Eiki LC-XG400L owner manual Compliance, AC Power Cord for the United States and Canada

Page 9

Compliance

Federal Communications Commission Notice

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

Consult the dealer or an experienced radio/TV technician for help.

Use of shielded cable is required to comply with class B limits in Subpart B of Part 15 of FCC Rules.

Do not make any changes or modifications to the equipment unless otherwise specified in the instructions. If such changes or modifications should be made, you could be required to stop operation of the equipment.

Model Number (s)

: LC-XG400, LC-XG400L

Trade Name

: EIKI

Responsible party

: EIKI International, Inc.

Address

: 30251 Esperanza Rancho Santa Margarita CA 92688-2132 U.S.A.

Telephone No.

: 800-242-3454 (949-457-0200)

AC Power Cord Requirement

The AC Power Cord supplied with this projector meets the requirement for use in the country you purchased it.

AC Power Cord for the United States and Canada:

AC Power Cord used in the United States and Canada is listed by the Underwriters Laboratories

 

(UL) and certified by the Canadian Standard Association (CSA).

 

AC Power Cord has a grounding-type AC line plug. This is a safety feature to be sure that the plug

 

will fit into the power outlet. Do not try to defeat this safety feature. Should you be unable to insert

GROUND

the plug into the outlet, contact your electrician.

 

THE SOCKET-OUTLET SHOULD BE INSTALLED NEAR THE EQUIPMENT AND EASILY ACCESSIBLE..

Image 9
Contents Model LC-XG400 Features and Design Table of Contents Risk of Electric Shock Do not Open To the OwnerSafety Instructions Top Control Air CirculationPositioning Precautions Installing the Projector in Proper DirectionsTransporting the Projector Moving the ProjectorCompliance AC Power Cord for the United States and CanadaPart Names and Functions Front Back !1 !2Kensington Security Slot Rear Terminal 4Infrared Remote Receiver Back Reset buttonTop Control Remote Control 9RESET/ON/ALL-OFF switch 4P-TIMER button@0FOCUS button Adjust the focus p.30 @1NO Show button 3MENU buttonAdjustable Feet Remote Control Battery InstallationRemote Control Code Installation Positioning the Projector for LC-XG400Moving the Lens Lens Installation Removing the lensAttaching the lens to the projector Cables used for connection Connecting to a Computer Digital and Analog RGBConnecting to Video Equipment Video, S-Video Connecting to Video Equipment Component and RGB Scart Projector side AC outlet side Connecting the AC Power CordBasic Operation What is PIN code?Turning On the Projector Enter a PIN codeTurning Off the Projector How to Operate the On-Screen Menu Remote ControlOn-Screen Menu Menu Bar Operating with Projector Control Lens OperationInformation Sound Adjustment Direct OperationMenu Operation Operating with Remote Control Timer button No Show buttonKeystone button Laser Pointer Function Pointer FunctionSpotlight Presentation Pointer button Wireless Mouse OperationInput Selection Remote Control OperationInput Top Control OperationInput Menu Input Source SelectionRGB PC analog RGB Scart RGB PC digital Video ComponentVideo or S-Video Video System SelectionComponent AV System Menu Video or S-VideoComputer System Selection Computer AdjustmentSelecting Computer System Manually PC System MenuPC Adjust Menu Auto PC AdjustmentTo store adjustment parameters Auto PC AdjManual PC Adjustment To store the adjusted data To clear the adjusted dataImage Level Selection Image Level SelectionImage Menu Image Adjustment Image AdjustmentImage Adjust Menu Gamma SharpnessNoise reduction ProgressiveTo reset the adjusted data, select Reset and press Screen Adjustment Screen AdjustmentScreen Menu KeystoneScreen Size Adjustment Computer Signals For zooming in and out the images Digital zoom +Digital zoom Screen Size Adjustment Video, Component Signals Setting SettingSetting Menu Language PointerLogo Capture Logo Logo and Logo PIN code lock settingsLogo select CaptureChange the Logo PIN code lock setting Enter a Logo PIN codeChange the Logo PIN code Remote control Display On start Power managementFan control setting Fan controlKey lock Change the PIN code lock setting Change the PIN code lock settingPIN code lock Enter a PIN codeChange the PIN code Change the PIN codeTest pattern Lamp counterFactory default Factory defaultFilter counter Filter counterReinstall the filter into the projector properly Lamp Replacement Reset the lamp counterPOA-LMP116 Service Parts No 335 Lamp counter Resetting the Lamp CounterThen check the matters below Projector is shut down and all five indicators are blinkingCleaning the Projector Cabinet Cleaning the Projection LensProblem TroubleshootingNo power AppendixDuring the operation Setting does not remain after Auto PC adjustment functionTurning off power Power management function doesAppendix Input Menu TreeSystem InformationSetting PC Adjust ScreenProjector Condition Indicators and Projector ConditionResetting the counter Lamp Replace indicatorON-SCREEN Resolution Compatible Computer Specifications59.940 Technical Specifications Optional Parts PJ Link Notice USB Connector Series B Configurations of TerminalsTerminal Analog RGB Mini D-sub 15 pin Terminal Mini DIN 8-PINLogo PIN Code Lock No PIN Code Number MemoDimensions China Deutschland & ÖsterreichCanada Eastern Europe