Toshiba C-DR0101 instruction manual Time Shift Search

Page 39

12.3. Time Shift Search

1.Press the Pause key on the playback screen to suspend playback.

2.Press the Search key.

The Time Shift Search screen is displayed, and the Pause key flashes.Pressing the Search key again returns the display to the playback pause screen.

3.Using the ( ) or ( ) key, change the time period to be shifted.The shift time period increases as the ( ) key is pressed, and decreases as the ( ) key is pressed. It can be set to a variable period of 1 – 60 minutes.

THU JAN / 01 / 04 00 : 00 : 00

SHIFT TIME CHANGE : /

SHIFTING

 

: – / +

CANCEL

 

: SEARCH

 

 

SHIFT: 10MIN

LEVEL3

1/60

A

4.Press the (+) or () key.

The (+) key advances the shift time period by the designated length of time, while the (–) key reverses the time period by the same designated length of time. If no image exists at the designated time, pressing the

(+) key displays the image following the designated time, while the image preceding the designated time is displayed if the () key is pressed.

5.Press the Search key to reset the Time Shift Search.

The display is temporarily stopped at the searched Time Shift screen.

6.Press the Pause key to begin playback of the searched image.

Note

Continuous or normal forward/reverse frame playback can also be performed even when the Time Shift Search screen is displayed (even while the Pause key is flashing).

If Time Shift Search operation exceeds the range of "Loop" playback during "Loop" playback, the "Loop" playback is reset, reverting to normal playback.

When the Time Shift Search function is operated within the "Loop" playback range:

Time Shift

Pause

 

Time Shift

 

 

 

 

Block

Block

Block

“Loop” playback

When the Time Shift Search function is operated beyond the "Loop" playback range:

Time Shift

Pause

Time Shift

 

 

 

 

 

 

 

 

Block

Block

Block

Playback operation on a time basis

39

Image 39
Contents 1CH Digital Video Recorder C-DR0100 Table of Contents Operation Digital Video Recorder Activation and Termination Modifications Ntsc version complies with Part 15 of the FCC RulesWhen Using the Recorder Safety PrecautionsSafety Symbol and Message Conventions When installing the RecorderGeneral Description FeaturesHandling Precautions Nomenclature and Functions Search Key Alarm Reset KeyDisk Full/Failure Indicator Disk Full Indicator Failure IndicatorAlarm Input Terminal Main Power SwitchRecording Stop Input Terminal Switcher Video Input Terminal Control Input/Output Terminal Alarm Reset Output TerminalSelect the setting value Setting Item Chart and Setting ProceduresBasic Setting Procedures Enter the setting screenSetting Item Setting Item ChartIndividual Item Settings Playback SettingsMain Menu Screen Time Sync Master / Slave Clock SettingsDisk Settings Summer Time Daylight Saving Time SettingExample Mirroring HDD-A Recording SettingsREC Mode RE-REC / Stop / Series Disk Mode Play Mode NormalInternal Timer Recording Settings General Recording SettingsREC Pattern Timer Schedule Screen SettingsDate Daily / Weekly / Cancel TimeTable below Alarm Recording SettingsWith the or + key ScreenAbout the Alarm Input Mode Recording period when input mode is set to EdgeRecording period when input mode is set to Level Screen Display Settings Key Lock Release Key LockRS232C Baud Communication SettingsNetwork Settings Ctrl Switcher Sync On / OFF / Time SyncGeneral/ Timer Recording Logs General/ Timer Rec Log Alarm Recording Logs Alarm Rec LogLog Display System Maintenance Menu Default SettingsFailure Logs ALL Disk FormattingDR0101, C-DR0105 HDD-BRecorders Activation Digital Video Recorder Activation and TerminationRecorder’s Termination Operation After Power Failure RestorationWhen the Failure Screen Is Displayed When the Power Fails during RecordingRecording Priorities RecordingType of Recording Screen Display during RecordingPage Following keys are used in recording Keys to Be Used in RecordingTHU JAN 00 00 Playback Type of PlaybackScreen Display during Playback Keys to Be Used in Playback Performing PlaybackPerforming Various Playback Fanctions Forward Block Playback and Reverse Block Playback Forward Frame Playback and Reverse Frame PlaybackAbout the Playback Start Position Basic Date/Time Search and Block Search Operations Search FunctionsKeys to Be Used in Searching Date/Time and Block SearchesBlock Search Operation Time Shift Search Connections to the Monitor TV When Using the 24V AC or 12V DC or AC Mains CameraConnections Preparations for ConnectionsExpansion System Series Recording Basic SystemConnection Examples Connection to the Multi-switcher Basic System Combined with the C-MS91D Multi-switcherPower Sync cameras cannot be used Master Expansion System Combined with the C-MS91D Multi-switcherRecording Time Table Recording Picture Quality SettingWhen using the C-DR0100 When using the C-DR0101Lebel 24KB 181 272 544 907 1361 2723 5447 8170 When using the C-DR0105Level 40KB 110 166 332 553 830 1660 3321 4982 8303 Level 32KB 137 206 412 687 1031 2063 4126 6189Rules of Overall Communications External Terminal SpecificationsRS-232C Communication Specifications RS-232C Connector Pin ArrangementRS-232C Communication Command Controller Digital Recorder Keys CommandsRS-232C Communication Format Controller Digital Recorder Menu Setting Commands Menu Setting Content Request Command Log Request CommandSearch Menu Execution Command Parameter RS-232C Communication Command Digital Recorder ControllerKey response command RS-232C Communication Format Digital Recorder ControllerMenu Setting Content Response Command About the Ethernet Terminal Log Content Response CommandSearch menu result command STX LEN Command Para DataRack Mounting Symptom Possible Cause Remedy If YOU Think There is a Failure Troubleshooting0dB = Specifications

C-DR0101 specifications

The Toshiba C-DR0101 is an innovative digital radiography (DR) system designed to enhance imaging capabilities in medical facilities. This advanced system combines Toshiba's cutting-edge technology with user-friendly features to improve diagnostic efficiency and patient care.

One of the standout features of the C-DR0101 is its proprietary flat-panel detector, which provides high-resolution images with exceptional detail. This detector offers a wide dynamic range, maximizing the quality of images captured in various clinical situations, from routine examinations to complex procedures. The system is equipped with advanced image processing algorithms that enhance image clarity and reduce noise, ensuring that healthcare professionals have access to accurate diagnostics.

The C-DR0101 is designed with ease of use in mind. Its intuitive user interface streamlines workflow, allowing radiologists and technicians to quickly select imaging protocols and adjust settings as needed. This user-friendly design not only saves time but also minimizes the learning curve for new operators. The system's compact footprint allows for easy integration into existing radiology departments, making it a versatile choice for various healthcare environments.

In terms of technology, the C-DR0101 utilizes wireless connectivity, which allows for more flexible positioning of the detector and reduces clutter in the exam room. This wireless feature also facilitates the seamless transfer of images to the hospital's information system, enabling quick access to patient data and images for timely decision-making.

Another key characteristic of the C-DR0101 is its enhanced patient safety features. The system is designed to minimize radiation exposure while still delivering high-quality images. This is achieved through advanced dose management technologies and customizable exposure settings tailored to the specific needs of each patient. This focus on patient safety aligns with the goals of modern healthcare to prioritize the well-being of patients while delivering effective diagnostic imaging solutions.

The Toshiba C-DR0101 stands out in the field of digital radiography through its combination of advanced imaging technology, user-friendly design, and commitment to patient safety. As healthcare continues to evolve, systems like the C-DR0101 play a crucial role in ensuring that medical professionals can provide prompt and accurate care.