 Type of Playback PlaybackScreen Display during Playback Performing Playback Keys to Be Used in PlaybackPerforming Various Playback Fanctions Forward Frame Playback and Reverse Frame Playback Forward Block Playback and Reverse Block PlaybackAbout the Playback Start Position Search Functions Keys to Be Used in SearchingDate/Time and Block Searches Basic Date/Time Search and Block Search OperationsBlock Search Operation Time Shift Search When Using the 24V AC or 12V DC or AC Mains Camera ConnectionsPreparations for Connections Connections to the Monitor TVBasic System Expansion System Series RecordingConnection Examples Basic System Combined with the C-MS91D Multi-switcher Connection to the Multi-switcherPower Sync cameras cannot be used Expansion System Combined with the C-MS91D Multi-switcher MasterRecording Picture Quality Setting When using the C-DR0100When using the C-DR0101 Recording Time TableWhen using the C-DR0105 Level 40KB 110 166 332 553 830 1660 3321 4982 8303Level 32KB 137 206 412 687 1031 2063 4126 6189 Lebel 24KB 181 272 544 907 1361 2723 5447 8170External Terminal Specifications RS-232C Communication SpecificationsRS-232C Connector Pin Arrangement Rules of Overall CommunicationsKeys Commands RS-232C Communication Command Controller Digital RecorderRS-232C Communication Format Controller Digital Recorder Menu Setting Commands Log Request Command Menu Setting Content Request CommandSearch Menu Execution Command RS-232C Communication Command Digital Recorder Controller Key response commandRS-232C Communication Format Digital Recorder Controller ParameterMenu Setting Content Response Command Log Content Response Command Search menu result commandSTX LEN Command Para Data About the Ethernet TerminalRack Mounting If YOU Think There is a Failure Troubleshooting Symptom Possible Cause RemedySpecifications 0dB =

C-DR0101 specifications

The Toshiba C-DR0101 is an innovative digital radiography (DR) system designed to enhance imaging capabilities in medical facilities. This advanced system combines Toshiba's cutting-edge technology with user-friendly features to improve diagnostic efficiency and patient care.

One of the standout features of the C-DR0101 is its proprietary flat-panel detector, which provides high-resolution images with exceptional detail. This detector offers a wide dynamic range, maximizing the quality of images captured in various clinical situations, from routine examinations to complex procedures. The system is equipped with advanced image processing algorithms that enhance image clarity and reduce noise, ensuring that healthcare professionals have access to accurate diagnostics.

The C-DR0101 is designed with ease of use in mind. Its intuitive user interface streamlines workflow, allowing radiologists and technicians to quickly select imaging protocols and adjust settings as needed. This user-friendly design not only saves time but also minimizes the learning curve for new operators. The system's compact footprint allows for easy integration into existing radiology departments, making it a versatile choice for various healthcare environments.

In terms of technology, the C-DR0101 utilizes wireless connectivity, which allows for more flexible positioning of the detector and reduces clutter in the exam room. This wireless feature also facilitates the seamless transfer of images to the hospital's information system, enabling quick access to patient data and images for timely decision-making.

Another key characteristic of the C-DR0101 is its enhanced patient safety features. The system is designed to minimize radiation exposure while still delivering high-quality images. This is achieved through advanced dose management technologies and customizable exposure settings tailored to the specific needs of each patient. This focus on patient safety aligns with the goals of modern healthcare to prioritize the well-being of patients while delivering effective diagnostic imaging solutions.

The Toshiba C-DR0101 stands out in the field of digital radiography through its combination of advanced imaging technology, user-friendly design, and commitment to patient safety. As healthcare continues to evolve, systems like the C-DR0101 play a crucial role in ensuring that medical professionals can provide prompt and accurate care.