Toshiba C-DR0101 Keys to Be Used in Recording, Following keys are used in recording

Page 31

10.3. The Keys to Be Used in Recording

The following keys are used in recording:

OUTPUT

TIMER REC

REVERSE

PAUSE PLAY

PLAY

SELECT

MENU SEARCH BUZZER

DISK FULL/

PLAY

STOP

 

 

 

 

STOP

FAILURE

 

 

 

 

 

 

VIDEO AUDIO

 

 

 

 

 

ALARM

 

 

FRAME

FRAME

 

BLOCK

RESET

DIGITAL VIDEO RECORDER

 

 

 

 

 

 

 

 

 

 

Timer Key

Recording Key

Buzzer Stop Key

10.4.Performing General Recording (Refer to p. 17; "General Recording Settings)

Note

Be sure to perform time and date settings before recording. (Refer to p. 14; "Clock Settings")

1.Press the Recording key (/) to start General Recording. When recording is started, the Recording key lights red.

If "DISP" has been selected in Screen Display Settings, setting data is displayed on the monitor and the Recording indication is displayed for recording status.

Note

When the Disk Setting Recording Mode has been set to "STOP" or "SERIES," the Disk Full indicator flashes if less than 1 hour of available hard disk time remains. If no available hard disk time remains, the Disk Full indicator changes to steady ON and recording stops.

THU JAN/ 01/ 04 00 : 00 : 00

REC

M : AB F

LEVEL3 1/60

2.Hold down the Recording key (/) for at least 1 second to stop recording. The illuminated Recording key extinguishes.

Note

If an alarm is activated during General Recording performance while in alarm standby mode, the General Recording is interrupted and switched over to Alarm Recording. The General Recording is automatically restored after Alarm Recording completion.

10.5.Performing Internal Timer Recording (Refer to p. 17; "Internal Timer Recording Settings)

Note

Be sure to perform date and time settings before recording. (Refer to p. 14; "Clock Settings".)

1.Press the Timer key.

The Digital Video Recorder is placed in Internal Timer Recording standby mode, and the Timer key lights green.

2.When the preset time is reached or if the key is pressed within the preset period, the Recording key lights red and recording is started. If "DISP" has been selected in Screen Display Settings, setting data is displayed on the monitor, and the "TIMER" indication is displayed for recording status.

THU JAN/ 01/ 04 00 : 00 : 00

TIMER

M : AB F

LEVEL3 1/60

31

Image 31
Contents 1CH Digital Video Recorder C-DR0100 Table of Contents Operation Digital Video Recorder Activation and Termination Modifications Ntsc version complies with Part 15 of the FCC RulesWhen Using the Recorder Safety PrecautionsSafety Symbol and Message Conventions When installing the RecorderGeneral Description FeaturesHandling Precautions Nomenclature and Functions Search Key Alarm Reset KeyDisk Full/Failure Indicator Disk Full Indicator Failure IndicatorAlarm Input Terminal Main Power SwitchRecording Stop Input Terminal Switcher Video Input Terminal Control Input/Output Terminal Alarm Reset Output TerminalSelect the setting value Setting Item Chart and Setting ProceduresBasic Setting Procedures Enter the setting screenSetting Item Setting Item ChartPlayback Settings Individual Item SettingsMain Menu Screen Time Sync Master / Slave Clock SettingsSummer Time Daylight Saving Time Setting Disk SettingsExample Mirroring HDD-A Recording SettingsREC Mode RE-REC / Stop / Series Disk Mode Play Mode NormalInternal Timer Recording Settings General Recording SettingsREC Pattern Timer Schedule Screen SettingsDate Daily / Weekly / Cancel TimeTable below Alarm Recording SettingsWith the or + key ScreenRecording period when input mode is set to Edge About the Alarm Input ModeRecording period when input mode is set to Level Screen Display Settings Key Lock Release Key LockRS232C Baud Communication SettingsNetwork Settings Ctrl Switcher Sync On / OFF / Time SyncAlarm Recording Logs Alarm Rec Log General/ Timer Recording Logs General/ Timer Rec LogLog Display Menu Default Settings System MaintenanceFailure Logs ALL Disk FormattingDR0101, C-DR0105 HDD-BRecorders Activation Digital Video Recorder Activation and TerminationRecorder’s Termination Operation After Power Failure RestorationWhen the Failure Screen Is Displayed When the Power Fails during RecordingRecording Priorities RecordingType of Recording Screen Display during RecordingPage Following keys are used in recording Keys to Be Used in RecordingTHU JAN 00 00 Type of Playback PlaybackScreen Display during Playback Performing Playback Keys to Be Used in PlaybackPerforming Various Playback Fanctions Forward Block Playback and Reverse Block Playback Forward Frame Playback and Reverse Frame PlaybackAbout the Playback Start Position Basic Date/Time Search and Block Search Operations Search FunctionsKeys to Be Used in Searching Date/Time and Block SearchesBlock Search Operation Time Shift Search Connections to the Monitor TV When Using the 24V AC or 12V DC or AC Mains CameraConnections Preparations for ConnectionsExpansion System Series Recording Basic SystemConnection Examples Basic System Combined with the C-MS91D Multi-switcher Connection to the Multi-switcherPower Sync cameras cannot be used Master Expansion System Combined with the C-MS91D Multi-switcherRecording Time Table Recording Picture Quality SettingWhen using the C-DR0100 When using the C-DR0101Lebel 24KB 181 272 544 907 1361 2723 5447 8170 When using the C-DR0105Level 40KB 110 166 332 553 830 1660 3321 4982 8303 Level 32KB 137 206 412 687 1031 2063 4126 6189Rules of Overall Communications External Terminal SpecificationsRS-232C Communication Specifications RS-232C Connector Pin ArrangementKeys Commands RS-232C Communication Command Controller Digital RecorderRS-232C Communication Format Controller Digital Recorder Menu Setting Commands Log Request Command Menu Setting Content Request CommandSearch Menu Execution Command Parameter RS-232C Communication Command Digital Recorder ControllerKey response command RS-232C Communication Format Digital Recorder ControllerMenu Setting Content Response Command About the Ethernet Terminal Log Content Response CommandSearch menu result command STX LEN Command Para DataRack Mounting Symptom Possible Cause Remedy If YOU Think There is a Failure Troubleshooting0dB = Specifications

C-DR0101 specifications

The Toshiba C-DR0101 is an innovative digital radiography (DR) system designed to enhance imaging capabilities in medical facilities. This advanced system combines Toshiba's cutting-edge technology with user-friendly features to improve diagnostic efficiency and patient care.

One of the standout features of the C-DR0101 is its proprietary flat-panel detector, which provides high-resolution images with exceptional detail. This detector offers a wide dynamic range, maximizing the quality of images captured in various clinical situations, from routine examinations to complex procedures. The system is equipped with advanced image processing algorithms that enhance image clarity and reduce noise, ensuring that healthcare professionals have access to accurate diagnostics.

The C-DR0101 is designed with ease of use in mind. Its intuitive user interface streamlines workflow, allowing radiologists and technicians to quickly select imaging protocols and adjust settings as needed. This user-friendly design not only saves time but also minimizes the learning curve for new operators. The system's compact footprint allows for easy integration into existing radiology departments, making it a versatile choice for various healthcare environments.

In terms of technology, the C-DR0101 utilizes wireless connectivity, which allows for more flexible positioning of the detector and reduces clutter in the exam room. This wireless feature also facilitates the seamless transfer of images to the hospital's information system, enabling quick access to patient data and images for timely decision-making.

Another key characteristic of the C-DR0101 is its enhanced patient safety features. The system is designed to minimize radiation exposure while still delivering high-quality images. This is achieved through advanced dose management technologies and customizable exposure settings tailored to the specific needs of each patient. This focus on patient safety aligns with the goals of modern healthcare to prioritize the well-being of patients while delivering effective diagnostic imaging solutions.

The Toshiba C-DR0101 stands out in the field of digital radiography through its combination of advanced imaging technology, user-friendly design, and commitment to patient safety. As healthcare continues to evolve, systems like the C-DR0101 play a crucial role in ensuring that medical professionals can provide prompt and accurate care.