Studer Innotec RCC-02, RCC-03 user manual Adjustment of the Combi Xtender

Page 27

RCC

ADJUSTMENT OF THE COMBI XTENDER

GENERAL

The Xtender inverter/charger has been designed to ensure that all basic functions of an energy management system work completely independently. In its original version, no adjustment is usually required.

Nevertheless, in certain installation conditions, it may be necessary to adjust some operating configurations. This is why the RCC remote control gives access to the adjustment of many configurations and within a range largely exceeding the usual values. Use these adjustment options with care and only with due specialist knowledge. Changing configurations is not the responsibility of Studer Innotec. Please refer to the chapter on limitation of responsibility for more information on this topic.

CONFIGURATION ON A SYSTEM WITH SEVERAL XTENDERS

When there is a system to which several Xtenders are connected, the changing of a configuration is global. It will be applied to all the Xtenders connected together. To carry out adjustments on a single Xtender, it is necessary to remove the connection cables and only keep the connection between the remote control and the Xtender on which the different adjustment is being carried out. It is thereby possible to configure each Xtender of a system independently. Once the configuration has been carried out, the original connection can be re-established.

Note: If you have carried out an individual configuration, once a configuration has been changed, the system reconnected by the data connection cable modifies this configuration for all the Xtenders connected.

UTILISATION AND ACCESS LEVELS

The functions described below refer to the EXPERT level. Depending on the user level selected, access to all the functions may not be possible. Refer to the chapter on adjusting the user level of the remote control for more information on this subject.

PRE-DEFINED FUNCTIONS OF THE AUXILIARY RELAYS

The two auxiliary relays (dry contacts) of the inverter-charger Xtender are already programmed with factory settings and can be activated with various functions. They react to different signals. The factory settings depend on the Xtender models.

For more information on the auxiliary contacts pre-set functions, please see the inverter-charger Xtender manual.

Caution, if your installer or supplier has done pre-settings, these pre-set functions may have been changed.

To check the different programmings, use the function backup of the Xtender parameters on the SD card, described there above in this manual.

MENU

The Xtender configurations are divided into several categories:

Basic configurations

Battery and its charge cycle configurations

Inverter configurations

Combi configurations (inverter/charger)

First auxiliary contact configurations

Second auxiliary contact configurations

Auxiliary contact extended function configurations

Three-phase or parallel operation configurations

27

Image 27
Contents Studer Innotec Rue des Casernes CH 1950 Sion Studer Innotec Table of contents Maximum current of the AC source power sharing RCC Studer Innotec Foreword ConventionsProduct Recycling Your RESELLER’ Contact Details Studer Innotec Contact DetailsLimitation of Responsability WarrantySafety Instructions Acceptance of the Software Licence and UpdatesStuder Innotec SD Card Controls and IndicatorsIntroduction Models ConcernedSeries Connection ConnectionRCC-02 RCC-03 DimensionsAdjustment of the Language Quick Start GuideAdaptation to the Source Adaptation to the Batterie Activation of the Function SMART-BOOST Basic Displays Activating and Deactivating the Combi Xtender Adjustment of the BACK-LIGHTING Adjustment of the RCC Remote ControlAdjustment of Date 5002 and Time Adjustment of the ContrastDuration of the back-lighting Backup of statisticsLoading the Xtender configurations Backup of remote control configurationsBackup of Xtender configurations Loading the remote control configurationsInformation on the Operating Mode of the Installation Display of the Parallel and THREE-PHASE Systems Event History Alarm LOW Battery VoltageStop Battery Voltage TOO LOW Stop High Battery VoltageStop Overtemperature Error Incorrect Input FrequencyError Input Voltage TOO High Error Input Voltage TOO LOWStored Events Message Power Sharing Exceeded Transfer ProhibitedError Voltage AT AC OUT Error Phase not DefinedAdjustment of the Combi Xtender Authorised inverter Basic configurationsMaximum current of the AC source power sharing LockingAuthorised transfer Automatic restartAuthorised charger Smart boost authorisedRestore default configurations Battery cycle and chargerRCC Studer Innotec Charge current Temperature correction coefficientBattery maintenance voltage floating Force passage to floating modeEqualization phase Absorption phaseDuration of equalization Equalization before absorption phaseEqualization current Equalization voltageEnd of equalization activated by the current Inverter configurationsStandby level Output voltageCombi configurations Inverter-Charger Configurations for auxiliary contacts 1 and 2 1201 Switching mode 1202 Combination of events mode 1497Simple functions Contacts activated by an event 1455 Battery undervoltage alarm 1226Battery overvoltage 1227 Temporal restrictions 1203Contacts activated by the battery voltage 1245 Dynamic compensation of the thresholds 1288 Contacts activated by inverter power or smart boost 1257Deactivate if the battery is in floating mode 1516 Contacts activated with set schedules 1269Phase integral mode Extended functionsMulti Xtender Remote Controls Information on the SystemXtender Updates Updating ProcessCompatibility USE of a Limited Power Source Application ExamplesGénéral USE INVERTER, Charger with Grid Load Shedding of the Second Priority Loads USE to Increase the Power on AN Existing InstallationAnnexes Annexe 1 List of Configuration InterdependenciesRCC Studer Innotec RCC

RCC-03, RCC-02 specifications

Studer Innotec, a renowned Swiss company in the field of power electronics, has made significant strides with its range of battery management systems, particularly the RCC-02 and RCC-03 models. These units are renowned for their cutting-edge technologies, impressive features, and superior performance in managing energy systems for both off-grid and hybrid applications.

The RCC-02 and RCC-03 Remote Control Displays provide end-users with an intuitive interface to monitor and control their energy systems seamlessly. With a clear and easy-to-read display, these units offer real-time data, allowing users to view essential information such as battery voltage, current, and state of charge. This vital information empowers users to make informed decisions regarding energy consumption and system management.

One of the standout features of the RCC-02 and RCC-03 models is their compatibility with a wide range of Studer Innotec products, including inverters and battery chargers. This versatility ensures seamless integration into existing systems, making it an ideal choice for both new installations and upgrades of existing systems.

Both models incorporate advanced communication technologies such as RS-232 and CAN-bus, allowing for easy data logging and system monitoring. This connectivity not only ensures that the user has access to real-time data but also enables remote monitoring and diagnostics, significantly enhancing the overall user experience.

Another characteristic that sets the RCC-02 and RCC-03 apart is their robust design. These units are engineered to withstand the harsh conditions often found in off-grid environments, ensuring reliability and durability over an extended lifespan. The thoughtful design also includes user-friendly controls, making it easy to configure settings and manage system parameters for a wide array of applications.

Energy efficiency is paramount in today's energy-conscious world, and the RCC-02 and RCC-03 are designed to optimize battery usage. By providing timely information about battery status and energy flow, these units assist users in maximizing the lifespan of their batteries and ensuring that their energy resources are used effectively.

In summary, Studer Innotec’s RCC-02 and RCC-03 Remote Control Displays are essential components for anyone looking to harness the power of reliable battery management systems. With their advanced technologies, user-friendly interfaces, and robust construction, they represent the cutting edge of energy management in both off-grid and hybrid applications. Whether for residential, commercial, or industrial use, these units deliver efficiency, reliability, and peace of mind to users.