Toshiba C-DR0101 Recording Settings, REC Mode RE-REC / Stop / Series, Disk Mode Play Mode Normal

Page 16

Setting Item

Setting Value

Contents

 

 

 

REC MODE

RE-REC / STOP / SERIES

RE-REC: Automatically deletes old recordings in chronological order to

(Recording Mode)

 

overwrite the hard disk.

 

 

STOP: Performs no further recording to save previously recorded data

 

 

if no available hard disk time remains.

 

 

The Disk Full indicator flashes red whenever less than 1 hour of

 

 

available hard disk time remains, and changes to steady ON

 

 

(Indecator lights red) if no available time remains.

 

 

Selecting "RE-REC" in the menu resets the Disk Full mode and

 

 

causes the Disk Full indicator to extinguish.

 

 

SERIES: The Recorder stops and sends out a signal from its rear panel-

 

 

mounted Disk Full Output terminal if no available hard disk time

 

 

remains. If the Recorder receives a signal at its Recording Start

 

 

input terminal when it is in Disk Full mode, the Disk Full mode is

 

 

reset, causing the Disk Full indicator to extinguish.

 

 

 

* The underlined contents are factory-preset values.

Note

Avoid mixing both Normal Recordings and Mirroring Recordings on the hard disk. If mixed, block advance during playback or search operations cannot be correctly performed during playback. Be sure to re-format the disk when changing the Disk Mode Setting. Note that all recording data are deleted when formatted. (Refer to p. 26; "Disk Formatting.")

Setting the Clock Setting’s Time Sync to "SLAVE" and the Recording Mode to "SERIES" places the Recorder in Disk Full mode and causes the Disk Full indicator to light. Perform this setting when using the Series Recording function. (Refer to p. 41; "Expansion System (Series Recording).")

When the Recording mode is set to "SERIES," timer program cannot be perfomed.

If the Disk Mode is changed, the Playback Mode changes as follows and the screen indicates that the Playback Mode has changed. (C-DR0101, C-DR0105)

DISK MODE

PLAY MODE

 

 

NORMAL

ALL

 

 

MIRRORING

HDD-A

 

 

The disk to be used is set to HDD-B if "HDD-B" is selected in the Playback Mode settings. To set to the "HDD-A" disk again, set the Disk mode to "MIRRORING."

About Mirroring Recording. (C-DR0101, C-DR0105)

Setting the Disk Mode to "MIRRORING" permits the same recording to be performed simultaneously on the two built-in hard disks. Should one of the two disks fail, the other disk will continue recording or playing back to ensure automatic backup. Be sure to first format both disks before performing Mirroring Recording to make their available recording times equal.

When a difference in available recording time between the two disk drives exists, recording can continue if one of the two disks becomes full, provided recording time remains available on the other disk. However, this will no longer be Mirroring Recording. The maximum available Mirroring Recording time can be checked by setting the remaining time display to "MIN."

7.5. Recording Settings

Set individual recording conditions for General Recording, Internal Timer Recording, and Alarm Recording.

Move the cursor with the ( ) or ( ) key, and display the selected setting screen with the Select key.

Confirm the selected setting with the Menu key, and return to the previous screen.

REC SETTING

GENERAL REC SETTING TIMER REC SETTING ALARM REC SETTING

16

Image 16
Contents 1CH Digital Video Recorder C-DR0100 Table of Contents Operation Digital Video Recorder Activation and Termination Ntsc version complies with Part 15 of the FCC Rules ModificationsSafety Precautions Safety Symbol and Message ConventionsWhen installing the Recorder When Using the RecorderFeatures General DescriptionHandling Precautions Nomenclature and Functions Alarm Reset Key Disk Full/Failure Indicator Disk Full IndicatorFailure Indicator Search KeyMain Power Switch Recording Stop Input Terminal Switcher Video Input TerminalControl Input/Output Terminal Alarm Reset Output Terminal Alarm Input TerminalSetting Item Chart and Setting Procedures Basic Setting ProceduresEnter the setting screen Select the setting valueSetting Item Chart Setting ItemPlayback Settings Individual Item SettingsMain Menu Screen Clock Settings Time Sync Master / SlaveSummer Time Daylight Saving Time Setting Disk SettingsExample Recording Settings REC Mode RE-REC / Stop / SeriesDisk Mode Play Mode Normal Mirroring HDD-AGeneral Recording Settings Internal Timer Recording SettingsTimer Schedule Screen Settings Date Daily / Weekly / CancelTime REC PatternAlarm Recording Settings With the or + keyScreen Table belowRecording period when input mode is set to Edge About the Alarm Input ModeRecording period when input mode is set to Level Screen Display Settings Key Lock Key Lock ReleaseCommunication Settings Network SettingsCtrl Switcher Sync On / OFF / Time Sync RS232C BaudAlarm Recording Logs Alarm Rec Log General/ Timer Recording Logs General/ Timer Rec LogLog Display Menu Default Settings System MaintenanceFailure Logs Disk Formatting DR0101, C-DR0105HDD-B ALLDigital Video Recorder Activation and Termination Recorders ActivationOperation After Power Failure Restoration When the Failure Screen Is DisplayedWhen the Power Fails during Recording Recorder’s TerminationRecording Type of RecordingScreen Display during Recording Recording PrioritiesPage Keys to Be Used in Recording Following keys are used in recordingTHU JAN 00 00 Type of Playback PlaybackScreen Display during Playback Performing Playback Keys to Be Used in PlaybackPerforming Various Playback Fanctions Forward Frame Playback and Reverse Frame Playback Forward Block Playback and Reverse Block PlaybackAbout the Playback Start Position Search Functions Keys to Be Used in SearchingDate/Time and Block Searches Basic Date/Time Search and Block Search OperationsBlock Search Operation Time Shift Search When Using the 24V AC or 12V DC or AC Mains Camera ConnectionsPreparations for Connections Connections to the Monitor TVBasic System Expansion System Series RecordingConnection Examples Basic System Combined with the C-MS91D Multi-switcher Connection to the Multi-switcherPower Sync cameras cannot be used Expansion System Combined with the C-MS91D Multi-switcher MasterRecording Picture Quality Setting When using the C-DR0100When using the C-DR0101 Recording Time TableWhen using the C-DR0105 Level 40KB 110 166 332 553 830 1660 3321 4982 8303Level 32KB 137 206 412 687 1031 2063 4126 6189 Lebel 24KB 181 272 544 907 1361 2723 5447 8170External Terminal Specifications RS-232C Communication SpecificationsRS-232C Connector Pin Arrangement Rules of Overall CommunicationsKeys Commands RS-232C Communication Command Controller Digital RecorderRS-232C Communication Format Controller Digital Recorder Menu Setting Commands Log Request Command Menu Setting Content Request CommandSearch Menu Execution Command RS-232C Communication Command Digital Recorder Controller Key response commandRS-232C Communication Format Digital Recorder Controller ParameterMenu Setting Content Response Command Log Content Response Command Search menu result commandSTX LEN Command Para Data About the Ethernet TerminalRack Mounting If YOU Think There is a Failure Troubleshooting Symptom Possible Cause RemedySpecifications 0dB =

C-DR0101 specifications

The Toshiba C-DR0101 is an innovative digital radiography (DR) system designed to enhance imaging capabilities in medical facilities. This advanced system combines Toshiba's cutting-edge technology with user-friendly features to improve diagnostic efficiency and patient care.

One of the standout features of the C-DR0101 is its proprietary flat-panel detector, which provides high-resolution images with exceptional detail. This detector offers a wide dynamic range, maximizing the quality of images captured in various clinical situations, from routine examinations to complex procedures. The system is equipped with advanced image processing algorithms that enhance image clarity and reduce noise, ensuring that healthcare professionals have access to accurate diagnostics.

The C-DR0101 is designed with ease of use in mind. Its intuitive user interface streamlines workflow, allowing radiologists and technicians to quickly select imaging protocols and adjust settings as needed. This user-friendly design not only saves time but also minimizes the learning curve for new operators. The system's compact footprint allows for easy integration into existing radiology departments, making it a versatile choice for various healthcare environments.

In terms of technology, the C-DR0101 utilizes wireless connectivity, which allows for more flexible positioning of the detector and reduces clutter in the exam room. This wireless feature also facilitates the seamless transfer of images to the hospital's information system, enabling quick access to patient data and images for timely decision-making.

Another key characteristic of the C-DR0101 is its enhanced patient safety features. The system is designed to minimize radiation exposure while still delivering high-quality images. This is achieved through advanced dose management technologies and customizable exposure settings tailored to the specific needs of each patient. This focus on patient safety aligns with the goals of modern healthcare to prioritize the well-being of patients while delivering effective diagnostic imaging solutions.

The Toshiba C-DR0101 stands out in the field of digital radiography through its combination of advanced imaging technology, user-friendly design, and commitment to patient safety. As healthcare continues to evolve, systems like the C-DR0101 play a crucial role in ensuring that medical professionals can provide prompt and accurate care.