Studer Innotec RCC-03, RCC-02 user manual Duration of the back-lighting, Backup of statistics

Page 20

Studer Innotec

Duration of the back-lighting {5009}

This configuration allows you to determine after how much time of inactivity the back-lighting will switch off.

Red back-lighting if the Xtender is OFF and if there is a fault {5026}

If the Xtender is stopped by a fault (battery undervoltage, overload, etc.) the back-lighting flashes red.

INACTIVITY PERIOD BEFORE RETURNING TO THE STANDARD DISPLAY {5010}

This configuration allows you to determine the time after which the display returns to the basic display if no key is pressed.

DURATION OF DISPLAY FOR QUICK MESSAGES {5011}

Messages of low importance are displayed for a limited period. This adjustment enables you to adapt this duration at your convenience.

ACOUSTIC ALARM {5027}

In the event of an alarm an acoustic signal is activated. You can always deactivate this signal by using this configuration.

USER LEVEL {5012}

The adjustment of the user level allows you to choose the access to the Xtender according to your level of expertise.

The INFO ONLY level may be selected by entering the code 460081. This level does not allow the Xtender configurations to be modified, it only allows information to be displayed on the system.

Use the INFO ONLY level after adjusting the configurations if the remote control is located in a public place or if it is accessible by people who are not authorised to carry out adjustments on your system.

You may change the level at any time to make new adjustments, by entering the appropriate code.

The BASIC level allows you to configure basic Xtender functions, limiting the field of actions to simple configurations. Please note that the incorrect adjustment of basic configurations may lead to the malfunctioning of the installation. This level is selected by default. To return to this level after a change, enter code 943274.

The EXPERT level allows access to more complex Xtender configurations and this level of usage may only be used with extensive specialist knowledge. To access the expert level, enter code 426468.

DRIVE THE REMOTE CONTROL TO THE USER LEVEL BASIC {5019}

You can with this option bring the remote control back to the level “user Basic”.

Use this function at the end of the system setting to go out of the EXPERT mode.

BACKUP AND RESTORING {5013}

The different options of this menu allow you to do a safety backup of your system or various actions in relation to the SD card.

Backup of statistics {5014}

Backup the data on the operation of your Xtender(s) using the SD card. The data are written into a file in CSV format, which can be reread in practically all spreadsheets and word processing

20

Image 20
Contents Studer Innotec Rue des Casernes CH 1950 Sion Studer Innotec Table of contents Maximum current of the AC source power sharing RCC Studer Innotec Product Recycling ForewordConventions Studer Innotec Contact Details Your RESELLER’ Contact DetailsWarranty Safety InstructionsAcceptance of the Software Licence and Updates Limitation of ResponsabilityStuder Innotec Controls and Indicators IntroductionModels Concerned SD CardConnection Series ConnectionDimensions RCC-02 RCC-03Adaptation to the Source Adjustment of the LanguageQuick Start Guide Adaptation to the Batterie Activation of the Function SMART-BOOST Basic Displays Activating and Deactivating the Combi Xtender Adjustment of the RCC Remote Control Adjustment of Date 5002 and TimeAdjustment of the Contrast Adjustment of the BACK-LIGHTINGBackup of statistics Duration of the back-lightingBackup of remote control configurations Backup of Xtender configurationsLoading the remote control configurations Loading the Xtender configurationsInformation on the Operating Mode of the Installation Display of the Parallel and THREE-PHASE Systems Alarm LOW Battery Voltage Stop Battery Voltage TOO LOWStop High Battery Voltage Event HistoryError Incorrect Input Frequency Error Input Voltage TOO HighError Input Voltage TOO LOW Stop OvertemperatureMessage Power Sharing Exceeded Transfer Prohibited Error Voltage AT AC OUTError Phase not Defined Stored EventsAdjustment of the Combi Xtender Basic configurations Maximum current of the AC source power sharingLocking Authorised inverterAutomatic restart Authorised chargerSmart boost authorised Authorised transferBattery cycle and charger Restore default configurationsRCC Studer Innotec Temperature correction coefficient Battery maintenance voltage floatingForce passage to floating mode Charge currentAbsorption phase Equalization phaseEqualization before absorption phase Equalization currentEqualization voltage Duration of equalizationInverter configurations Standby levelOutput voltage End of equalization activated by the currentCombi configurations Inverter-Charger Configurations for auxiliary contacts 1 and 2 1201 Simple functions Switching mode 1202Combination of events mode 1497 Battery undervoltage alarm 1226 Battery overvoltage 1227Temporal restrictions 1203 Contacts activated by an event 1455Contacts activated by the battery voltage 1245 Contacts activated by inverter power or smart boost 1257 Deactivate if the battery is in floating mode 1516Contacts activated with set schedules 1269 Dynamic compensation of the thresholds 1288Multi Xtender Phase integral modeExtended functions Xtender Remote ControlsInformation on the System Compatibility UpdatesUpdating Process Général USE INVERTER, Charger with Grid USE of a Limited Power SourceApplication Examples USE to Increase the Power on AN Existing Installation Load Shedding of the Second Priority LoadsAnnexe 1 List of Configuration Interdependencies AnnexesRCC Studer Innotec RCC

RCC-03, RCC-02 specifications

Studer Innotec, a renowned Swiss company in the field of power electronics, has made significant strides with its range of battery management systems, particularly the RCC-02 and RCC-03 models. These units are renowned for their cutting-edge technologies, impressive features, and superior performance in managing energy systems for both off-grid and hybrid applications.

The RCC-02 and RCC-03 Remote Control Displays provide end-users with an intuitive interface to monitor and control their energy systems seamlessly. With a clear and easy-to-read display, these units offer real-time data, allowing users to view essential information such as battery voltage, current, and state of charge. This vital information empowers users to make informed decisions regarding energy consumption and system management.

One of the standout features of the RCC-02 and RCC-03 models is their compatibility with a wide range of Studer Innotec products, including inverters and battery chargers. This versatility ensures seamless integration into existing systems, making it an ideal choice for both new installations and upgrades of existing systems.

Both models incorporate advanced communication technologies such as RS-232 and CAN-bus, allowing for easy data logging and system monitoring. This connectivity not only ensures that the user has access to real-time data but also enables remote monitoring and diagnostics, significantly enhancing the overall user experience.

Another characteristic that sets the RCC-02 and RCC-03 apart is their robust design. These units are engineered to withstand the harsh conditions often found in off-grid environments, ensuring reliability and durability over an extended lifespan. The thoughtful design also includes user-friendly controls, making it easy to configure settings and manage system parameters for a wide array of applications.

Energy efficiency is paramount in today's energy-conscious world, and the RCC-02 and RCC-03 are designed to optimize battery usage. By providing timely information about battery status and energy flow, these units assist users in maximizing the lifespan of their batteries and ensuring that their energy resources are used effectively.

In summary, Studer Innotec’s RCC-02 and RCC-03 Remote Control Displays are essential components for anyone looking to harness the power of reliable battery management systems. With their advanced technologies, user-friendly interfaces, and robust construction, they represent the cutting edge of energy management in both off-grid and hybrid applications. Whether for residential, commercial, or industrial use, these units deliver efficiency, reliability, and peace of mind to users.