Studer Innotec RCC-02, RCC-03 user manual Rcc

Page 31

RCC

The bulk charge and floating phases cannot be deactivated. If the conditions for starting a new battery charge cycle have come together, the bulk charge phase starts immediately.

The battery cycle fits a large number of batteries by default, irrespective of whether they are gel batteries or not.

31

Image 31
Contents Studer Innotec Rue des Casernes CH 1950 Sion Studer Innotec Table of contents Maximum current of the AC source power sharing RCC Studer Innotec Conventions ForewordProduct Recycling Your RESELLER’ Contact Details Studer Innotec Contact DetailsLimitation of Responsability WarrantySafety Instructions Acceptance of the Software Licence and UpdatesStuder Innotec SD Card Controls and IndicatorsIntroduction Models ConcernedSeries Connection ConnectionRCC-02 RCC-03 DimensionsQuick Start Guide Adjustment of the LanguageAdaptation to the Source Adaptation to the Batterie Activation of the Function SMART-BOOST Basic Displays Activating and Deactivating the Combi Xtender Adjustment of the BACK-LIGHTING Adjustment of the RCC Remote ControlAdjustment of Date 5002 and Time Adjustment of the ContrastDuration of the back-lighting Backup of statisticsLoading the Xtender configurations Backup of remote control configurationsBackup of Xtender configurations Loading the remote control configurationsInformation on the Operating Mode of the Installation Display of the Parallel and THREE-PHASE Systems Event History Alarm LOW Battery VoltageStop Battery Voltage TOO LOW Stop High Battery VoltageStop Overtemperature Error Incorrect Input FrequencyError Input Voltage TOO High Error Input Voltage TOO LOWStored Events Message Power Sharing Exceeded Transfer ProhibitedError Voltage AT AC OUT Error Phase not DefinedAdjustment of the Combi Xtender Authorised inverter Basic configurationsMaximum current of the AC source power sharing LockingAuthorised transfer Automatic restartAuthorised charger Smart boost authorisedRestore default configurations Battery cycle and chargerRCC Studer Innotec Charge current Temperature correction coefficientBattery maintenance voltage floating Force passage to floating modeEqualization phase Absorption phaseDuration of equalization Equalization before absorption phaseEqualization current Equalization voltageEnd of equalization activated by the current Inverter configurationsStandby level Output voltageCombi configurations Inverter-Charger Configurations for auxiliary contacts 1 and 2 1201 Combination of events mode 1497 Switching mode 1202Simple functions Contacts activated by an event 1455 Battery undervoltage alarm 1226Battery overvoltage 1227 Temporal restrictions 1203Contacts activated by the battery voltage 1245 Dynamic compensation of the thresholds 1288 Contacts activated by inverter power or smart boost 1257Deactivate if the battery is in floating mode 1516 Contacts activated with set schedules 1269Extended functions Phase integral modeMulti Xtender Information on the System Remote ControlsXtender Updating Process UpdatesCompatibility Application Examples USE of a Limited Power SourceGénéral USE INVERTER, Charger with Grid Load Shedding of the Second Priority Loads USE to Increase the Power on AN Existing InstallationAnnexes Annexe 1 List of Configuration InterdependenciesRCC Studer Innotec RCC

RCC-03, RCC-02 specifications

Studer Innotec, a renowned Swiss company in the field of power electronics, has made significant strides with its range of battery management systems, particularly the RCC-02 and RCC-03 models. These units are renowned for their cutting-edge technologies, impressive features, and superior performance in managing energy systems for both off-grid and hybrid applications.

The RCC-02 and RCC-03 Remote Control Displays provide end-users with an intuitive interface to monitor and control their energy systems seamlessly. With a clear and easy-to-read display, these units offer real-time data, allowing users to view essential information such as battery voltage, current, and state of charge. This vital information empowers users to make informed decisions regarding energy consumption and system management.

One of the standout features of the RCC-02 and RCC-03 models is their compatibility with a wide range of Studer Innotec products, including inverters and battery chargers. This versatility ensures seamless integration into existing systems, making it an ideal choice for both new installations and upgrades of existing systems.

Both models incorporate advanced communication technologies such as RS-232 and CAN-bus, allowing for easy data logging and system monitoring. This connectivity not only ensures that the user has access to real-time data but also enables remote monitoring and diagnostics, significantly enhancing the overall user experience.

Another characteristic that sets the RCC-02 and RCC-03 apart is their robust design. These units are engineered to withstand the harsh conditions often found in off-grid environments, ensuring reliability and durability over an extended lifespan. The thoughtful design also includes user-friendly controls, making it easy to configure settings and manage system parameters for a wide array of applications.

Energy efficiency is paramount in today's energy-conscious world, and the RCC-02 and RCC-03 are designed to optimize battery usage. By providing timely information about battery status and energy flow, these units assist users in maximizing the lifespan of their batteries and ensuring that their energy resources are used effectively.

In summary, Studer Innotec’s RCC-02 and RCC-03 Remote Control Displays are essential components for anyone looking to harness the power of reliable battery management systems. With their advanced technologies, user-friendly interfaces, and robust construction, they represent the cutting edge of energy management in both off-grid and hybrid applications. Whether for residential, commercial, or industrial use, these units deliver efficiency, reliability, and peace of mind to users.