Studer Innotec RCC-02, RCC-03 user manual Contacts activated by the battery voltage 1245

Page 41

RCC

Inverter or smart boost overload {1228} {1336}

Activates the contact in the event of an error due to excessive power in the inverter or the Smart Boost function. In the event that the inverter disconnects due to excess power and it is attempting to restart, the contact is not activated until the end of the attempts.

Overtemperature {1229} {1337}

Activates the contact in the event of overtemperature in the electronics or the transformer.

No Overtemperature alarm {1520} {1521}

Activates the auxiliary contact if the charger function is active. When the function Smart-Boost is running, the condition is not met to activate the contact.

Active charger {1231} {1339}

Activates the auxiliary contact if the charger function is active. When the smart boost function is operating, the condition for activating the contact is not fulfilled.

Active inverter {1232} {1340}

Activates the auxiliary contact if the inverter function is active.

Smart boost active {1233} {1341}

Activates the auxiliary contact if the smart boost function is active. For more information on the smart boost function, refer to the manual for the Xtender inverter/charger.

AC In present with fault {1234} {1342}

Activates the auxiliary contact if there is voltage present at the AC In input but this voltage does not fulfil the conditions for activating the transfer relay.

AC In present {1235} {1343}

Activates the auxiliary contact if a voltage is present at the AC In input. This condition is independent of the state of the transfer relay.

Transfer relay drawn {1236} {1344}

Activates the auxiliary contact if the transfer relay is drawn.

AC Out present {1237} {1345}

Activates the auxiliary contact if a voltage is present at the output of the Xtender inverter/charger.

Battery charging in bulk charge phase {1238} {1346}

Activate the auxiliary contact if the battery is in bulk charge phase.

Battery charging in absorption phase {1239} {1347}

Activates the auxiliary contact if the battery is in absorption phase. If the periodic extended absorption function is activated, the contact is also activated in this phase.

Battery charging in equalization phase {1240} {1348}

Activates the auxiliary contact if the battery is in equalization phase.

Battery charging in floating phase {1242} {1350}

Activates the auxiliary contact if the battery is in maintenance phase. If the extended reduced floating function is activated, the contact is also activated in this phase.

Contacts activated by the battery voltage {1245} {1353}

These configurations allow activation of the auxiliary contacts if the battery voltage passes below a selected voltage during a period that is configurable as well. Three voltages linked to three durations are configurable to activate the auxiliary contact.

41

Image 41
Contents Studer Innotec Rue des Casernes CH 1950 Sion Studer Innotec Table of contents Maximum current of the AC source power sharing RCC Studer Innotec Product Recycling ForewordConventions Your RESELLER’ Contact Details Studer Innotec Contact DetailsSafety Instructions WarrantyAcceptance of the Software Licence and Updates Limitation of ResponsabilityStuder Innotec Introduction Controls and IndicatorsModels Concerned SD CardSeries Connection ConnectionRCC-02 RCC-03 DimensionsAdaptation to the Source Adjustment of the LanguageQuick Start Guide Adaptation to the Batterie Activation of the Function SMART-BOOST Basic Displays Activating and Deactivating the Combi Xtender Adjustment of Date 5002 and Time Adjustment of the RCC Remote ControlAdjustment of the Contrast Adjustment of the BACK-LIGHTINGDuration of the back-lighting Backup of statisticsBackup of Xtender configurations Backup of remote control configurationsLoading the remote control configurations Loading the Xtender configurationsInformation on the Operating Mode of the Installation Display of the Parallel and THREE-PHASE Systems Stop Battery Voltage TOO LOW Alarm LOW Battery VoltageStop High Battery Voltage Event HistoryError Input Voltage TOO High Error Incorrect Input FrequencyError Input Voltage TOO LOW Stop OvertemperatureError Voltage AT AC OUT Message Power Sharing Exceeded Transfer ProhibitedError Phase not Defined Stored EventsAdjustment of the Combi Xtender Maximum current of the AC source power sharing Basic configurationsLocking Authorised inverterAuthorised charger Automatic restartSmart boost authorised Authorised transferRestore default configurations Battery cycle and chargerRCC Studer Innotec Battery maintenance voltage floating Temperature correction coefficientForce passage to floating mode Charge currentEqualization phase Absorption phaseEqualization current Equalization before absorption phaseEqualization voltage Duration of equalizationStandby level Inverter configurationsOutput voltage End of equalization activated by the currentCombi configurations Inverter-Charger Configurations for auxiliary contacts 1 and 2 1201 Simple functions Switching mode 1202Combination of events mode 1497 Battery overvoltage 1227 Battery undervoltage alarm 1226Temporal restrictions 1203 Contacts activated by an event 1455Contacts activated by the battery voltage 1245 Deactivate if the battery is in floating mode 1516 Contacts activated by inverter power or smart boost 1257Contacts activated with set schedules 1269 Dynamic compensation of the thresholds 1288Multi Xtender Phase integral modeExtended functions Xtender Remote ControlsInformation on the System Compatibility UpdatesUpdating Process Général USE INVERTER, Charger with Grid USE of a Limited Power SourceApplication Examples Load Shedding of the Second Priority Loads USE to Increase the Power on AN Existing InstallationAnnexes Annexe 1 List of Configuration InterdependenciesRCC Studer Innotec RCC

RCC-03, RCC-02 specifications

Studer Innotec, a renowned Swiss company in the field of power electronics, has made significant strides with its range of battery management systems, particularly the RCC-02 and RCC-03 models. These units are renowned for their cutting-edge technologies, impressive features, and superior performance in managing energy systems for both off-grid and hybrid applications.

The RCC-02 and RCC-03 Remote Control Displays provide end-users with an intuitive interface to monitor and control their energy systems seamlessly. With a clear and easy-to-read display, these units offer real-time data, allowing users to view essential information such as battery voltage, current, and state of charge. This vital information empowers users to make informed decisions regarding energy consumption and system management.

One of the standout features of the RCC-02 and RCC-03 models is their compatibility with a wide range of Studer Innotec products, including inverters and battery chargers. This versatility ensures seamless integration into existing systems, making it an ideal choice for both new installations and upgrades of existing systems.

Both models incorporate advanced communication technologies such as RS-232 and CAN-bus, allowing for easy data logging and system monitoring. This connectivity not only ensures that the user has access to real-time data but also enables remote monitoring and diagnostics, significantly enhancing the overall user experience.

Another characteristic that sets the RCC-02 and RCC-03 apart is their robust design. These units are engineered to withstand the harsh conditions often found in off-grid environments, ensuring reliability and durability over an extended lifespan. The thoughtful design also includes user-friendly controls, making it easy to configure settings and manage system parameters for a wide array of applications.

Energy efficiency is paramount in today's energy-conscious world, and the RCC-02 and RCC-03 are designed to optimize battery usage. By providing timely information about battery status and energy flow, these units assist users in maximizing the lifespan of their batteries and ensuring that their energy resources are used effectively.

In summary, Studer Innotec’s RCC-02 and RCC-03 Remote Control Displays are essential components for anyone looking to harness the power of reliable battery management systems. With their advanced technologies, user-friendly interfaces, and robust construction, they represent the cutting edge of energy management in both off-grid and hybrid applications. Whether for residential, commercial, or industrial use, these units deliver efficiency, reliability, and peace of mind to users.