Studer Innotec RCC-02, RCC-03 Warranty, Limitation of Responsability, Safety Instructions

Page 9

RCC

WARNINGS AND CAUTION

WARRANTY

Studer Innotec issues on this product, which they have manufactured and offered for sale, a two year warranty against any material defect or manufacturing fault from the date of despatch by an agreed Studer Innotec distributor.

Any warranty claim will be refused if it is not sent back to the point of sale, or another place indicated by Studer Innotec, in appropriate packaging and accompanied by a copy of the dated proof of purchase.

No warranty claims will be accepted for damage resulting from handling, usage or processing that does not explicitly appear in this manual.

Cases of damage arising from the following causes are notably excluded from the warranty: Inappropriate use

The presence of liquids in the device or oxidation resulting from condensation Damage resulting from falls or mechanical shocks

The opening or alteration of the RCC remote control, carried out without the explicit authorisation of Studer Innotec

Damage due to atmospheric surge voltage (lightning) Damage from transportation due to inappropriate packaging

LIMITATION OF RESPONSABILITY

The placement, commissioning, use, maintenance and servicing of the RCC remote control cannot be the subject of monitoring by Studer Innotec. For this reasons Studer Innotec assumes no responsibility and liability for damage, costs or losses resulting from an installation that does not conform to the instructions, defective functioning or deficient maintenance.

The use of Studer Innotec devices is the responsibility of the customer in all cases. This equipment is neither designed nor guaranteed to supply installations used for vital medical care nor any other critical installation carrying significant potential damage risks to people or the environment.

Studer Innotec does not assume any responsibility for the infringement of patent rights or other rights of third parties that result from using the devices.

The responsibility of Studer Innotec may not under any circumstances exceed the amount spent to purchase the product.

Studer Innotec reserves the right to make any modifications to the product without prior notification.

SAFETY INSTRUCTIONS

Carefully read the following safety instructions in order to avoid any injury or risk of damaging this product and those that are connected to it.

Only use the connection cable specified and supplied by Studer Innotec. Under no circumstances should you use a damaged cable. In case of doubt about the condition of this device, it should be inspected by a qualified technician.

Do not use the RCC remote control in a humid environment.

Do not use the RCC remote control in an explosive environment.

ACCEPTANCE OF THE SOFTWARE LICENCE AND UPDATES

By using the RCC remote control, you are accepting the terms and conditions of the following licence agreement. Please read this carefully.

Studer Innotec is granting a limited licence to use the software installed in this equipment in its executable binary format during the normal functioning of the product. The title, the property rights and the copyrights relating to this software, remain the property of Studer Innotec.

You acknowledge that the software is the property of Studer Innotec and that it is protected by copyright law according to the international copyright treaties.

You also acknowledge that the structure, organisation and software code are valuable commercial secrets belonging to Studer Innotec. You agree not to decompile, disassemble, alter or reverse either the unit or the engineering or make the software readable, irrespective of which part of the software, or to create any work whatever that is based on this software.

9

Image 9
Contents Studer Innotec Rue des Casernes CH 1950 Sion Studer Innotec Table of contents Maximum current of the AC source power sharing RCC Studer Innotec Foreword ConventionsProduct Recycling Your RESELLER’ Contact Details Studer Innotec Contact DetailsSafety Instructions WarrantyAcceptance of the Software Licence and Updates Limitation of ResponsabilityStuder Innotec Introduction Controls and IndicatorsModels Concerned SD CardSeries Connection ConnectionRCC-02 RCC-03 DimensionsAdjustment of the Language Quick Start GuideAdaptation to the Source Adaptation to the Batterie Activation of the Function SMART-BOOST Basic Displays Activating and Deactivating the Combi Xtender Adjustment of Date 5002 and Time Adjustment of the RCC Remote ControlAdjustment of the Contrast Adjustment of the BACK-LIGHTINGDuration of the back-lighting Backup of statisticsBackup of Xtender configurations Backup of remote control configurationsLoading the remote control configurations Loading the Xtender configurationsInformation on the Operating Mode of the Installation Display of the Parallel and THREE-PHASE Systems Stop Battery Voltage TOO LOW Alarm LOW Battery VoltageStop High Battery Voltage Event HistoryError Input Voltage TOO High Error Incorrect Input FrequencyError Input Voltage TOO LOW Stop OvertemperatureError Voltage AT AC OUT Message Power Sharing Exceeded Transfer ProhibitedError Phase not Defined Stored EventsAdjustment of the Combi Xtender Maximum current of the AC source power sharing Basic configurationsLocking Authorised inverterAuthorised charger Automatic restartSmart boost authorised Authorised transferRestore default configurations Battery cycle and chargerRCC Studer Innotec Battery maintenance voltage floating Temperature correction coefficientForce passage to floating mode Charge currentEqualization phase Absorption phaseEqualization current Equalization before absorption phaseEqualization voltage Duration of equalizationStandby level Inverter configurationsOutput voltage End of equalization activated by the currentCombi configurations Inverter-Charger Configurations for auxiliary contacts 1 and 2 1201 Switching mode 1202 Combination of events mode 1497Simple functions Battery overvoltage 1227 Battery undervoltage alarm 1226Temporal restrictions 1203 Contacts activated by an event 1455Contacts activated by the battery voltage 1245 Deactivate if the battery is in floating mode 1516 Contacts activated by inverter power or smart boost 1257Contacts activated with set schedules 1269 Dynamic compensation of the thresholds 1288Phase integral mode Extended functionsMulti Xtender Remote Controls Information on the SystemXtender Updates Updating ProcessCompatibility USE of a Limited Power Source Application ExamplesGénéral USE INVERTER, Charger with Grid Load Shedding of the Second Priority Loads USE to Increase the Power on AN Existing InstallationAnnexes Annexe 1 List of Configuration InterdependenciesRCC Studer Innotec RCC

RCC-03, RCC-02 specifications

Studer Innotec, a renowned Swiss company in the field of power electronics, has made significant strides with its range of battery management systems, particularly the RCC-02 and RCC-03 models. These units are renowned for their cutting-edge technologies, impressive features, and superior performance in managing energy systems for both off-grid and hybrid applications.

The RCC-02 and RCC-03 Remote Control Displays provide end-users with an intuitive interface to monitor and control their energy systems seamlessly. With a clear and easy-to-read display, these units offer real-time data, allowing users to view essential information such as battery voltage, current, and state of charge. This vital information empowers users to make informed decisions regarding energy consumption and system management.

One of the standout features of the RCC-02 and RCC-03 models is their compatibility with a wide range of Studer Innotec products, including inverters and battery chargers. This versatility ensures seamless integration into existing systems, making it an ideal choice for both new installations and upgrades of existing systems.

Both models incorporate advanced communication technologies such as RS-232 and CAN-bus, allowing for easy data logging and system monitoring. This connectivity not only ensures that the user has access to real-time data but also enables remote monitoring and diagnostics, significantly enhancing the overall user experience.

Another characteristic that sets the RCC-02 and RCC-03 apart is their robust design. These units are engineered to withstand the harsh conditions often found in off-grid environments, ensuring reliability and durability over an extended lifespan. The thoughtful design also includes user-friendly controls, making it easy to configure settings and manage system parameters for a wide array of applications.

Energy efficiency is paramount in today's energy-conscious world, and the RCC-02 and RCC-03 are designed to optimize battery usage. By providing timely information about battery status and energy flow, these units assist users in maximizing the lifespan of their batteries and ensuring that their energy resources are used effectively.

In summary, Studer Innotec’s RCC-02 and RCC-03 Remote Control Displays are essential components for anyone looking to harness the power of reliable battery management systems. With their advanced technologies, user-friendly interfaces, and robust construction, they represent the cutting edge of energy management in both off-grid and hybrid applications. Whether for residential, commercial, or industrial use, these units deliver efficiency, reliability, and peace of mind to users.